background image

(17PO)  AP619D/AP619DP-22 ELECTRIC PUMP  ENGLISH  4.875” X 7.25”  12/04/2021

English

17PO

READ AND SAVE THESE INSTRUCTIONS

Page 5

1. Open cord compartment cover and locate the

 

manual inflation port.

2.  Make sure the control dial of the internal electric

 

pump is still in the closed / pump off position.

3.  Remove the cap from the manual inflation port and

 

insert the nozzle of the pump into the port. Inflate the

 

airbed to desired firmness.

NOTE: 

Do not overinflate. The firmness should be

approximately the same as the level achieved with the

internal electric pump.
4.   Remove nozzle from manual inflation port and close

 

the cap and the cord compartment cover.

STORAgE INSTRUCTIONS

1.  Deflate the airbed following the “DEFLATION” instructions.

2.   Make sure the airbed is clean and dry.

3.   Lay the airbed flat with the sleeping surface facing upwards and follow the folding steps

 on 

Figs (8 - 12). Fold the airbed loosely and avoid sharp bends, corners and creases

  which can damage the airbed.

REPlACINg INTERNAl AIR PUMP OR THE AIRBED COMPONENT

If there is a need to replace either the internal air pump or the airbed portion, detach the 

internal pump from the airbed as follows:

1.  While holding both lock tabs pressed inward

 (see Figure 13)

, turn the round body of the

  pump (the large outer rim, not 

the control dial

) counterclockwise and pull the air pump   

  body out of the holder frame.

2.   Depending on which part is being replaced, keep the remaining component (either the

  airbed portion or the removed pump) in a safe place until the replacement part is

  received. Reattach the components when the new part is received: simply place

  the pump into the holder frame and turn clockwise untill the lock tabs click into place.

NOTE: 

Make sure the rubber seal on the pump housing as well as the inside wall of the

holder frame are clean and free from any lint, hair or dirt, to ensure a proper seal and avoid

air leaks.

NOTE: 

Do not remove internal air pump from the holder frame other than for servicing, as

this may introduce lint, hair or dirt into the seal area and cause air leaks. If air leak is

experienced, check that the seal is clean before replacing the pump or the airbed.

FIg (7)

FIg (8)

FIg (9)

FIg (10)

FIg (12)

FIg (11)

FIg (13)

1

2

1

Summary of Contents for Quickfill AP619D

Page 1: ...n must not be left unattended when using the airbed If a storage bag is included keep the storage bag away from babies and children The storage bag is not a toy When not in use fold the bag and put it away out of the reach of children Do not walk stand on or jump on or use the airbed as a trampoline Do not use on or near water This is not a raft Do not set up bed near stairs doors sharp edges or b...

Page 2: ...he inflated airbed when moving or changing location Maintenance instructions No air pump maintenance is required Pump is removable For cleaning use only clean cloth with mild soapy solution Do not use any chemicals In case of repairs use only common PVC repair glue and patches For flocked surfaces rub away the flocking material with an eraser first before applying the glue and or patch SERVICING O...

Page 3: ...ns Never disconnect the power cord from the electrical outlet while the pump is running Rotate control dial to the closed pump off position before disconnecting the power cord 5 If the airbed feels too firm release some air by simply turning the control dial gradually counterclockwise until air begins to escape from the air passage When the desired firmness is achieved turn the control dial back t...

Page 4: ...authorized agents or employees be liable for damages such as pin holes to the airbed caused by negligence ordinary wear and tear abuse and carelessness or external forces IMPORTANT NOTE DEFLATION 1 Plug in the AC power cord into an AC electrical outlet See Fig 2 2 Turn the control dial fully counterclockwise until it stops The pump is now deflating the airbed See Fig 5 3 When all the air is remove...

Page 5: ...P OR THE AIRBED COMPONENT If there is a need to replace either the internal air pump or the airbed portion detach the internal pump from the airbed as follows 1 While holding both lock tabs pressed inward see Figure 13 turn the round body of the pump the large outer rim not the control dial counterclockwise and pull the air pump body out of the holder frame 2 Depending on which part is being repla...

Page 6: ... ring back to the pump as to prevent dust lint from sticking onto the O ring again Also make sure the pump holder frame inner wall is free from dust hair or lint Remove the internal air pump and carefully replace the pump back making sure the internal airbed beam threads are away from the pump holder frame Remove the pump from the airbed make sure the O ring is not damaged and or twisted Realign t...