Heater Start Timer (HST) Button:
Use this button to select a future start time for the
heating system. Press this button and then press
or
to set the number of hours by
which you wish to delay the start of the heating system, from 000 to 120 hours. The icon will
fl
ash red for a few seconds and then stays red. The information shown on the LED display
alternates between the remaining hours before heater start and the water temperature. Once
the countdown timer reaches 000, the heating system will start operating. To deactivate the
function at any time, simply set the HST time back to 000. To readjust the preset hours, press
the HST button twice and adjust the hours with
and
buttons.
Example 1:
It is 9:00pm Monday evening and you would like the spa to be hot on Friday
evening. Allowing for 24 hours for the spa to heat up (4 persons model about 3-4.5ºF (1.5-2.5ºC)
per hour) the heater should be set to start on Thursday evening. With the Spa turned on,
fi
rst
press the Heat button and set your desired temperature. Press the HST button and then
or
until 072 hours is shown. The heater will start after 72 hours has passed (Thursday at
9:00pm) and will run until the desired temperature is attained. The heater will then cycle on
and off to maintain the set temperature until turned off. To turn off the heater, press the
fl
ame
button.
Heater Duration Timer (HDT) Button:
Use this button to select the desired length of time the
heating system should operate. Press this button and then press
or
to set the number
of hours you wish the heater to operate before it automatically turns off, from 000 to 048 hours.
The icon will
fl
ash red for a few seconds and then stays red. The heating system will operate
for the amount of preset hours only. The timer takes priority over temperature, so the heater
will shut off when HDT time runs out regardless if the preset spa water temperature is reached
or not. During the HDT function, the information shown on the LED display alternates between
the remaining heater operating hours and the water temperature. Repeat previous steps to
reprogram this function. To deactivate the function at any time, simply set the HDT time back
to 000. To readjust the preset hours, press the HDT button twice and adjust the hours with
and
buttons.
Example 2:
Using the same scenario as example 1 above but rather than manually turning
the heater off when you are
fi
nished, you would like the heater to turn off automatically on
Saturday evening at 9:00pm. After going through the steps in example 1, press the HDT button
and then the
or
button to select 048 hours. The heater will then run from Thursday at
9:00pm to Saturday at 9:00pm.
NOTE:
If HST and HDT timers are both set, the LED display will
fi
rst alternate between
remaining time before the heater start and the water temperature, until HST timer runs out and
the heater activates. Then the LED display alternates between remaining HDT time and water
temperature until the HDT timer runs out as well.
SPA CONTROL PANEL
I: Heater Start Timer (HST) Button
J: Heater Duration Timer (HDT) Button
OPERATION (continued)
I