Safety

 

instructions

 

 

 

 

 

The

 

live

 

components

 

have

 

to

 

be

 

installed

 

only

 

by

 

a

 

qualified

 

electrician.

 

In

 

case

 

of

 

failure

 

of

 

the

 

electronic

 

device,

 

the

 

product

 

has

 

to

 

be

 

repaired

 

by

 

a

 

qualified

 

electrician

 

before

 

being

 

operated

 

again.

 

There

 

is

 

a

 

risk

 

of

 

electric

 

shock!

  

The

 

outlet

 

circuit

 

used

 

for

 

the

 

device

 

has

 

to

 

be

 

secured

 

through

 

a

 

circuit

 

breaker

 

protected

 

(16

 

A

 

in

 

several

 

countries).

 

If

 

unavailable,

 

an

 

FI

 

switch

 

with

 

maximum

 

operating

 

current

 

of

 

30

 

mA

 

has

 

to

 

be

 

connected.

 

 

 

These

 

installation

 

and

 

operating

 

guidelines

 

have

 

to

 

be

 

read

 

carefully

 

before

 

installing

 

the

 

product.

 

The

 

instructions

 

mentioned

 

have

 

to

 

be

 

followed

 

strictly.

 

Modifications

 

to

 

the

 

product

 

are

 

not

 

permitted,

 

otherwise

 

the

 

warranty

 

becomes

 

void.

 

 

The

 

following

 

points

 

have

 

to

 

be

 

strictly

 

observed

 

during

 

the

 

installation

 

and

 

operation:

  

 

Check

 

the

 

product

 

before

 

installation

 

for

 

any

 

visible

 

defects.

 

If

 

defects

 

are

 

present,

 

then

 

the

 

product

 

must

 

not

 

be

 

installed.

 

Damaged

 

products

 

can

 

be

 

dangerous.

  

 

Installations

 

at

 

the

 

mains

 

water

 

pipeline

 

system

 

have

 

to

 

be

 

only

 

performed

 

by

 

a

 

qualified

 

installation

 

company.

  

 

A

 

floor

 

drain

 

has

 

to

 

be

 

provided

 

near

 

the

 

installation

 

site,

 

which

 

can

 

collect

 

inadvertent

 

water

 

discharges

 

(i.e.

 

pump

 

defects,

 

pipe

 

breakages,

 

etc.)

 

and

 

prevent

 

water

 

damage

 

inside

 

the

 

building.

  

 

The

 

mason

 

work

 

behind

 

the

 

water

handling

 

unit

 

must

 

be

 

protected

 

from

 

water

 

damage

 

(i.e.

 

with

 

water

resistant

 

coating).

  

 

Make

 

sure

 

that

 

the

 

existing

 

emergency

 

overflows

 

are

 

connected

 

and

 

adequately

 

sized.

  

 

Remove

 

the

 

mains

 

electrical

 

plug

 

if

 

you

 

will

 

be

 

away

 

for

 

more

 

than

 

24

 

hours.

 

 

Close

 

the

 

mains

 

water

 

line

 

at

 

the

 

inlet

 

of

 

the

 

device

 

if

 

you

 

will

 

be

 

away

 

for

 

more

 

than

 

24

 

hours.

  

 

All

 

products

 

must

 

be

 

regularly

 

inspected

 

to

 

maintain

 

proper

 

condition.

 

The

 

minimum

 

inspection

 

interval

 

is

 

mentioned

 

in

 

the

 

maintenance

 

section.

  

 

Electrical

 

devices

 

may

 

be

 

hazardous

 

for

 

children.

 

Therefore

 

children

 

always

 

have

 

to

 

be

 

kept

 

away

 

from

 

the

 

product.

 

Do

 

not

 

let

 

children

 

play

 

with

 

the

 

product.

  

 

Do

 

not

 

install

 

the

 

water

handling

 

units

 

in

 

locations

 

where

 

the

 

temperature

 

may

 

drop

 

below

 

0°C.

  

 

Do

 

not

 

install

 

any

 

electrical

 

products

 

in

 

flood

prone

 

areas.

  

 

The

 

operator

 

is

 

responsible

 

for

 

adherence

 

of

 

the

 

safety

 

and

 

installation

 

guidelines.

 

 

Summary of Contents for SEPAMAT F

Page 1: ...WATER WE RE IN OUR ELEMENT www intewa com SEPAMAT F Installation and user manual...

Page 2: ...9 5 1 Components of the pump controller 9 5 2 Components of the basic controller 10 5 3 Components of the multistage pump 12 5 4 Components of the supply container 13 6 Installation instructions 14 6...

Page 3: ...protects drinking water against contamination caused by backflow of pollutants from the consumer point of use System separation is installed between the municipal drinking water supply and one or more...

Page 4: ...ns at the mains water pipeline system have to be only performed by a qualified installation company A floor drain has to be provided near the installation site which can collect inadvertent water disc...

Page 5: ...T F_manual_Vers 2 8f_en 4 3 Scope of delivery Separation unit SEPAMAT F Wall mounting material installation and user manual Standard accessory A Mains water connection Standard accessory B Pressure li...

Page 6: ...current 4 A 5 8A Motor capacitor 12 5 F 20 F Max discharge pressure 4 5 bar 5 5 bar Max flow rate 80 l min 110 l min Noise level ca 60 dBA ca 65 dBA Pump start up pressure 1 0 2 2 bar adjustable facto...

Page 7: ...l pump SEPAMAT F20 40 2 Pump terminal box with basic controller 3 Vent cock 4 Pressure line shut off valve 3 4 female 5 Pump controller 6 Supply container 7 Stopcock for mains water 3 4 female 8 Mains...

Page 8: ...secure separation of processed water from the mains water line which is integrated into the SEPAMAT F 4 1 2 3 Mains water separation device Type AB as per DIN EN 1717 Certification separation device a...

Page 9: ...mity with the relevant Union harmonization legislation 2006 42 EU Maschinenrichtlinie 2006 42 EU Directive Machinery 2014 30 EU EMV Richtlinie 2014 30 EU Directive relating to electromagnetic compatib...

Page 10: ...is recommended that only experienced professionals use the pressure setting option The pump start up pressure is set to 1 5 bar by default That means the pump switches on when the system pressure fall...

Page 11: ...troller year of manufacture from 04 2021 5 2 Components of the basic controller The basic controller will be found in the terminal box of the pump 1 where all the electrical components of the SEPAMAT...

Page 12: ...r brown N Pump controller blue Pump controller black N Pump blue L1 Pump brown 12 13 14 15 16 17 18 19 20 21 22 SS PE PU PE LP PE NE br SS brn SS bl KH schw KH gr n KH rt LP bl LP brn free Protective...

Page 13: ...CAPACITOR 47 CAPACITOR ZBR 1 ZBR 1 pcs 16 16 O RING NOZZLE 1 pc 1 84 84 PLUG FRONT 1 pc 1 88 88 SHUTTER 1 pc 1 490 490 RUBBER SPACER 1 pc 1 89 89 SPRING SHUTTER 1 pc 1 370 370 SELF PRIMING SUCTION 1 R...

Page 14: ...rizontal lever is factory set at 85 mm by the SMT 20 float valve and 90 mm by the SMT40 float valve Note If an overflow occurs due to continuous dripping from the valve the valve must be decalcified s...

Page 15: ...is mounted on a wall with the supplied wall bracket The lid and lateral distances indicated should be adhered to when mounting to provide clear maintenance access The SEPAMAT F is wall mounted in suc...

Page 16: ...ose and stopcock Screw the gland screw into the container connection and carefully tighten with a fixed wench Note The flexible hose must not be overtightened as this may interfere with the internal f...

Page 17: ...line set is connected to the pump controller The flexible hose and the shut off valve then connect to the pressure line set and the pressure line 6 4 Connecting the emergency overflow The SEPAMAT F ha...

Page 18: ...entering the SEPAMAT F The position of the backwater level determines the type of line a Backwater level above the emergency overflow drainage height of the supplemental supply container Connection of...

Page 19: ...automatically over the mains water tank In this case the pump cannot be manually filled with water 2 Close the pressure line shut off valve 3 Open the air vent hold a bucket of water under the air ven...

Page 20: ...l light up see section 5 1 The system pressure can be read on the pressure gauge of the pump controller The Automatic Mode or Maintenance Mode can be set via the mode selecting switch 8 Trouble shooti...

Page 21: ...aphragm chamber as well 24 hours exposure time If the dripping continues after maintenance then the valve must be replaced 10 Spare parts Description Figure No see section 4 1 Bestellbezeichnung Multi...

Page 22: ...tails at INTEWA GmbH Auf der H ls 182 52068 Aachen Tel 0049 241 96605 0 Fax 0049 241 96605 10 Email info intewa de Internet www intewa de For customers in other countries For any queries ordering of s...

Reviews: