background image

250

PO

S  AVE THESE INSTRUCTIONS

(250PO)  SPA (JET + HARD WATER)  ENGLISH  7.5” X 10.3”  PANTONE 295U  01/10/2014

English

Page 12

OPERATION

 

  

On/Off Button: 

Once the unit is plugged in, use this button to active the control unit panel 

 

  

buttons. The light next to the button is green when activated. Press this button to turn off all 

 

  

currently activated functions.

 

  

Heat Button:

 

Use this button to activate the heating system. The pump will heat the spa water  

 

  

until the water temperature reaches the set temperature. After the current water temperature  

 

  

drops 2°F below the set temperature the heating system will restart. When the fl ame icon on the 

 

  

display is red, the heating system is activated. When the fl ame icon turns green, the water is at 

 

  

the set temperature and the heating system is at rest.

 

  

NOTE:

 If the heating system is activated the fi ltration system will automatically start.

 

  

NOTE: 

After turning off the heating system the fi ltration system will continue to operate 24 hours.

 

  

Celsius/Fahrenheit Toggle button: 

 

  

The temperature can be displayed in either Fahrenheit or Celsius. The system’s default is    

  

 

Fahrenheit.

 

  

Temperature Adjustment Buttons:

 Pressing the Temperature Increase or Decrease

 

  

buttons will cause the LED to fl ash. When fl ashing you can adjust to the desired temperature  

 

  

setting. If you hold these buttons down the values will rapidly increase or decrease. The new  

 

  

and desired temperature setting will remain on the LED display for 5 seconds to confi rm the new  

  

 

value.

 

  

NOTE:

 The default temperature is 68°F (20°C).

 

  

NOTE: 

Temperature adjustment ranges from 68°F (20°C) to 104°F (40°C).

 

  

NOTE: 

Recommend not to set the water temperature more than 100°F (38°C).

 

  

Water Filter Button:

 

  

This button turns the fi lter pump on and off.

  

 

The 

water 

fi lter icon on the display is green when activated.

 

  

NOTE:

 The built-in hard water treatment function works automatically in conjunction with the 

 

  

fi ltration system.

 

  

Water Jet Button:

 

Use this button to activate the jet massage system. After 1 hour of 

 

  

continues use, the jet massage system will automatically turn off. The water jet icon on the 

 

  

displays is green when activated. The angle of the water jet nozzles inside the spa tub wall can 

 

  

be adjusted manually.

 

  

WARNING:

 Do not run jet system when the cover is attached, air pressure may accumulate 

 

  

inside the spa and cause irreparable damage and bodily harm.

 

  

Jet Air Control Knob:

 Use this to add a mixture of air with the water jet pressure. Turn the 

 

  

knob clockwise to increase the mixture of airfl ow and counter-clockwise to decrease the mixture 

  

 

of 

airfl ow.

 

  

LED Display: 

Once plugged in the LED displays the current water temperature automatically.

IMPORTANT: 

The following conditions will lead to slow water heating:

•  The ambient temperature is lower than 50ºF (10ºC).
•  Outdoor wind speed is above 8-12 mph (3.5-5. 4m/s).
•  The jet function is activated when heating the spa water.
•  The spa is not properly covered with the spa cover when the water is heating.

A: Heat Button 
B: Celsius/Fahrenheit Toggle Button
C:  Temperature Increase Button 
D:  Temperature Decrease Button
E:  Water Filter Button
F:  Water Jet Button
G:  Jet Air Control Knob
H: LED Display
I: On/Off 

Button

F

E

D

C

B

A

H

I

G

SPA CONTROL UNIT PANEL

 

F

104

o

Summary of Contents for PureSpa SPJ-H-10

Page 1: ...d boats available at fine retailers or visit our website Due to a policy of continuous product improvement Intex reserves the right to change specifications and appearance which may result in updates to the instruction manual without notice For illustrative purposes only IMPORTANT DO NOT RETURN PRODUCT TO STORE To purchase parts and accessories or to obtain non technical assistance visit www intex...

Page 2: ... before running the spa or else alarm code E90 will display on the control panel To release the air Ensure the control panel is off press the button to turn it off Unscrew the drain valve cap on the control base side with a coin The air has been released once a steady stream of water is flowing out from the drain valve Wait for 15 seconds and screw the drain valve cap back Press the button to acti...

Page 3: ... shall be bonded to the equipment grounding bus with copper conductors not smaller than No 6 AWG Water temperature in excess of 38 C can be injurious to your health See Operation section WARNING CHILDREN SHOULD NOT USE SPAS OR HOT TUBS WITHOUT ADULT SUPERVISION DO NOT USE SPAS OR HOT TUBS UNLESS ALL SUCTION GUARDS ARE INSTALLED TO PREVENT BODY AND HAIR ENTRAPMENT PEOPLE USING MEDICATIONS AND OR HA...

Page 4: ...ded for this purpose Risk of Electric Shock Do not permit any electric appliance such as a light telephone radio or television within 5 feet 1 5 m of a spa or hot tub Risk of Electric Shock Do not use the spa when it is raining thundering or lightning A wire connector is provided on this unit to connect a minimum 6 AWG 13 3 mm2 solid copper conductor between this unit and any metal equipment metal...

Page 5: ...lug adaptors or converter plugs to connect unit to electrical supply provide a properly located outlet Do not attempt to plug in or unplug this product while standing in water or when your hands are wet Do not leave the spa empty for extended period of time Do not expose the spa under direct sunshine Adequate drainage system must be provided around the spa to deal with overflow water Do not allow ...

Page 6: ...lish Page 6 PARTS Before assembling your product please take a few minutes to check the contents and become familiar with all the parts NOTE Drawings for illustration purpose only Actual product may vary Not to scale 9 10 11 18 17 19 8 21 5 22 1 6 3 4 12 13 15 16 20 14 2 23 24 7 27 26 25 A B C A B C 28 ...

Page 7: ...R CARTRIDGE 2 11692 14 FILTER CARTRIDGE HOUSING LID 2 11797 15 INLET PLUG 1 11739 16 SPA TUB 1 11795 17 SPA COVER 1 11784 18 SPA COVER INFLATABLE BLADDER PRE INSTALLED IN SPA COVER 1 11689 19 GROUND CLOTH 1 11717 20 CHEMICAL DISPENSER 1 10883 21 TEST STRIPS 1 11855 22 WRENCH 1 11742 23 OUTLET PLUG 2 11782 24 CONTROL PANEL AIR HOSE CONNECTION O RING 1 11711 25 MALE BUCKLE 6 11850 26 FEMALE BUCKLE 6...

Page 8: ... spa installation The room shall be properly ventilated to allow moisture to escape Install a ventilating system to prevent excess condensation moisture in the room Additional requirements for outdoor installation Spa owners may need to comply with local or states laws relating to childproof fencing safety barriers lighting and other safety requirements Contact your local building code enforcement...

Page 9: ... Control Unit Assembly 1 Connect the control panel 3 cable plug and air hose plug into the respective receptacle on top of the spa control base and screw in the plug covers firmly by hand see drawing 1 IMPORTANT Ensure the control panel air hose connection o ring 24 is in place 2 Screw the control panel bolts 4 with the provided bolt wrench 6 to secure the control panel see drawing 2 3 Plug the sp...

Page 10: ... insert one end of the inflation hose 7 into the valve the other end to the electric air pump turn on the pump to inflate until the air bladder is firm to the touch but not hard see drawing 7 2 Disconnect the inflation hose 7 from the the valve and the electric air pump 3 Close and recess the inflation valve NOTE If there is a need to add some air to the spa tub wall or spa cover air bladder after...

Page 11: ...nd MAX marked on the inside of the spa wall Do not over fill the spa WARNING Never pour water with a temperature higher than 104 F 40 C into the spa directly It is recommended to fill the spa tub with lukewarm water for quick heating and energy saving 5 Place the spa cover and spa air bladder pre installed in spa cover over the spa tub and make sure the spa cover buckles are locked using the key p...

Page 12: ...t temperature is 68 F 20 C NOTE Temperature adjustment ranges from 68 F 20 C to 104 F 40 C NOTE Recommend not to set the water temperature more than 100 F 38 C Water Filter Button This button turns the filter pump on and off The water filter icon on the display is green when activated NOTE The built in hard water treatment function works automatically in conjunction with the filtration system Wate...

Page 13: ... the spa Turn off and unplug the control unit Plug the GFCI RCD and restart all over again Press the temperature increase button to set the desired water temperature If problem persists contact Intex Service Center E95 Water temperature too high Turn off and unplug the control unit When the water has cooled down plug the GFCI RCD and restart all over again Press the temperature decrease button to ...

Page 14: ...artridge housing assembly back onto the spa tub wall 2 Change the spa water every 2 3 months or it becomes cloudy and proper water chemistry does not clear it up See Spa Tub Drainage and Spa Tub Cleaning sections for details 3 Use spa chemicals to maintain proper water chemistry Spa damage resulting from misuse of chemicals and mismanagement of spa water is not covered by the warranty 4 All occupa...

Page 15: ... the spa tub wall clean and or replace the filter cartridge Use a sponge and mild soap solution to wipe away any soil or stains on the inside of the spa wall Rinse thoroughly before refilling with clean water IMPORTANT Do not use steel wool hard brushes or abrasive cleaners Spa Tub Air Valve Fastening Check the spa tub air valve for leakage and tightness before use If air is leaking from the air v...

Page 16: ...nal new cartridges for next time use 6 Store the spa tub and accessories in a dry temperature controlled between 32º 104 ºF 0º 40ºC storage location 7 The original packing can be used for storage STORAGE Spa Tub and Cover Air Bladder Repair Use the enclosed repair patch to repair any puncture Clean and dry the area to be repaired thoroughly Remove the patch backing paper and press patch firmly ove...

Page 17: ...ilter cartridge Filtration inlet and or outlet clogged Filter pump motor failed Clean or replace the filter cartridge in time Check and clean filtration inlet and outlet regularly Contact Intex Service Center WATER NOT CLEAN Cartridge assembly not properly attached Insufficient filtering time Dirty filter cartridge Improper water maintenance Filtration inlet and outlet clogged Ensure the cartridge...

Page 18: ...ranty shall be brought before an informal dispute settlement board and unless and until the provisions of these paragraphs are carried forth no civil action may be instituted The methods and procedures of this settlement board shall be subject to the rules and regulations set forth by the Federal Trade Commission F T C IMPLIED WARRANTIES ARE LIMITED TO THE TERMS OF THIS WARRANTY AND IN NO EVENT SH...

Reviews: