Boost cycle
•
If the test result is below 0.1ppm, press and hold “BOOST” button for 5
seconds until the indicator lights up and the LED display shows “80”. This
indicates that the saltwater system has started copper ion and more
chlorine sanitizer production. You can press and hold the “BOOST” button
for another 5 seconds until the indicator is off, which will cancel the Boost
cycle.
Note:
Once the system has started copper ion and more chlorine sanitizer
production, the boost button can’t be re-set until the power switch is off.
•
The boost operating hours is 8 times the amount of time programmed into the system, i.e. if your
saltwater system operating time is 2 hours, the boost procedure will run 8 x 2 = 16 hours.
After
boost procedure has been completed, the system will automatically switch to the normal
working mode.
•
Once the boost is operating, check whether the filter pump operating hours have been set
properly. For example, the boost operating time is 8 hours, the filter pump should be set to
run for 8 hours at least. Increase the filter pump operating time if necessary.
Note:
If an Intex filter pump is attached to the system, set the pump switch to on “I” position.
•
After a heavy rain or if the pool is dirty, press the “BOOST” button to shock the pool again.
8
.
Test pool water regularly:
Once the copper level appears to be balanced, test the pool water every week to maintain
the proper sanitizer level.
It’s very important that the free chlorine is between 0.5-3.0 ppm and copper ion concentration
is between 0.1~0.2 ppm. When the copper level is below 0.1 ppm, repeat step 7.
NOTE:
A High copper ion concentration may cause blonde hair to exhibit a green hair. To
prevent this, wear a swimming cap during swimming, and wash hair with special shampoo
after using the pool. See “Troubleshooting Guide”.
9. Stand-by/power saving mode:
•
When the cycle ends, the green “SLEEP” indicator on the control panel
lights up and the LED display flashes “93”. The system is now in Stand-By
mode. After a while, it shuts down and sets itself in a Power Saving mode.
The system will automatically turn itself back on in 24 hours, starting its
daily cycle of chlorine production.
•
The “SLEEP” indicator stays on, while the system is in the Power Saving
mode. The LED display however, goes blank after 5 minutes. Press any
button ( or ) to view the last LED code.