ALARMS
Automatic Alarms
No sanitizer production will occur if “Low Water Flow”, “Low Saltwater Level in the saltwater tank”
or “High Salt Concentration” conditions are detected. If any of these conditions occur then the
saltwater system will sound an alarm that indicates sanitizer production has stopped. A buzzer will
sound for an hour and the right side red LED on the control panel will light up. The saltwater
system will go to power saving mode. Turn off the power of the unit and follow the solutions below
in order to solve the problem. Turn on the unit again by following the “Operating Instructions”.
CHECK
CAUSE
REMEDY
RIGHT LED
LIGHT
BUZZER
C
1. Circulation line
blocked.
•
Ensure the plunger valves are
opened (if any).
•
Ensure your filter cartridge is clear
from debris and dirt. See Filter
Pump Manual.
•
Release all trapped air in the
circulation line. See Filter Pump
Manual.
2. Incorrect inlet and
outlet hose direction.
•
Check for the direction of water
inlet and water outlet hose. Reverse
the hoses if necessary. See “Set Up
Instructions”.
1. Low Water Flow or
No Flow
3. Flow sensor
failure.
•
Contact Intex Service Center for
replacement.
Yes
Yes
2. Low Saltwater
Level or No Saltwater
1. Saltwater ran out
in the saltwater tank.
•
Drain out all the water in the
saltwater tank. Refill water and add
salt in the saltwater tank. See "How
to Add or Remove Salt".
Yes
Yes
1. Added too much
salt or not filled with
enough water.
•
Drain out all the water in the
saltwater tank. Refill water and add
salt in the saltwater tank. See "How
to Add or Remove Salt".
3. High Salt
Concentration
2. Possible motor or
electrolytic cell failure
•
Contact Intex Service Center.
Replace the cell if needed.
Yes
Yes