ELECTRICAL REQUIREMENTS:
The low voltage Control Wires from your Central Vacuum Cleaner
have mostly an output of 24volt AC.
: some Central Vacuums have 24volt DC output. If your vacuum
does not start --- just reverse the 2 wires at the wire nuts.
(reverse the polarity).
Note
Installation:
into a kitchen cabinet kick-board or room base
board flush with the floor.
IMPORTANT: DISCONNECT THE POWER TO THE CENTRAL
VACUUM BEFORE INSTALLING
WITH TRIM-PLATE INSTALLED:
1) Your VacPort is supplied with a Trim-Plate in case you need more
height to reach into the cut-out. It is also used as a template to mark
the cut-out. See STEP1. The
opening is 6-1/8”wide x 2-1/2”
2) After cutting the hole, STEP2, attach the Trim-Plate with the 2 pan
head screws in one of the outer holes on each side, see STEP3.
4) If you do not need the Trim-Plate, attach the VacPort directly to the
wall with the 2 flat head screws, see STEP4. Keep Trim-Plate for future
reference.
5) See next page for wire
Connections.
minimum
3) Connect the VacPort to your central vacuum with 2” diameter flex-hose.
WITHOUT TRIM-PLATE INSTALLED:
2