background image

IA-N24 Technical 

Information 

Intra-Automation 

 

 

 

- 5 - 

 

4 Connecting diagrams 

 

 

Electrical connection of the 

N24S

 meter 

 

Electrical connection of the 

N24T

 meter 

 

Electrical connection of the 

N24Z

 and 

N24H

 meters for voltage measurement (frequency: only 

N24Z

 

Electrical connection of the 

N24Z

 and 

N24H

 meters for current measurement 

 

Connections of N24T measuring inputs 

 

 

 

Resistance thermometer in a 
two-wire system with manual 

compensation 

Resistance thermometer in a 

three-wire-system with 

automatic compensation 

Thermocouple of J or K type 

 

Summary of Contents for IA-N248

Page 1: ...THE EXPERT IN LEVEL AND FLOW Accessories Digital Panel Meter IntraDigit Series IA N24 Technical Information 02 2011...

Page 2: ...cal Information Intra Automation 1 Intra Automation Technical Information 02 2011 Technical details subject to be changed without notice For comments regarding this brochure please contact info intra...

Page 3: ...ation Technical Information IA N24 2 IA N24 IntraDigit Digital Panel Meter List of Contents Chapt Title Page 1 Features 3 2 Application Example 3 3 Technical details 4 4 Electrical Connection 4 5 Orde...

Page 4: ...grammer Precision of displayed results decimal point measurement averaging time recounting of indications individual characteristic automatic or manual compensation temperature of cold ends for J K or...

Page 5: ...f range 1 digit Additional error from ambient temperature changes 50 of basic error IA N24H 0 100 120 V DC 0 250 275 V DC 120 100 100 120 VDC 300 250 250 300 VDC 600 400 400 600 VDC Input resistance 2...

Page 6: ...nnection of the N24Z and N24H meters for voltage measurement frequency only N24Z Electrical connection of the N24Z and N24H meters for current measurement Connections of N24T measuring inputs Resistan...

Page 7: ...e XX custom made Language E English X other Certification 0 without additional quality inspection certificate 1 with additional quality inspection certificate X On request IA N24 only for N24S and N24...

Page 8: ...int 000 0 for I U Averaging time 1 s Upper overflow of measurement 9999 Lower overflow of measurement 1999 Individual characteristic enabled Parameter a of the individual characteristic 5 Parameter b...

Page 9: ...for industrial measurement tasks For more information please contact us contact details on the backside of this brochure Flow measurement Itabar Flow Sensor IntraSonic IS210 Ultrasonic Flow Meter Lev...

Page 10: ...BENELUX Intra Automation GmbH B V Intra Automation HTP Otto Hahn Str 20 PO Box 10 41515 Grevenbroich 4730 AA Oudenbosch GERMANY THE NETHERLANDS 49 0 21 81 7 56 65 0 31 0 165 32 22 01 49 0 21 81 6 44...