V233 - 5016 - AB - Intratone Renovation intercom installation 

Page 9 / 15 

EQUIPMENT CONFIGURATION 

 

A) G

ENERAL POINTS

 

INTRATONE intercoms are mainly configured via the website 

www.intratone.info

.  

Nonetheless, some settings can only be changed on the spot: 

 

- Push button configuration. 
- Door opening time configuration. 
- Intercom volume. 

B) C

ONFIGURATION WITH A 

R

ESIDENTIAL CENTRAL UNIT 

03-0101 

(See central unit guide V233-5001-XX) 
 
 
For push button and time-delayed opening see the central unit 

“Door settings”

 menu. 

 
For the volume level, two choices are available to you in the “Intercom volume” menu: 

“Direct volume input”:  

Enter a value between 1 and 4 corresponding to the volume level. 

“Intercom adjustment”: 

This menu triggers a 15-minute counter. Throughout this time you can go to the intercoms 
connected to this central unit to adjust the volume level. 

Step 1: 

Enter the 

keypad code: 

12345678

” 

 

 

Step 2: 

The intercom automatically 

triggers  

“volume level adjustment”

 

which runs in a loop. 

 

 

Step 3: 

Confirm

  

the selected level  

by pressing the 

call button

  

 

on the intercom 

 

 

This procedure is valid during the 15 minutes of the counter. To exit this procedure, wait until 
the end of the counter or quit the “Intercom adjustment” menu. 
 

 

 

Volume level 
adjustment 

Summary of Contents for SPECIAL RENOVATION

Page 1: ...al time central units 2 to 4 doors ref 03 0101 HCEN12 1 door ref 03 0102 EEN CIC12 Product description The Video intercom with name scrolling is composed of A 12 key keypad and backlit braille LCD screen ø 16 mm Two scroll keys and one call key A proximity reader A miniature camera for use when making video calls Built in speech synthesis Call in progress Door open etc The intercom is available in...

Page 2: ...ON SCENARIOS 8 A FOR USE WITH AUDIO CALLS ONLY 8 B FOR USE WITH VIDEO CALLS 8 C CABLING SCENARIO FOR A GATE WITH 2 TYPES OF CENTRAL UNITS 8 D CABLING SCENARIO FOR A GATE PLUS A BUILDING 8 EQUIPMENT CONFIGURATION 9 A GENERAL POINTS 9 B CONFIGURATION WITH A RESIDENTIAL CENTRAL UNIT 03 0101 9 C CONFIGURATION WITH AN INTRACODE CENTRAL UNIT 03 0102 10 POST INSTALLATION CHECK 11 A ON THE INTERCOM 11 B C...

Page 3: ...V233 5016 AB Intratone Renovation intercom installation Page 3 15 DIMENSIONS AND FITTING A DIMENSIONS ...

Page 4: ...V233 5016 AB Intratone Renovation intercom installation Page 4 15 B BUILT IN WALL BOX DIMENSIONS ...

Page 5: ...V233 5016 AB Intratone Renovation intercom installation Page 5 15 C FITTING 1 2 3 4 ...

Page 6: ...on varistor supplied and calibrated for 12V Cablingessential See next page Page 7 Exit push button Electric lock or Magnet lock Relay protection varistor ESSENTIAL Power supply to the lock Jumper position NO for an electric lock NF for a magnet lock Power supply to the central unit 12 24V DC IMPORTANT The push button magnet lock or electric lock may also be connected to the central unit It is not ...

Page 7: ...ed pair 0 8mm 100 metres max between each item Power supply next to the central unit Video signal Twisted pair ESSENTIAL 02 0126 Power supply 12 24 DC 2A P B t o b e s e t a t N F S e e c e n t r a l u n i t g u i d e EEN M3G 03 0102 EEN CIC12 See central unit guide V233 5002 Cabling info Twisted cable 0 8 mm diameter 100 metres max between each item Power supply next to the central unit Video sig...

Page 8: ...F CENTRAL UNITS The red connection represents Video V V The black connection represents D D and A A D CABLING SCENARIO FOR A GATE PLUS A BUILDING It is essential to use a central unit 03 0101 with in our example an extension card Scenario Audio and Video calls from the gate From the entrance of the building only Audio calls are possible 4 2 6 6 6 Add an extension card doors 3 and 4 6 6 2 2 2 In th...

Page 9: ...me level two choices are available to you in the Intercom volume menu Direct volume input Enter a value between 1 and 4 corresponding to the volume level Intercom adjustment This menu triggers a 15 minute counter Throughout this time you can go to the intercoms connected to this central unit to adjust the volume level Step 1 Enter the keypad code 12345678 Step 2 The intercom automatically triggers...

Page 10: ...er Numerical keys for time input key for summer winter season selection Accept remote time YES key for YES or NO selection Door settings Door settings PB NO Time delay 05s key to select NO or Numerical keys for time delay input or key to Quit key to confirm Intercom volume Direct volume input Enables direct input via the keypad of the volume of the connected intercom INTERNET update request Reques...

Page 11: ...e push button Check door opening with a badge See Test procedure in the central unit guide C CALLS Check visitor to resident sound quality o Audio call o Video call Check that during the call the resident can open their door by pressing the key on their telephone See Test procedure in the central unit guide D 3G MODULE RECEPTION LEVEL With your intercom it is possible to see the reception level fo...

Page 12: ...ght up Incorrect cabling on and or terminal blocks Check cabling between the central unit and the intercom When a badge is presented the LED of the reader lights up green but the door does not open Central unit relays not working Cable to the door Check if the relay is stuck Check cabling between the central unit and the door If the intercom says Call in progress but the resident cannot hear the v...

Page 13: ...one network standards TS 103 021 and TR 103 000 Cabling The cables connected to the central unit must not be close to other power sources mains power supply for example Operating guarantees The intercom is guaranteed within a temperature range of 20 C to 70 C and a level of relative humidity not exceeding 70 End of life recycling of the product The intercom and its accessories must not be discarde...

Page 14: ...V233 5016 AB Intratone Renovation intercom installation Page 14 15 B CERTIFICATES ...

Page 15: ...V233 5016 AB Intratone Renovation intercom installation Page 15 15 ...

Reviews: