241A
SAVE THESE INSTRUCTIONS
(241IO) SALTWATER SYSTEM & SAND FILTER PUMP (14” & 16”) ENGLISH 7.5” X 10.3” PANTONE 295U 08/09/2013
English
Page 24
SALT TABLE FOR COMMON NON-INTEX POOLS
SALT CALCULATION FORMULA FOR ALL POOLS
Salt Needed for Startup
(Lbs)
Salt Needed for Startup
(Kgs)
Salt Needed when
Low Salt Detected (Lbs)
Salt Needed when
Low Salt Detected (Kgs)
Water Capacity (Gals) x 0.025
Water Capacity (Liters) x 0.003
Water Capacity (Gals) x 0.0067
Water Capacity (Liters) x 0.0008
Water Capacity
Salt Needed for Startup
Salt Needed when Low Salt
Detected (CODE “91”)
(Gals)
(Liters)
CS20220/CS20230 CS15220/CS15230 CS20220/CS20230 CS15220/CS15230
(Lbs)
(Kgs)
(Lbs)
(Kgs)
(Lbs)
(Kgs)
(Lbs)
(Kgs)
2000
7500
50
20
50
20
10
5
10
5
4000
15000
100
45
100
45
25
10
25
10
6000
22500
150
65
150
65
40
20
40
20
8000
30000
200
90
-
-
55
25
-
-
8500
32000
-
-
210
95
-
-
55
25
10000
37500
250
110
-
-
70
30
-
-
12000
45500
300
135
-
-
80
35
-
-
14000
53000
350
160
-
-
95
45
-
-
OPERATING TIME TABLE FOR COMMON NON-INTEX POOLS
Water Capacity
Operating Time (hours)
at different ambient/air temperatures
(Gals)
(Liters)
CS20220/CS20230
CS15220/CS15230
10 - 19°C
(50 - 66°F)
20 - 28 °C
(68 - 82 °F)
29 - 36 °C
(84 - 97 °F)
10 - 19°C
(50 - 66°F)
20 - 28 °C
(68 - 82 °F)
29 - 36 °C
(84 - 97 °F)
2000
7500
1 1 1 1
2
3
4000
15000
2 2 3 3
3
4
6000
22500
3 3 4 4
5
6
8000
30000
1 4
5 -
-
-
8500
32000
-
-
-
6
7
8
10000
37500
5 5 6
-
-
-
12000
45500
6
6
7
-
-
-
14000
53000
7
7
8
-
-
-
CYANURIC ACID TABLE FOR COMMON NON-INTEX POOLS
Water Capacity
Cyanuric Acid Needed for Startup 0.03g/L (30ppm)
(Gals)
(Liters)
CS20220/CS20230
CS15220/CS15230
(Lbs)
(Kgs)
(Lbs)
(Kgs)
2000
7500
0.5
0.23
0.5
0.23
4000
15000
1.0
0.45
1.0
0.45
6000
22500
1.5
0.68
1.5
0.68
8000
30000
2.0
0.90
-
-
8500
32000
-
-
2.13
0.96
10000
37500
2.5
1.13
-
-
12000
45500
3.0
1.37
-
-
14000
53000
3.5
1.59
-
-