background image

263

PO

S  AVE THESE INSTRUCTIONS

(263PO)  SPA  ENGLISH  7.5” X 10.3”  PANTONE 295U  07/16/2014

English

Page 15

SPA WATER CHEMISTRY AND BALANCE (continued)

SPA Water Adjustment

How to adjust the spa water chemistry when the levels are off the range. 

CAUTION:

 Always follow the 

chemical manufacturer’s directions, and the health and hazard warnings.

Total Alkalinity (TA) Adjustment

Remove the spa cover to aerate the water and use the included test strips to check the chemistry level. 
Ensure the chlorine level in the water is between 2-4 ppm 

fi

 rst, as chlorine will affect the TA test result.

If the TA level (and not the pH) is higher than 120 ppm, to lower the TA level, you add muriatic acid (hydrochloric 
acid) or sodium bisulfate.
If the TA level is lower than 60 ppm, you add sodium bicarbonate.
For example, if the TA level is 180 ppm, the desired decrease is 60 ppm, from below chart, you need to add 
0.269 Lb (121 g) of sodium bisulfate or 0.101 qt (96 ml) of muriatic acid.

If the test strip color is between 180 ppm and 240 ppm, and close to 180 ppm, you can also add 0.269 Lb 
(121 g) of sodium bisulfate or 0.101 qt (96 ml) of muriatic acid.

If the reading is more than 240 ppm, you can add sodium bisulfate or muriatic acid to the water drop by drop 
until the test strip indicates a 240 ppm reading, then add 0.528 Lb (238 g) of sodium bisulfate or 0.202 qt 
(192 ml) of muriatic acid.

NOTE:

 After adjustment, retest the water after 24 hours and adjust again if necessary.

Desired level

60 ppm

80 ppm

100 ppm

120 ppm

140 ppm

Volume:

210 gal / 800 L

0.269 Lb

0.358 Lb

0.448 Lb

0.528 Lb

0.627 Lb

121 g

161 g

202 g

238 g

283 g

Lowering Total Alkalinity

Amount of Sodium Bisulfate to lower Total Alkalinity

Desired level

20 ppm

40 ppm

60 ppm

80 ppm

Volume:

210 gal / 800 L

0.059 Lb

0.118 Lb

0.178 Lb

0.237 Lb

27 g

53 g

80 g

107 g

Raising Total Alkalinity

Amount of Sodium Bicarbonate to raise Total Alkalinity

Desired level

60 ppm

80 ppm

100 ppm

120 ppm

140 ppm

Volume:

210 gal / 800 L

0.101 qt

0.135 qt

0.169 qt

0.202 qt

0.234 qt

96 mL

128 mL

160 mL

192 mL

223 mL

Amount of Muriatic Acid to lower Total Alkalinity

(Muriatic acid: 31.45%)

pH Adjustment

After the total alkalinity has been lowered to 120 ppm or raised to 80ppm and the pH is still high or low, you 
can adjust it using the following chart.

Summary of Contents for PureSpa SSP-H-10-1

Page 1: ... available at fine retailers or visit our website Due to a policy of continuous product improvement Intex reserves the right to change specifications and appearance which may result in updates to the instruction manual without notice For illustrative purposes only IMPORTANT DO NOT RETURN PRODUCT TO STORE To purchase parts and accessories or to obtain non technical assistance visit www intexcorp co...

Page 2: ...installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interferen...

Page 3: ... this purpose Risk of Electric Shock Do not permit any electric appliance such as a light telephone radio or television within 5 feet 1 5 m of a spa or hot tub Risk of Electric Shock Do not use the spa when it is raining thundering or lightning A wire connector is provided on this unit to connect a minimum 8 AWG 8 4 mm2 solid copper conductor between this unit and any metal equipment metal enclosu...

Page 4: ...rs plug adaptors or converter plugs to connect unit to electrical supply provide a properly located outlet Do not attempt to plug in or unplug this product while standing in water or when your hands are wet Do not leave the spa empty for extended period of time Do not expose the spa under direct sunshine Adequate drainage system must be provided around the spa to deal with overflow water Do not al...

Page 5: ...ge 5 PARTS Before assembling your product please take a few minutes to check the contents and become familiar with all the parts NOTE Drawings for illustration purpose only Actual product may vary Not to scale 8 10 11 18 17 19 9 21 23 22 2 7 3 4 5 15 16 20 25 12 13 14 24 26 27 6 29 30 28 1 A C B ...

Page 6: ...TER CARTRIDGE HOUSING LID 2 11797 15 INLET OUTLET PLUG 3 11739 16 SPA TUB 1 11879 17 SPA COVER 1 11878 18 SPA COVER INFLATABLE BLADDER PRE INSTALLED IN SPA COVER 1 11884 19 GROUND CLOTH 1 11933 20 CHEMICAL DISPENSER 1 11614 21 TEST STRIPS 1 11855 22 WRENCH 1 11742 23 PRESSURE GAUGE 1 11741 24 SUCTION FITTING 3 11695 25 INFLATION HOSE ADAPTOR 1 11829 26 MALE BUCKLE 8 11698 27 FEMALE BUCKLE 8 11799 ...

Page 7: ...ventilating system to prevent excess condensation moisture in the room Additional requirements for outdoor installation Spa owners may need to comply with local or states laws relating to childproof fencing safety barriers lighting and other safety requirements Contact your local building code enforcement office for further details Make sure the surface is level flat smooth and strong enough to su...

Page 8: ...sembly 1 Connect the control panel 3 cable plug into the receptacle on top of the spa control base and screw in the plug cover firmly by hand see drawing 1 2 Screw the control panel bolts 4 with the provided bolt wrench 6 to secure the control panel see drawing 2 3 Plug the spa control unit into a grounded electrical outlet Page 8 Inflation Inflate the Spa Tub Wall 1 Take out the ground cloth 19 a...

Page 9: ...dder 1 Open the inflation valve and insert the inflation hose 7 into the valve press to inflate until it is firm to the touch but not hard see drawing 8 2 Disconnect the inflation hose 7 from the air blower inflation outlet and the valve 3 Replace the control base inflation cap 5 back close and recess the inflation valve NOTE If there is a need to add some air to the spa tub wall or spa cover air ...

Page 10: ...them after usage for water filtration and cleaning 4 Before filling with water ensure the bottom drain valve caps are securely closed on the inside and outside 5 Fill the spa tub with freshwater to a level between MIN and MAX marked on the inside of the spa wall Do not over fill the spa Never move the spa tub with water inside and or with the control base attached to the spa as the spa or control ...

Page 11: ...nt Buttons Pressing the Temperature Increase or Decrease buttons will cause the LED to flash When flashing you can adjust to the desired temperature setting If you hold these buttons down the values will rapidly increase or decrease The new and desired temperature setting will remain on the LED display for 5 seconds to confirm the new value NOTE The default temperature is 68 F 20 C NOTE Temperatur...

Page 12: ... desired temperature Press the temperature increase button to set the desired water temperature If problem persists contact Intex Service center E95 Water temperature too high Turn off and unplug the control unit When the water has cooled down plug the GFCI RCD and restart all over again Turn the heater off then press the filter and bubble buttons to lower the water temperature If problem persists...

Page 13: ...sembly back onto the spa tub wall 2 Change the spa water every 2 3 months or it becomes cloudy and proper water chemistry does not clear it up See Spa Tub Drainage and Spa Tub Cleaning sections for details 3 Use spa chemicals to maintain proper water chemistry Spa damage resulting from misuse of chemicals and mismanagement of spa water is not covered by the warranty 4 All occupants must shower bef...

Page 14: ...ion cloudy water shorter filter heater runs eye skin irritation high chlorine demand Calcium Hardness CaCO3 refers to the amount of calcium and magnesium dissolved in the water Result if too low Difficulty balancing water corrosion of metal components eye skin irritation and water foaming Result if too high Scale formation cloudy water eye skin irritation difficulty balancing water and filter heat...

Page 15: ... you can also add 0 269 Lb 121 g of sodium bisulfate or 0 101 qt 96 ml of muriatic acid If the reading is more than 240 ppm you can add sodium bisulfate or muriatic acid to the water drop by drop until the test strip indicates a 240 ppm reading then add 0 528 Lb 238 g of sodium bisulfate or 0 202 qt 192 ml of muriatic acid NOTE After adjustment retest the water after 24 hours and adjust again if n...

Page 16: ... softener mix the spa hard water with the soft water according to the water volume ratio chart to lower the calcium hardness Initial level 1000 ppm 500 ppm 350 ppm 250 ppm Desired level 100 ppm Water Volume Ratio Vhard water Vsoft water 1 9 1 4 2 5 2 3 Lowering Calcium Hardness Using Soft Water Volume Total Alkalinity From To 6 8 7 2 210 gal 800 L 120 ppm 0 541 Lb 243 g 80 ppm 0 361 Lb 163 g Raisi...

Page 17: ...e a sponge and mild soap solution to wipe away any soil or stains on the inside of the spa wall Rinse thoroughly before refilling with clean water IMPORTANT Do not use steel wool hard brushes or abrasive cleaners Spa Tub Air Valve Fastening Check the spa tub air valve for leakage and tightness before use If air is leaking from the air valve use the provided wrench 22 to tighten the air valve as fo...

Page 18: ...ion is activated to avoid damage to the blower motor 4 Make sure all the spa components and accessories are thoroughly clean and dry before storage Air dry the spa tub in the sun for an hour before folding 5 Fold the spa tub loosely and avoid any sharp corners to prevent damage or leakage to the spa tub liner 6 Prepare additional new cartridges for next time use 7 Store the spa tub and accessories...

Page 19: ...ker feeding the spa electrical outlet only Contact a qualify electrician to correct the electrical fault Increase the temperature and attach the spa cover Clean or replace the filter cartridge in time If heater is in STANDBY mode press the flame button twice to heat up the water to the set temperature Contact Intex Service Center Turn off and unplug the spa Let it cool down and restart all over ag...

Page 20: ...hall be brought before an informal dispute settlement board and unless and until the provisions of these paragraphs are carried forth no civil action may be instituted The methods and procedures of this settlement board shall be subject to the rules and regulations set forth by the Federal Trade Commission F T C IMPLIED WARRANTIES ARE LIMITED TO THE TERMS OF THIS WARRANTY AND IN NO EVENT SHALL INT...

Reviews: