EN : What is the failure ?
How to solve the problem!
Message on display: "Communication fault"
- Check the wiring between the block, the board and the
central unit: D + / D-
- The display must indicate the greeting.
Keys and or LCD screen not backlit
- Bad wiring on + and or - terminal blocks
Backlit keys while the display is not (or vice versa) Contact our technical services
When passing a badge, the LED of the reader
turns green, but the door does not open.
- Relay of the central does not work.
- Check wiring between the control panel and the door
The interphone says "Call in progress" but the
resident does not hear the visitor
Review A + / A- wiring
The platinum says "Call impossible" without call
tone
Check wiring to the block and leds level
Phone network not available
The resident does not see the visitor in his phone -Check wiring V + / V-
Warranty operating guarantees:
The renovation video intercom is guaranteed within a temperature range of -20°C and +60°C and at a relative
humidity level not exceeding 70%.
It must be installed according to the Top/Bottom directions given in these instructions and on the device.
The installation must be carried out by qualified personnel with the necessary knowledge for a safe assembly of the
equipment.
This kit includes the necessary elements to ensure a safe installation of the equipment.
End-of-life recycling of the product:
The renovation video intercom and its accessories must not be discarded with unsorted municipal waste,
but must be disposed of via the WEEE (Waste Electrical and Electronic Equipment) collection and recycling
system.
Simplified declaration of conformity
The undersigned, COGELEC, declares that access control type radio equipment for collective housing is
in compliance with Directive 2014/53 / EU (RED).The full text of the EU declaration of conformity is
available at the following internet address:
www.intratone.fr/documentation
Summary of Contents for 02-0126
Page 2: ...EU V233 5016 BA 2 16 AUDIO CALL APPEL AUDIO AUDIOANRUF AUDIO CALL LLAMADA AUDIO ...
Page 3: ...EU V233 5016 BA 3 16 VIDEO CALL APPEL VIDEO VIDEOANRUF VIDEO CALL LLAMADA VIDEO ...
Page 4: ...EU V233 5016 BA 4 16 X 1 X 1 X 1 Ref 02 0126 02 0135 02 0138 ...
Page 5: ...EU V233 5016 BA 5 16 Montage Fitting Montage Montage Montaje 1 2 3 ...
Page 6: ...EU V233 5016 BA 6 16 03 0102 VENTOUSE MAGNET LOCK GACHE ELECTRIC LOCK Ø 8 10 2m min 100m max ...
Page 7: ...EU V233 5016 BA 7 16 03 0101 VENTOUSE MAGNET LOCK GACHE ELECTRIC LOCK Ø 8 10 2m min 100m max ...