MAINTENANCE (continued)

The Test Strips can test the “Free Chlorine”, “pH”, “Calcium Hardness” and “Total Alkalinity” 

levels at the same time. We recommend that you test the water chemistry weekly, and maintain 

the chlorine concentration at 0.5-3 ppm.

Directions and Use

1.

  Dip the entire strip into the water and remove immediately.

2.

  Hold the strip level for 15 seconds. Do not shake excess water from the strip.

3.

  Now compare the strip pad to the color chart on the packaging label. If necessary, adjust the 

 

chemical level in the pool water. It is very important, to use the proper technique when testing 

 

the water’s chemical level. Read and follow the written strip instructions carefully.

INTEX

®

 TEST STRIPS (PACKED WITH THE PRODUCT)

LONG TERM STORAGE

1.

  Disconnect the power cord from the electrical outlet.

2.

  After the pool is completely empty, disconnect the Ozone & Saltwater System from the hoses 

 

by reversing the installation instructions. 

3.

  Air-dry the unit before you store it. This might be a good time to visually inspect and clean the 

 electrolytic 

cell.

4.

  Store the unit and accessories in a dry place. The temperature should be controlled, between 

 

32 degrees Fahrenheit (0 degrees Celsius) and 97 degrees Fahrenheit (36 degrees Celsius).

5.

  The original package can be used for storage.

Summary of Contents for L ZS6220

Page 1: ...7 2017 Intex Marketing Ltd Intex Development Co Ltd Intex Trading Ltd Intex Recreation Corp All rights reserved Tous droits r serv s Todos los derechos reservados Alle Rechte vorbehalten Printed in Ch...

Page 2: ...lt Table 9 Intex Pools Cyanuric Acid Table 10 Intex Pools Operating Time Table 11 Non Intex Pools Salt Table 12 Non Intex Pools Cyanuric Acid Table 12 Non Intex Pools Operating Time Table 12 Operating...

Page 3: ...installed Do not bury the electrical cord Locate the cord where it will not be damaged by lawn mowers hedge trimmers and other equipment If the supply cord is damaged it must be replaced by the manufa...

Page 4: ...t may vary Not to scale When ordering parts be sure to quote the model number and part numbers 4 1 3 9 8 7 6 5 2 10 2 12 11 REF NO DESCRIPTION QTY SPARE PART NO 1 ADAPTOR A WITH THREADED COLLAR OPTION...

Page 5: ...rts destroying bacteria and algae It also oxidizes all other organic materials Ozone is made by drawing air through Corona Discharge CD cells that break down oxygen molecules which then recombine into...

Page 6: ...filter pump 1500 4000 gph 5680 15140 lph to drive the water and function properly The Ozone Saltwater System must be installed as the last piece of pool equipment in the water return line to the pool...

Page 7: ...pump outlet connection with a large hose clamp Tighten securely Connecting the system to other types of pool After you have connected the Ozone Saltwater System to the pump connect it to the pool This...

Page 8: ...ue only to pool water being physically removed from the pool Salt is not lost due to evaporation Adding Salt 1 Switch the filter pump on to start the water circulation 2 Keep the Ozone Saltwater Syste...

Page 9: ...549cm x 132cm 20 x 48 610cm x 122cm 22 x 52 671cm x 132cm 24 x 52 732cm x 132cm 26 x 52 792cm x 132cm 15 8 x 49 478cm x 124cm 16 8 x 49 508cm x 124cm 18 8 x 53 569cm x 135cm 18 x 10 x 42 549cm x 305c...

Page 10: ...x 122cm 7947 30079 2 0 0 9 22 x 52 671cm x 132cm 10472 39637 2 6 1 2 24 x 52 732cm x 132cm 12481 47241 3 1 1 4 26 x 52 792cm x 132cm 14667 55515 3 7 1 7 GRAPHITE GRAY PANEL Pool SET 15 8 x 49 478cm x...

Page 11: ...18 x 52 549cm x 132cm 20 x 48 610cm x 122cm 22 x 52 671cm x 132cm 24 x 52 732cm x 132cm 26 x 52 792cm x 132cm 15 8 x 49 478cm x 124cm 16 8 x 49 508cm x 124cm 18 8 x 53 569cm x 135cm 18 x 10 x 42 549cm...

Page 12: ...artup Kgs Salt Needed when Low Salt Detected Lbs Salt Needed when Low Salt Detected Kgs Water Capacity Gals x 0 025 Water Capacity Liters x 0 003 Water Capacity Gals x 0 0067 Water Capacity Liters x 0...

Page 13: ...timer will now activate your Ozone Saltwater System at the same time each day for the number of hours you have set NOTE The Ozone Saltwater System will not operate if the filter pump is not operating...

Page 14: ...LEEP indicator on the control panel lights up and the LED display flashes 93 The system is now in Stand By mode After a while it shuts down and sets itself in a Power Saving mode The system will autom...

Page 15: ...aining 08 Operating Hours 8 hours remaining 09 Operating Hours 9 hours remaining 10 Operating Hours 10 hours remaining 11 Operating Hours 11 hours remaining 12 Maximum Operating Hours 12 hours remaini...

Page 16: ...your local authorities to determine if there is a regulation in your area regarding above the ground swimming pool filter pumps If yes then the product can be mounted to a platform using the two hole...

Page 17: ...its position Do not overtighten Electrolytic Cell Cleaning The electrolytic cell has a self cleaning function incorporated into the electronic control s programming In most cases this self cleaning a...

Page 18: ...the flow sensor from the electrolytic cell 9 housing 5 Pour kitchen grade vinegar into the electrolytic cell 9 to immerse the titanium electrodes Soak for 1 hour 6 Open one side of the cell cover 11...

Page 19: ...label If necessary adjust the chemical level in the pool water It is very important to use the proper technique when testing the water s chemical level Read and follow the written strip instructions c...

Page 20: ...ffect on pH Result if too high Scale formation cloudy water eye skin irritation poor chlorine efficiency Calcium Hardness Refers to the amount of calcium and magnesium dissolved in the water Result if...

Page 21: ...manual Check the direction of the inlet and the outlet hose Reverse the hoses if necessary See Set Up Instructions Clean the flow sensor paying special attention to the hinge See Maintenance Plug the...

Page 22: ...propriate stabilizer See Cyanuric Acid table Use a pool cover when the pool is not in use and or when the unit is operating Increase the daily Ozone Saltwater System operating time See Operating Instr...

Page 23: ...duct package and package insert warnings and instructions Remember however that product warnings instructions and safety guidelines cover some common risks of water recreation but do not cover all ris...

Page 24: ...er will inspect the item and determine the validity of the claim If the item is covered by the provisions of the warranty the item will be repaired or replaced with the same or comparable item at Inte...

Reviews: