INTEX POOLS CYANURIC ACID TABLE

Cyanuric acid is a chemical that reduces the loss of chlorine in water due to ultraviolet rays. To 

maintain the pool water clear and clean, and to maximize the performance of the device, add 

cyanuric acid to the pool. We recommend that the cyanuric acid level be maintained at 

approximately 1% of the salt, i.e. 100 Lbs (45 Kgs) salt x1% = 1 Lbs (0.45 Kgs) cyanuric acid.

If the pool water is dirty, filthy or grimy, DO NOT add chlorine stabilizer (cyanuric acid) as this 

will slowdown the sanitation time of the device. Under this condition you must BOOST your 

pool water, refer to BOOST cycle steps. Once the pool water has been restored to clear and 

clean conditions you may add cyanuric acid.

Pool Size

Water Capacity (Calculated at 

90% for Frame Pool and 80% 

for Easy Set & Oval Pool)

Cyanuric Acid Needed for 

Startup

0.03g/L (30ppm)

(Gals)

(Liters)

(Lbs)

(Kgs)

 INTEX ABOVE GROUND POOLS (AGP’s)

EASY SET® 

POOL

15’ x 33” (457cm x 84cm)

2587 

9792 

0.6 

0.3 

15’ x 36” (457cm x 91cm)

2822 

10681 

0.7 

0.3 

15’ x 42” (457cm x 107cm)

3284 

12430 

0.8 

0.4 

15’ x 48” (457cm x 122cm)

3736 

14141 

0.9 

0.4 

16’ x 42” (488cm x 107cm)

3754 

14209 

0.9 

0.4 

16’ x 48” (488cm x 122cm)

4273 

16173 

1.1 

0.5 

16’ x 52” (488cm x 132cm)

4614 

17464 

1.2 

0.5 

18’ x 42” (549cm x 107cm)

4786 

18115 

1.2 

0.5 

18’ x 48” (549cm x 122cm)

5455 

20647 

1.4 

0.6 

CIRCULAR

METAL

  

FRAME POOL

15’ x 36” (457cm x 91cm)

3282 

12422 

0.8 

0.4 

15’ x 42” (457cm x 107cm)

3861 

14614 

1.0 

0.4 

15’ x 48” (457cm x 122cm)

4440 

16805 

1.1 

0.5 

16’ x 48” (488cm x 122cm)

5061 

19156 

1.3 

0.6 

18’ x 48” (549cm x 122cm)

6423 

24311 

1.6 

0.7 

21’ x 52” (640cm x 132cm)

9533 

36082 

2.4 

1.1 

24’ x 52” (732cm x 132cm)

12481 

47241 

3.1 

1.4 

ULTRA 

FRAME®

POOL

16’ x 48” (488cm x 122cm)

5061 

19156 

1.3 

0.6 

18’ x 48” (549cm x 122cm)

6423 

24311 

1.6 

0.7 

18’ x 52” (549cm x 132cm)

6981 

26423 

1.7 

0.8 

20’ x 48” (610cm x 122cm)

7947 

30079 

2.0 

0.9 

22’ x 52” (671cm x 132cm)

10472 

39637 

2.6 

1.2 

24’ x 52” (732cm x 132cm)

12481 

47241 

3.1 

1.4 

26’ x 52” (792cm x 132cm)

14667 

55515 

3.7 

1.7 

SEQUOIA 

SPIRIT® 

POOL SET

15’8” x 49” (478cm x 124cm)

4440 

16805 

1.1 

0.5 

16’8” x 49” (508cm x 124cm)

5061 

19156 

1.3 

0.6 

18’8” x 53” (569cm x 135cm)

6981 

26423 

1.7 

0.8 

OVAL FRAME

POOL

18’ x 10’ x 42” (549cm x 305cm x 107cm)

2885 

10920 

0.7 

0.3 

20’ x 12’ x 48” (610cm x 366cm x 122cm)

4393 

16628 

1.1 

0.5 

RECT. ULTRA

FRAME POOL

15’ x 9’ x 48” (457cm x 274cm x 122cm)

3484 

13187 

0.9 

0.4 

18’ x 9’ x 52” (549cm x 274cm x 132cm)

4545 

17203 

1.1 

0.5 

20 x 10’ x 52” (610cm x 305cm x 132cm)

5835 

22085 

1.5 

0.7 

24’ x 12’ x 52” (732cm x 366cm x 132cm)

8403 

31805 

2.1 

1.0 

32’ x 16’ x 52” (975cm x 488cm x 132cm)

14364 

54368 

3.6 

1.6 

Summary of Contents for Krystal Clear CS8220

Page 1: ...1407 2013 Intex Marketing Ltd Intex Development Co Ltd Intex Trading Ltd Intex Recreation Corp All rights reserved Tous droits réservés Todos los derechos reservados Alle Rechte vorbehalten Printed in China Imprimé en Chine Impreso en China Gedruckt in China Trademarks used in some countries of the world under license from Marques utilisées dans certains pays sous licence de Marcas registradas uti...

Page 2: ...ex Pools Salt Table 12 Intex Pools Cyanuric Acid Table 13 Intex Pools Operating Time Table 14 Non Intex Pools Salt Table 15 Non Intex Pools Cyanuric Acid Table 15 Non Intex Pools Operating Time Table 15 Operating Instructions 16 17 LED Code Chart 18 Stationary Mounting 19 Maintenance 20 22 Long Term Storage 22 Pool Maintenance and Chemical Definitions 23 Troubleshooting Guide 24 25 General Aquatic...

Page 3: ...ate the cord where it will not be damaged by lawn mowers hedge trimmers and other equipment The supply cord cannot be replaced If the cord is damaged the appliance should be scrapped To reduce the risk of electric shock do not use extension cords timers plug adaptors or converter plugs to connect unit to electric supply provide a properly located outlet Do not attempt to plug in or unplug this pro...

Page 4: ...MON PARTS PARTS FOR CONNECTION TO FILTER PUMPS WITH 1 1 4 32MM HOSE SIZE 1 ADAPTOR A WITH THREADED COLLAR 1 10849 2 O RING A 1 10712 3 SCREW 2 11519 4 ELECTROLYTIC CELL O RING A INCLUDED 1 11433 5 COPPER ELECTRODE 1 11234 6 TITANIUM ELECTRODE 1 11374 7 FLOW SENSOR 1 11460 8 CONNECTOR HOSE WITH THREADED FITTINGS 1 10720 9 THREADED ADAPTOR B 1 10722 10 CELL COVER 2 11131 11 ELECTROLYTIC CELL NUT 1 1...

Page 5: ...rine dissolves in the water and instantly starts destroying bacteria and algae It also oxidizes all other organic materials Low voltage direct current is applied to the copper electrode and copper ions are generated and dissolved instantly in the water Copper is an effective algaecide which will prevent algae from growing in the pool HOW THE CHLORINE IS GENERATED Wattage 125W Ideal Salt Level 3000...

Page 6: ...h 1 1 4 32mm connections hoses The saltwater system features 1 1 2 38mm connections It is accordingly supplied with adaptors A 1 and B 9 for connecting to the small 1 1 4 32mm diameter connections hoses Install as follows Drawing 1 IMPORTANT The Saltwater System requires a separate filter pump 700 4000 gph 2650 15140 lph to drive the water and function properly The Saltwater System must be install...

Page 7: ...ter pool system 2 Connect the adaptor A 1 to the electrolytic cell 4 outlet as shown in Drawing 1 Tighten securely 3 Disconnect the water return hose from the filter pump connection and connect it to the adaptor A 1 on the Saltwater System with a hose clamp see Drawing 1 4 Connect adaptor B 9 to the connector hose 8 Tighten securely see Drawing 1 5 Connect adaptor B 9 to filter pump outlet lower c...

Page 8: ...wing 2 1 Go directly to step 2 if your pool is empty If your above ground pool is filled with water close the plunger valves before installing the Saltwater System 2 Disconnect the water return hose from the filter pump connection and connect it to the Saltwater System outlet 3 Connect the connector hose 8 to the filter pump outlet connection 4 Open the plunger valves to allow the water to flow 8 ...

Page 9: ...read on the connection Connection to 1 1 4 32mm hose 1 Connect one end of adaptor B 9 to the connector hose 8 Tighten securely 2 Now connect the other end of adaptor B 9 to the filter pump outlet Tighten securely Connection to 1 1 2 38mm hose with clamp 1 Connect the connector hose 8 to the filter pump outlet connection with a large hose clamp Tighten securely SETUP INSTRUCTIONS continued ID 1 1 4...

Page 10: ...onnectors 1 Connect the adaptor A 1 to the electrolytic cell 4 outlet Tighten securely 2 The adapter A 1 is now fitted to the Saltwater System The following step is to connect the water return hose to the adaptor A 1 with a hose clamp Connection to 1 1 2 38mm connectors without thread 1 Connect the adaptor A 1 to the electrolytic cell 4 outlet Tighten securely 2 With the adaptor A 1 fixed to the S...

Page 11: ...e only to pool water being physically removed from the pool Salt is not lost due to evaporation Adding Salt 1 Switch the filter pump on to start the water circulation 2 Keep the Saltwater System turned off 3 Determine the amount of salt to be added see Salt Table 4 Evenly spread the proper amount of salt around the inside perimeter of the pool 5 Avoid clogging the filter Do not add salt through th...

Page 12: ...x 132cm 20 x 48 610cm x 122cm 22 x 52 671cm x 132cm 24 x 52 732cm x 132cm 26 x 52 792cm x 132cm 15 8 x 49 478cm x 124cm 16 8 x 49 508cm x 124cm 18 8 x 53 569cm x 135cm 18 x 10 x 42 549cm x 305cm x 107cm 20 x 12 x 48 610cm x 366cm x 122cm 15 x 9 x 48 457cm x 274cm x 122cm 18 x 9 x 52 549cm x 274cm x 132cm 20 x 10 x 52 610cm x 305cm x 132cm 24 x 12 x 52 732cm x 366cm x 132cm 32 x 16 x 52 975cm x 488...

Page 13: ... 16 x 42 488cm x 107cm 3754 14209 0 9 0 4 16 x 48 488cm x 122cm 4273 16173 1 1 0 5 16 x 52 488cm x 132cm 4614 17464 1 2 0 5 18 x 42 549cm x 107cm 4786 18115 1 2 0 5 18 x 48 549cm x 122cm 5455 20647 1 4 0 6 CIRCULAR METAL FRAME POOL 15 x 36 457cm x 91cm 3282 12422 0 8 0 4 15 x 42 457cm x 107cm 3861 14614 1 0 0 4 15 x 48 457cm x 122cm 4440 16805 1 1 0 5 16 x 48 488cm x 122cm 5061 19156 1 3 0 6 18 x ...

Page 14: ... 52 549cm x 132cm 20 x 48 610cm x 122cm 22 x 52 671cm x 132cm 24 x 52 732cm x 132cm 26 x 52 792cm x 132cm 15 8 x 49 478cm x 124cm 16 8 x 49 508cm x 124cm 18 8 x 53 569cm x 135cm 18 x 10 x 42 549cm x 305cm x 107cm 20 x 12 x 48 610cm x 366cm x 122cm 15 x 9 x 48 457cm x 274cm x 122cm 18 x 9 x 52 549cm x 274cm x 132cm 20 x 10 x 52 610cm x 305cm x 132cm 24 x 12 x 52 732cm x 366cm x 132cm 32 x 16 x 52 9...

Page 15: ...for Startup Lbs Salt Needed for Startup Kgs Salt Needed when Low Salt Detected Lbs Salt Needed when Low Salt Detected Kgs Water Capacity Gals x 0 025 Water Capacity Liters x 0 003 Water Capacity Gals x 0 0067 Water Capacity Liters x 0 0008 CYANURIC ACID TABLE FOR COMMON NON INTEX POOLS Water Capacity Cyanuric Acid Needed for Startup 0 03g L 30ppm Gals Liters Lbs Kgs 2000 4000 6000 8000 10000 12000...

Page 16: ...ate if the filter pump is not operating Make sure to program your filter pump or start it manually for operation beginning 5 minutes before the saltwater system and finishing 15 minutes after the saltwater system 4 Lock keypad controls With the desired hour value showing press button until you hear a beep A green WORKING indicator on the control panel will light up within a few seconds to indicate...

Page 17: ...p should be set to run for 8 hours at least Increase the filter pump operating time if necessary Note If an Intex filter pump is attached to the system set the pump switch to on I position After a heavy rain or if the pool is dirty press the BOOST button to shock the pool again 8 Test pool water regularly Once the copper level appears to be balanced test the pool water every week to maintain the p...

Page 18: ... remaining 08 Operating Hours 8 hours remaining 09 Operating Hours 9 hours remaining 10 Operating Hours 10 hours remaining 11 Operating Hours 11 hours remaining 12 Maximum Operating Hours 12 hours remaining 90 Alarm Code Low Pump Flow No Flow 91 Alarm Code Low Salt Level 92 Alarm Code High Salt Level 93 Stand By Mode Operating Process finished BLANK No Power or Power Saving Mode waiting to start n...

Page 19: ... with your local authorities to determine if there is a regulation in your area regarding above the ground swimming pool filter pumps If yes then the product can be mounted to a platform using the two holes located in the base See drawing below The product can be mounted on a cement base or onto a wooden platform to prevent accidental tipping Total assembly must exceed 18kg 1 The mounting holes ar...

Page 20: ...nsor to the connection ridge in the conduit Now turn the collar in a clockwise motion tightening the sensor back into its position Do not overtighten Electrolytic Cell Cleaning The electrolytic cell 4 has a self cleaning function incorporated into the electronic control s programming In most cases this self cleaning action will keep the cell working at optimum efficiency If the pool water is hard ...

Page 21: ...of the copper electrode 5 and remove it from the electrolytic cell 4 Lift up the copper electrode 5 Pour kitchen grade vinegar into the cell to immerse the titanium plates Then put the copper electrode back in the cell soak them for about one hour until no colored areas remain 6 Open one side of the cell cover 10 drain and properly dispose of the vinegar Connect the hose which goes from the pool t...

Page 22: ...fully 1 Disconnect the power cord from the electrical outlet 2 After the pool is completely empty disconnect the Saltwater System from the hoses by reversing the installation instructions 3 Air dry the unit before you store it This might be a good time to visually inspect and clean the electrolytic cell 4 Store the unit and accessories in a dry place The temperature should be controlled between 32...

Page 23: ...pm 20 40 ppm 50 ppm Free Chlorine Is the chlorine residual present in pool water Combined Chlorine Is formed by the reaction of free chlorine with ammonia wastes Result if too high Sharp chlorinous odor eye irritation pH A value that indicates how acidic or basic a solution is Result if too low Corroded metals eye skin irritation destruction of total alkalinity Result if too high Scale formation c...

Page 24: ...he test strips If the pool is clean and clear add stabilizer to the water and then test the water with the device running Increase operating time per day See Operating Instructions Use PH decrease chemical to adjust contact your local pool chemical store Increase the operating time per day See Operating Instructions Remove the cell for inspection clean it if necessary See Maintenance Contact Intex...

Page 25: ... they are open Clear your filter cartridge and cell from debris and dirt See Maintenance Release all trapped air in the circulation line See the filter pump manual Check the direction of the inlet and the outlet hose Reverse the hoses if necessary See Set Up Instructions Clean the flow sensor paying special attention to the hinge See Maintenance Plug the flow sensor firmly into the flow sensor rec...

Page 26: ...dangers For additional safeguards also familiarize yourself with the following general guidelines as well as guidelines provided by nationally recognized Safety Organizations Demand constant supervision A competent adult should be appointed as a lifeguard or water watcher especially when children are in and around the pool Learn to swim Take the time to learn CPR and first aid Instruct anyone who ...

Page 27: ...e please contact the appropriate Intex Service Center listed in the separate Authorized Service Centers sheet The Service Center will determine the validity of the claim IMPLIED WARRANTIES ARE LIMITED TO THE TERMS OF THIS WARRANTY AND IN NO EVENT SHALL INTEX THEIR AUTHORIZED AGENTS OR EMPLOYEES BE LIABLE TO THE BUYER OR ANY OTHER PARTY FOR DIRECT OR CONSEQUENTIAL DAMAGES OR LIABILITIES Some countr...

Reviews: