V233 - 5016 - AB - Intratone Renovation intercom installation
Page 6 / 15
WIRING
A) G
ENERAL POINTS
B)
C
ONNECTION OF THE ELECTRIC LOCK
/
MAGNET LOCK AND THE PUSH BUTTON
- Twisted pairs
– Diameter: 0.8 – Max distance 100 metres
-
Video will only work if the intercom is fitted with a 3G module.
- Maximum
allowable
voltage on the relay of the intercom / central unit:
42V AC or 60V DC
-
Relay protection varistor supplied and calibrated for
12V
.
Cabling
essential
.
See next page (Page 7)
Exit push
button
Electric
lock
or
Magnet
lock
Relay protection varistor
ESSENTIAL
Power supply
to the lock
Jumper position:
- NO
for
an
electric
lock
- NF
for
a
magnet lock
Power supply
to the central
unit
12/24V DC
IMPORTANT
- The push button, magnet lock or electric
lock may also be connected to the central
unit.
It is not therefore necessary to cable
them to the intercom.
FOR THEIR CABLING, SEE THE CENTRAL
UNIT GUIDE.
IN THE CASE OF CABLING THE DOOR / PUSH BUTTON
TO THE INTERCOM
CABLING ESSENTIAL