Invacare® Pronto™ M41 Series
1
Positive (+) battery terminal of left battery
2
Positive (+) battery cable
3
Negative (–) battery cable
4
Negative (–) battery terminal of right battery
5
Positive (+) battery terminal of right battery
6
Positive (+) battery cable
7
Connector to power module
8
Negative (–) battery cable
9
Negative (–) battery terminal of left battery
10
Fuse
Fig. 6-21
Connecting Battery Cables
•
Phillips screwdriver
1.
Position batteries into wheelchair. See
6.12.5 Replacing Batteries, page 43
2.
Connect POSITIVE (+) battery cable (2) to POSITIVE (+) battery terminal of left battery (1).
3.
Connect NEGATIVE (–) battery cable (3) to NEGATIVE (–) battery terminal of right battery (4).
4.
Connect POSITIVE (+) battery cable (6) to POSITIVE (+) battery terminal of right battery (5).
5.
Slide terminal caps (not shown) onto all battery terminals.
6.
Plug connector (7) into power module.
New batteries MUST be fully charged before using, otherwise life of batteries will be reduced.
Disconnecting Battery Cables
DANGER!
Risk of damage and injuries
Serious personal injury or damage may occur in case of an electrical short.
– The use of rubber gloves is recommended when working with batteries.
– Never allow any of your tools and/or battery cables to contact both battery terminals at the same time.
•
Phillips screwdriver
1.
Disconnect connector (7) from power module.
2.
Slide terminal caps (not shown) away from all battery terminals.
3.
Disconnect NEGATIVE (–) battery cable (8) from NEGATIVE (–) battery terminal of left battery (9).
4.
Disconnect POSITIVE (+) battery cable (2) from POSITIVE (+) battery terminal of left battery (1).
5.
Remove batteries from wheelchair. See
6.12.5 Replacing Batteries, page 43
.
Replacing Fuse
•
Phillips screwdriver
1.
Disconnect connector (7) from power module.
2.
Slide terminal caps (not shown) away from battery terminals (1) and (4).
3.
Disconnect POSITIVE (+) battery cable (2) from POSITIVE (+) battery terminal of left battery (1).
4.
Disconnect NEGATIVE (–) battery cable (3) from NEGATIVE (–) battery terminal of right battery (4).
5.
Replace harness with fuse (10).
6.
Install parts in reverse order.
42