background image

 

 

SEPAMAT

 

F_manual_Vers.2.8f_en

 

20

 

Flow

 

rate

 

is

 

too

 

low

 

or

 

pump

 

supplies

 

no

 

water

 

 

Too

 

little

 

or

 

no

 

water

 

inflow

 

to

 

the

 

priming

 

tank

 

 
 

 

Test

 

the

 

mains

 

water

 

pressure,

 

remove

 

the

 

filter

 

sieve

 

in

 

the

 

mains

 

water

 

valve

 

and

 

clean

 

(see

 

section

 

5.3)

 

Only

 

half

 

of

 

the

 

maximum

 

pump

 

pressure

 

is

 

achieved

 

 

Defective

 

air

 

separator

 

or

 

diffuser/impeller

 

 

 

Replace

 

air

 

separator

 

or

 

diffuser/impeller

 

 
 
 
 
 

9

 

Maintenance

 

 

Every

 

3

 

months

 

a

 

visual

 

and

 

operations

 

test

 

must

 

be

 

completed.

 

 

If

 

the

 

mains

 

water

 

valve

 

continuously

 

drips,

 

then

 

this

 

must

 

be

 

decalcified.

 

Therefore,

 

remove

 

the

 

entire

 

valve

 

from

 

the

 

tank

 

and

 

place

 

it

 

in

 

a

 

decalcifying

 

solution

 

(citric

 

acid)

 

so

 

that

 

the

 

inlet

 

and

 

outlet

 

are

 

fully

 

submerged.

 

Move

 

the

 

floating

 

arm

 

several

 

times

 

so

 

that

 

the

 

decalcifying

 

solution

 

penetrates

 

the

 

valve

 

diaphragm

 

chamber

 

as

 

well

 

(24

 

hours

 

exposure

 

time).

 

If

 

the

 

dripping

 

continues

 

after

 

maintenance,

 

then

 

the

 

valve

 

must

 

be

 

replaced.

 

 
 
 
 

10

 

Spare

 

parts

 

 

Description

 

Figure

 

No.

 

(see

 

section

 

4.1)

 

Bestellbezeichnung

 

Multistage

 

centrifugal

 

pump

 

SEPAMAT

 

F

 

20

 

[1]

 

RMF

P20

 

Multistage

 

centrifugal

 

pump

 

SEPAMAT

 

F

 

40

 

[1]

 

RMF

P40

 

Basic

 

controller

 

[2]

 

RMF

BPL

 

Pump

 

controller

 

BRIO

 

[5]

 

RMF

PST

 

BRIO

 

Supply

 

container

 

[6]

 

RMF

B

 

Floating

 

valve

 

for

 

Supply

 

container

 

[8]

 

RMF

NSP

 

Spare

 

parts

 

for

 

pumps

 

SEPAMAT

 

F

 

20

 

/

 

40

 

 

see

 

section

 

5.2

 

 
 
 
 

11

 

Warranty

 

/

 

Guarantee

 

 

INTEWA

 

GmbH

 

guarantees

 

this

 

unit

 

for

 

24

 

months

 

from

 

the

 

date

 

of

 

purchase.

 

Kindly

 

keep

 

the

 

sales

 

receipt

 

as

 

proof

 

of

 

purchase.

 

Within

 

the

 

guarantee

 

period,

 

INTEWA

 

GmbH

 

reserves

 

the

 

right

 

to

 

either

 

repair

 

or

 

replace

 

faulty

 

parts

 

at

 

its

 

own

 

discretion.

  

The

 

warranty

 

does

 

not

 

cover

 

any

 

damage

 

due

 

to

 

improper

 

use,

 

wear

 

and

 

tear,

 

or

 

intervention

 

by

 

third

 

parties.

 

The

 

warranty

 

does

 

not

 

cover

 

any

 

defects

 

which

 

may

 

only

 

minutely

 

affect

 

the

 

value

 

or

 

usability

 

of

 

the

 

device.

 

Summary of Contents for SEPAMAT F

Page 1: ...WATER WE RE IN OUR ELEMENT www intewa com SEPAMAT F Installation and user manual...

Page 2: ...9 5 1 Components of the pump controller 9 5 2 Components of the basic controller 10 5 3 Components of the multistage pump 12 5 4 Components of the supply container 13 6 Installation instructions 14 6...

Page 3: ...protects drinking water against contamination caused by backflow of pollutants from the consumer point of use System separation is installed between the municipal drinking water supply and one or more...

Page 4: ...ns at the mains water pipeline system have to be only performed by a qualified installation company A floor drain has to be provided near the installation site which can collect inadvertent water disc...

Page 5: ...T F_manual_Vers 2 8f_en 4 3 Scope of delivery Separation unit SEPAMAT F Wall mounting material installation and user manual Standard accessory A Mains water connection Standard accessory B Pressure li...

Page 6: ...current 4 A 5 8A Motor capacitor 12 5 F 20 F Max discharge pressure 4 5 bar 5 5 bar Max flow rate 80 l min 110 l min Noise level ca 60 dBA ca 65 dBA Pump start up pressure 1 0 2 2 bar adjustable facto...

Page 7: ...l pump SEPAMAT F20 40 2 Pump terminal box with basic controller 3 Vent cock 4 Pressure line shut off valve 3 4 female 5 Pump controller 6 Supply container 7 Stopcock for mains water 3 4 female 8 Mains...

Page 8: ...secure separation of processed water from the mains water line which is integrated into the SEPAMAT F 4 1 2 3 Mains water separation device Type AB as per DIN EN 1717 Certification separation device a...

Page 9: ...mity with the relevant Union harmonization legislation 2006 42 EU Maschinenrichtlinie 2006 42 EU Directive Machinery 2014 30 EU EMV Richtlinie 2014 30 EU Directive relating to electromagnetic compatib...

Page 10: ...is recommended that only experienced professionals use the pressure setting option The pump start up pressure is set to 1 5 bar by default That means the pump switches on when the system pressure fall...

Page 11: ...troller year of manufacture from 04 2021 5 2 Components of the basic controller The basic controller will be found in the terminal box of the pump 1 where all the electrical components of the SEPAMAT...

Page 12: ...r brown N Pump controller blue Pump controller black N Pump blue L1 Pump brown 12 13 14 15 16 17 18 19 20 21 22 SS PE PU PE LP PE NE br SS brn SS bl KH schw KH gr n KH rt LP bl LP brn free Protective...

Page 13: ...CAPACITOR 47 CAPACITOR ZBR 1 ZBR 1 pcs 16 16 O RING NOZZLE 1 pc 1 84 84 PLUG FRONT 1 pc 1 88 88 SHUTTER 1 pc 1 490 490 RUBBER SPACER 1 pc 1 89 89 SPRING SHUTTER 1 pc 1 370 370 SELF PRIMING SUCTION 1 R...

Page 14: ...rizontal lever is factory set at 85 mm by the SMT 20 float valve and 90 mm by the SMT40 float valve Note If an overflow occurs due to continuous dripping from the valve the valve must be decalcified s...

Page 15: ...is mounted on a wall with the supplied wall bracket The lid and lateral distances indicated should be adhered to when mounting to provide clear maintenance access The SEPAMAT F is wall mounted in suc...

Page 16: ...ose and stopcock Screw the gland screw into the container connection and carefully tighten with a fixed wench Note The flexible hose must not be overtightened as this may interfere with the internal f...

Page 17: ...line set is connected to the pump controller The flexible hose and the shut off valve then connect to the pressure line set and the pressure line 6 4 Connecting the emergency overflow The SEPAMAT F ha...

Page 18: ...entering the SEPAMAT F The position of the backwater level determines the type of line a Backwater level above the emergency overflow drainage height of the supplemental supply container Connection of...

Page 19: ...automatically over the mains water tank In this case the pump cannot be manually filled with water 2 Close the pressure line shut off valve 3 Open the air vent hold a bucket of water under the air ven...

Page 20: ...l light up see section 5 1 The system pressure can be read on the pressure gauge of the pump controller The Automatic Mode or Maintenance Mode can be set via the mode selecting switch 8 Trouble shooti...

Page 21: ...aphragm chamber as well 24 hours exposure time If the dripping continues after maintenance then the valve must be replaced 10 Spare parts Description Figure No see section 4 1 Bestellbezeichnung Multi...

Page 22: ...tails at INTEWA GmbH Auf der H ls 182 52068 Aachen Tel 0049 241 96605 0 Fax 0049 241 96605 10 Email info intewa de Internet www intewa de For customers in other countries For any queries ordering of s...

Reviews: