Technical specifications
INTORQ | BA 14.0214 | 10/2019
15
4
Technical specifications
4.1
Possible applications of the INTORQ spring-applied brake
¾
Degree of protection:
– The brake is designed for operation under the environmental conditions that apply to IP54 protec-
tion. Because of the numerous possibilities of using the brake, it is still necessary to check the func-
tionality of all mechanical components under the corresponding operating conditions.
¾
Ambient temperature:
– -20 °C to +40 °C (Standard)
4.2
Rated data
Fig. 2:
Air gap measurement
Size
Air gap
Permissible
wear distance
Rotor thickness
Mass of stator
s
LN
+0.06/-0.08
s
Lmax
Min.
Max.
m
[mm]
[mm]
[mm]
[mm]
[mm]
[kg]
17R
0.4
0.6
0.2
12.7
13.0
12.4
18R
19.2
19R
22.5
20R
26.5
22R
31.0
25R
41.5
28R
0.5
0.8
0.3
12.6
55.5
Tab. 1:
Rated data for air gap specifications