5 Order codes 

 

Code 

Description 

IA-N24 

Digital panel meter 

 

Kind of input: 

 

standard: voltage, current 

 

temperature: thermocouples, resistance thermometers 

 

AC signals 

 

DC signals: high voltage and high current 

 

 

Input 

 

 

see table 1 

 

 

 

Power supply: 

 

 

 

230 V AC 

 

 

 

110 V AC 

 

 

 

24 V AC 

 

 

 

85…253 V AC/DC with supply output 24 V/30 mA* 

 

 

 

20…40 V AC/DC with supply output 24 V/30 mA* 

 

 

 

 

Unit 

 

 

 

 

XX 

see table 2 

 

 

 

 

 

Version 

 

 

 

 

 

00 

standard 

 

 

 

 

 

NS 

non-standard settings (please see example) 

 

 

 

 

 

XX 

custom-made** 

 

 

 

 

 

 

Language 

 

 

 

 

 

 

English 

 

 

 

 

 

 

other** 

 

 

 

 

 

 

 

Certification 

 

 

 

 

 

 

 

without additional quality inspection certificate 

 

 

 

 

 

 

 

with additional quality inspection certificate 

 

 

 

 

 

 

 

On request** 

 

 

 

 

 

 

 

 

 
 

IA-N24 

 

 

 

 

 

 

 

 

*only for N24S and N24T 
**Please contact manufacturer 

 

Table 1: Input signals 
Code 

N24S 

N24T 

N24Z 

N24H 

0…20 mA 

Pt100: -50…150 

°C 

100 V AC 

 100 V DC 

4…20 mA 

Pt100: -50…400 

°C 

250 V AC 

 250 V DC 

0…60 mV 

Thermocouple J 

400 V AC 

 400 V DC 

0…10 mV 

Thermocouple K 

1 A AC 

 1 A DC 

 60 V 

 

5 A AC 

5 A DC 

 10 V 

 

20…500 Hz 

0…100 V DC 

 

 

 

0…250 V DC 

 
 

Table 2: Unit codes 

Code 

Unit 

Code 

Unit 

Code 

Unit 

00 

without 

06 

mA 

12 

bar 

01 

°C 

07 

kA 

13 

kPa 

02 

08 

kV 

14 

MPa 

03 

09 

Hz 

XX 

On order** 

04 

10 

turns 

05 

mV 

11 

rpm 

 

**Please contact the manufacturer 

Summary of Contents for IA-N248

Page 1: ...THE EXPERT IN LEVEL AND FLOW Accessories Digital Panel Meter IntraDigit Series IA N24 Technical Information 02 2011...

Page 2: ...cal Information Intra Automation 1 Intra Automation Technical Information 02 2011 Technical details subject to be changed without notice For comments regarding this brochure please contact info intra...

Page 3: ...ation Technical Information IA N24 2 IA N24 IntraDigit Digital Panel Meter List of Contents Chapt Title Page 1 Features 3 2 Application Example 3 3 Technical details 4 4 Electrical Connection 4 5 Orde...

Page 4: ...grammer Precision of displayed results decimal point measurement averaging time recounting of indications individual characteristic automatic or manual compensation temperature of cold ends for J K or...

Page 5: ...f range 1 digit Additional error from ambient temperature changes 50 of basic error IA N24H 0 100 120 V DC 0 250 275 V DC 120 100 100 120 VDC 300 250 250 300 VDC 600 400 400 600 VDC Input resistance 2...

Page 6: ...nnection of the N24Z and N24H meters for voltage measurement frequency only N24Z Electrical connection of the N24Z and N24H meters for current measurement Connections of N24T measuring inputs Resistan...

Page 7: ...e XX custom made Language E English X other Certification 0 without additional quality inspection certificate 1 with additional quality inspection certificate X On request IA N24 only for N24S and N24...

Page 8: ...int 000 0 for I U Averaging time 1 s Upper overflow of measurement 9999 Lower overflow of measurement 1999 Individual characteristic enabled Parameter a of the individual characteristic 5 Parameter b...

Page 9: ...for industrial measurement tasks For more information please contact us contact details on the backside of this brochure Flow measurement Itabar Flow Sensor IntraSonic IS210 Ultrasonic Flow Meter Lev...

Page 10: ...BENELUX Intra Automation GmbH B V Intra Automation HTP Otto Hahn Str 20 PO Box 10 41515 Grevenbroich 4730 AA Oudenbosch GERMANY THE NETHERLANDS 49 0 21 81 7 56 65 0 31 0 165 32 22 01 49 0 21 81 6 44...

Reviews: