InterVac A900 Installation And Operating Manual Download Page 2

ELECTRICAL REQUIREMENTS:

The low voltage Control Wires from your Central Vacuum Cleaner

have mostly an output of 24volt AC.

: some Central Vacuums have 24volt DC output. If your vacuum

does not start --- just reverse the 2 wires at the wire nuts.
(reverse the polarity).

Note

Installation:

into a kitchen cabinet kick-board or room base

board flush with the floor.

IMPORTANT: DISCONNECT THE POWER TO THE CENTRAL

VACUUM BEFORE INSTALLING

WITH TRIM-PLATE INSTALLED:
1) Your VacPort is supplied with a Trim-Plate in case you need more

height to reach into the cut-out. It is also used as a template to mark
the cut-out. See STEP1. The

opening is 6-1/8”wide x 2-1/2”

2) After cutting the hole, STEP2, attach the Trim-Plate with the 2 pan

head screws in one of the outer holes on each side, see STEP3.

4) If you do not need the Trim-Plate, attach the VacPort directly to the

wall with the 2 flat head screws, see STEP4. Keep Trim-Plate for future
reference.

5) See next page for wire

Connections.

minimum

3) Connect the VacPort to your central vacuum with 2” diameter flex-hose.

WITHOUT TRIM-PLATE INSTALLED:

2

Summary of Contents for A900

Page 1: ...MODEL A910 without LED IF YOU SHOULD HAVE ANY QUESTIONS OR EXPERIENCE A PROBLEM WITH YOUR INTERVAC PRODUCT PLEASE CALL OUR CUSTOMER SERVICE DEPT AT 1 888 499 1925 DO NOT RETURN THIS PRODUCT TO THE STORE OR DEALER This unit should be installed by a qualified technician InterVac Design Corp Phone 772 463 1400 USA Canada toll free 888 499 1925 www com 2939 SW 42nd Avenue Palm City FL 34990 intervacde...

Page 2: ...ATE INSTALLED 1 Your VacPort is supplied with a Trim Plate in case you need more height to reach into the cut out It is also used as a template to mark the cut out See STEP1 The opening is 6 1 8 wide x 2 1 2 2 After cutting the hole STEP2 attach the Trim Plate with the 2 pan head screws in one of the outer holes on each side see STEP3 4 If you do not need the Trim Plate attach the VacPort directly...

Page 3: ... a black threaded pipe coupling Do not glue this coupling just twist and press fit into elbow check if you still can slide the VacPort with the flex hose attached in or out of the cut out 2 with pipe coupling push black threaded coupling directly into pipe coupling 3 with the flexible hose you can either connect the flexible hose directly with a hose clamp to the VacPort s pipe or connect with the...

Page 4: ...hreaded coupling 3 into the pipe coupling 5 4 Connect the LOW voltage wire under screw heads NOT under Big Washer The door is held open by 2 small magnets Screw hole to attach VacPort to wall VacPort Model A910 Without LEDs Wall Opening location Pin 1 Remove old dust pan from the wall 2 Use the same 2 screws and attach Trim Plate use the holes A from the removed VacPan use the holes B from the rem...

Reviews: