background image

(17PO)  AP619D/AP619DP-22 ELECTRIC PUMP  ENGLISH  4.875” X 7.25”  12/04/2021

English

17PO

READ AND SAVE THESE INSTRUCTIONS

Page 6

©2021 Intex Marketing ltd. - Intex Development Co. ltd. - Intex Recreation Corp. All rights reserved/Tous droits réservés/Todos los derechos 

reservados/Alle Rechte vorbehalten. Printed in China/Imprimé en Chine/Impreso en China/gedruckt in China.

®™ Trademarks used in some countries of the world under license from/®™ Marques utilisées dans certains pays sous licence de/Marcas registradas 

utilizadas en algunos países del mundo bajo licencia de/Warenzeichen verwendet in einigen Ländern der Welt in Lizenz von/I

ntex Marketing ltd. to/à/

a/an Intex Development Co. ltd., Hong Kong & Intex Recreation Corp., P.O. Box 1440, long Beach, CA 90801

 • Distributed in the European Union 

by/Distribué dans l’Union Européenne par/Distribuido en la unión Europea por/Vertrieb in der Europäischen Union durch/

Intex Trading B.V., Venneveld 

9, 4705 RR Roosendaal – The Netherlands        

                             

www.intexcorp.com

PROBlEM

        

CAUSE

SOlUTION

Air leakage

between internal air

pump and the pump

holder frame

• Pump not securely

  attached.

• Pump O-ring is

  dirty.

• Internal airbed

  beam threads are

  caught between

  the internal air

  pump and the

  pump holder frame.

• Pump O-ring is

  twisted and/or

  damaged.

• While holding the pump outer rim, push in and 

  turn the pump fully clockwise until the two side 

  tabs lock into place.

• 

Remove the pump from the airbed, remove 

  the O-ring from the pump and clean it with 

  water. Carefully replace the O-ring back to the 

  pump as to prevent dust, lint from sticking onto 

  the O-ring again. Also make sure the pump 

  holder frame inner wall is free from dust, hair 

  or lint.

• Remove the internal air pump and carefully 

  replace the pump back making sure the internal 

  airbed beam threads are away from the pump 

  holder frame.

• Remove the pump from the airbed, make sure 

  the O-ring is not damaged and/or twisted. 

  Realign the O-ring or replace a new O-ring. 

  Contact Intex service center for replacement.

Air pump does not

work 

• Not connected to

  an electrical outlet

  socket.

• Pump motor

  thermo-protector

  activated.

• Internal air pump

  defective.

• Make sure the pump is plugged into the 

  correct power outlet, then turn the control dial 

  fully clockwise to the inflation position.

• 

Turn off and disconnect the power cord from the 

  power outlet, let the pump rest for more than 

  30 minutes before resume the use of the pump.

• 

Remove the internal air pump from the airbed 

  and keep the airbed in a safe place. Contact 

  Intex service center for an internal air pump 

  replacement.

Pump motor is

running but airbed

is not inflating or

deflating

• The inflation or

  deflation mode is

  not set yet.

 Turn the control dial fully clockwise until it 

  stops to inflate the airbed. Or turn the control 

  dial fully counterclockwise until it stops to 

  deflate the airbed.

After inflation air is

escaping through

the pump air 

passage or through 

the manual inflation 

port

• The pump air

  passage is not

  completely closed.

• The manual

  inflation port cap is

  not securely closed.

• Make sure the air passage is closed by 

  turning the control dial to the center closed / 

  pump off position.

• Push the cap firmly into the manual inflation 

  port.

TROUBlESHOOTINg gUIDE

Summary of Contents for Quickfill AP619D

Page 1: ...n must not be left unattended when using the airbed If a storage bag is included keep the storage bag away from babies and children The storage bag is not a toy When not in use fold the bag and put it away out of the reach of children Do not walk stand on or jump on or use the airbed as a trampoline Do not use on or near water This is not a raft Do not set up bed near stairs doors sharp edges or b...

Page 2: ...he inflated airbed when moving or changing location Maintenance instructions No air pump maintenance is required Pump is removable For cleaning use only clean cloth with mild soapy solution Do not use any chemicals In case of repairs use only common PVC repair glue and patches For flocked surfaces rub away the flocking material with an eraser first before applying the glue and or patch SERVICING O...

Page 3: ...ns Never disconnect the power cord from the electrical outlet while the pump is running Rotate control dial to the closed pump off position before disconnecting the power cord 5 If the airbed feels too firm release some air by simply turning the control dial gradually counterclockwise until air begins to escape from the air passage When the desired firmness is achieved turn the control dial back t...

Page 4: ...authorized agents or employees be liable for damages such as pin holes to the airbed caused by negligence ordinary wear and tear abuse and carelessness or external forces IMPORTANT NOTE DEFLATION 1 Plug in the AC power cord into an AC electrical outlet See Fig 2 2 Turn the control dial fully counterclockwise until it stops The pump is now deflating the airbed See Fig 5 3 When all the air is remove...

Page 5: ...P OR THE AIRBED COMPONENT If there is a need to replace either the internal air pump or the airbed portion detach the internal pump from the airbed as follows 1 While holding both lock tabs pressed inward see Figure 13 turn the round body of the pump the large outer rim not the control dial counterclockwise and pull the air pump body out of the holder frame 2 Depending on which part is being repla...

Page 6: ... ring back to the pump as to prevent dust lint from sticking onto the O ring again Also make sure the pump holder frame inner wall is free from dust hair or lint Remove the internal air pump and carefully replace the pump back making sure the internal airbed beam threads are away from the pump holder frame Remove the pump from the airbed make sure the O ring is not damaged and or twisted Realign t...

Reviews: