Invacare SOLO2 TPO100B Service Manual Download Page 3

TABLE OF CONTENTS

Part No 1164898

3

SOLO

2

TABLE OF CONTENTS

SPECIAL NOTES ................................................................................ 4
TYPICAL PRODUCT PARAMETERS  .................................................... 5

Regulatory Listing .......................................................................................................................................7

SECTION 1—IMPORTANT SAFEGUARDS ............................................ 8

Operating Information...............................................................................................................................8
To Reduce The Risk Of Burns, Electrocution, Fire Or Injury To Persons...................................8
Radio Frequency Interference .................................................................................................................9

SECTION 2—COMPONENT REPLACEMENT ....................................... 10

Cleaning the Gross Particle Filter.........................................................................................................10
Replacing the Inlet Filter .........................................................................................................................11
Replacing the Patient Outlet Filter .......................................................................................................12
Replacement Parts....................................................................................................................................12

SECTION 3—CHECKING O

2

 PURITY ................................................. 13

SECTION 4—ADMINISTRATIVE SETTINGS SCREEN  ........................... 14

Accessing Administrative Settings Screen...........................................................................................14
Resetting Patient Hours ..........................................................................................................................14
Adjusting DC Power Limit .....................................................................................................................15
Toggling Auto Pulse .................................................................................................................................16

SECTION 5—TROUBLESHOOTING AND MAINTENANCE  ................... 17

Functional Test..........................................................................................................................................17
Checking Outlet HEPA Filter ................................................................................................................18
Checking Compressor Inlet Filter ........................................................................................................18
Checking Power Loss Alarm..................................................................................................................18
Troubleshooting Alarms .........................................................................................................................19
Error Codes...............................................................................................................................................20
Transportable Oxygen Concentrator 

Preventive Maintenance Record ..................................................................................................................23

LIMITED WARRANTY  ..................................................................... 24

Summary of Contents for SOLO2 TPO100B

Page 1: ...es in this manual MUST be performed by a qualified technician For more information regarding Invacare products parts and services please visit www invacare com SOLO2 Transportable Oxygen Concentrator...

Page 2: ...BLE TO UNDERSTAND THE WARNINGS CAUTIONS OR INSTRUCTIONS CONTACT A HEALTHCARE PROFESSIONAL DEALER OR TECHNICAL PERSONNEL BEFORE ATTEMPTING TO USE THIS EQUIPMENT OTHERWISE INJURY OR DAMAGE MAY OCCUR ACC...

Page 3: ...the Inlet Filter 11 Replacing the Patient Outlet Filter 12 Replacement Parts 12 SECTION 3 CHECKING O2 PURITY 13 SECTION 4 ADMINISTRATIVE SETTINGS SCREEN 14 Accessing Administrative Settings Screen 14...

Page 4: ...hat normally would not burn are easily ignited and burn with great intensity in oxygen enriched air Failure to observe this warning can result in severe fire property damage and cause physical injury...

Page 5: ...otected against dripping water in upright position AC and DC power only IPX2 Protected against dripping water in upright and tilted positions battery power only NO AP APG NOT suitable for use in the p...

Page 6: ...cc delivered per minute CONSERVER BREATH RATE CAPACITY Up to and including 35 BPM without reduction of bolus minute volume CONTINUOUS FLOW SETTINGS 0 5 through 3 0 LPM 0 psi 0 5 LPM increments All se...

Page 7: ...DC SUPPLY 95 F to 104 35 C to 40 C Unlimited use all settings all modes Unlimited use all settings with pulse mode Limited to 2 0 LPM or less with continuous mode EXTENDED TEMPERATURE RANGE USING BAT...

Page 8: ...e The Risk Of Burns Electrocution Fire Or Injury To Persons DO NOT come in contact with the concentrator while wet DO NOT place or store product where it can drop into water or other liquid DO NOT rea...

Page 9: ...omagnetic emissions permitted by the above standards To determine if the emissions from the Transportable Oxygen Concentrator are causing the interference turn the Transportable Concentrator Off If th...

Page 10: ...lorine based products ethylene chloride or oil based products Pine Sol Lestoil or any other harsh chemical agents Only use mild liquid dish detergent such as Dawn 1 Squeeze thumb tabs on filter cover...

Page 11: ...ps screw driver remove the retaining screw securing the inlet filter access door to unit DETAIL B 3 Remove inlet filter access door from unit 4 Locate existing inlet filter and remove DETAIL C 5 Insta...

Page 12: ...filter and turn counter clockwise to loosen DETAIL A 3 Remove patient outlet filter and o ring from unit DETAIL B 4 Install new patient o ring onto unit 5 Install patient outlet filter A Hand tighten...

Page 13: ...oncentrator Preventive Maintenance Record on page 23 1 Turn the unit On by pressing the On Off button 2 Adjust flow to 3 0 LPM continuous refer to owner s manual allow to run for a minimum of 8 minute...

Page 14: ...Hours NOTE For this procedure refer to FIGURE 4 1 1 Enter administrative settings screen DETAIL B Refer to Accessing Administrative Settings Screen on page 14 for this procedure 2 Locate the Patient H...

Page 15: ...ocedure 2 Locate the DC Power Limit setting DETAIL B A Press the Up Increase or Down Decrease button to highlight DC Power Limit setting B Press the Return Highlight button to relocate highlight bar t...

Page 16: ...to the adjustable setting on right side of screen 3 Press the Up Increase or Down Decrease button to toggle between ON or OFF 4 Save changes by pressing the Return Highlight button to relocate highli...

Page 17: ...ery bars on battery symbol that correspond to the battery and the charging icon if battery is not at 100 DETAIL B FIGURE 5 1 Functional Test 4 Turn the Transportable Oxygen Concentrator on by pressing...

Page 18: ...ximately 2 3 seconds Verify unit starts and allow unit to run for 30 seconds 15 Turn unit off to complete test Checking Outlet HEPA Filter NOTE Recommended to be replaced between patients 1 Turn unit...

Page 19: ...r O2 Sensor Fail Alarm This alarm centers on failure of the O2 sensor This alarm has no corrective action available to either the patient or the provider Accessing Alarm Codes To access the Alarm code...

Page 20: ...Temp HI LO Check ambient temp and blockage of air inlet outlet 2304 Warning Low O2 Purity Check ambient temp and blockage of air inlet outlet 2560 Alarm Low O2 Purity Check ambient temp and blockage...

Page 21: ...error 2832 Alarm ric Event queue full 2833 Alarm ric Event queue empty 2834 Alarm ric Time out heap full 2835 Alarm ric Time out not found 2836 Alarm ric Infinite null transitions 2837 Alarm ric Too...

Page 22: ...river i2c response time out 2861 Alarm Wait for V12 off time out 2862 Alarm Wait for V12 on time out 2863 Alarm Gpio exp driver wait to acquire i2c time out 2864 Alarm Battery controller i2c response...

Page 23: ...days 4 380 hours are equivalent to usage 24 hours per day 7 days per week for 6 months 26 280 hours are equivalent to usage 24 hours per day 7 days per week for 3 years Record Date Of Service Record...

Page 24: ...erland Tel 41 22 354 60 10 Fax 41 22 354 60 11 Canada 570 Matheson Blvd E Unit 8 Mississauga Ontario L4Z 4G4 Canada 800 668 5324 All rights reserved Trademarks are identified by and All trademarks are...