background image

1

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

MODELS

INSTALLATION
INSTRUCTIONS

RETAIN THESE INSTRUCTIONS

FOR FUTURE REFERENCE

FOR YOUR SAFETY:  Do not store or use gasoline
or other flammable vapors or liquids in the vicin-
ity of this or any other appliance.

FOR YOUR SAFETY:  What to do if you smell gas:

• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• DO NOT use any phone in your building.
• Immediately call your gas supplier from a

neighbor’s phone. Follow your gas suppliers
instructions.

• If your gas supplier cannot be reached, call the

fire department.

Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.

POUR VOTRE SÉCURITÉ:  Ne pas entreposer ni utiliser
d'essence ni d'autre vapeurs ou liquides inflammables
dans le voisinage de cet appareil ou de tout autre
appareil.

POUR VOTRE SÉCURITÉ:  Que faire si vous sentez une
odeur de gaz:

• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucun interrupteur.  Ne pas vous servir

des téléphones se trouvant dans le batiment où
vous vous trouvez.

• Evacuez la piéce, le bâtiment ou la zone.
• Appelez immédiatement votre fournisseur de gaz

depuis un voisin.  Suivez les instructions du
fournisseur.

• Si vous ne pouvez rejoindre le fournisseur de gaz,

appelez le service dos incendies.

L'installation et service doit être exécuté par un qualifié
installeur, agence de service ou le fournisseur de gaz.

AVERTISSEMENT: ASSUREZ-VOUS DE BIEN SUIVRE
LES INSTRUCTIONS DONNÉ DANS CETTE NOTICE POUR
RÉDUIRE AU MINIMUM LE RISQUE D'INCENDIE OU
POUR ÉVITER TOUT DOMMAGE MATÉRIEL, TOUTE
BLESSURE OU LA MORT.

WARNING: IF THE INFORMATION IN THIS MANUAL
IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING PROPERTY DAM-
AGE, PERSONAL INJURY OR LOSS OF LIFE.

DESIGNER  DIRECT VENT

MULTI-OPEN

VENTED GAS FIREPLACE HEATERS - DIRECT VENT MODELS
P/N 800,021M  REV.  A  01/2002

WH Report No. J20006712

This appliance may be installed as an OEM instal-
lation in a manufactured home (USA only) or
mobile home and must be installed in accordance
with the manufacturer's instructions and the manu-
factured home construction and safety standard,
Title 24 CPF, Part 3280 or Standard  for Installation
in Mobile Homes, CAN/CSA Z240 MH.
This appliance is only for use with the type(s) of
gas indicated on the rating plate.  A conversion
kit is supplied with the appliance.

t

l

o

v

i

l

l

i

M

s

l

e

d

o

M

M

N

T

S

M

D

2

-

M

N

F

P

M

D

2

-

f i r e - p a r t s . c o m

Summary of Contents for Millivolt DMPFNM-2

Page 1: ...lez imm diatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service dos incendies L installationetse...

Page 2: ...These vented gas fireplace heaters are sealed combustion air circulating gas fireplaces de signed for residential applications These ap pliances must be installed with the Secure Vent and or Secure F...

Page 3: ...s of the local authorities having jurisdiction and in the USA the latest edition of the National Fuel Gas Code ANSI Z223 1 or in Canada the latest edition of the CAN1 B149 1 and 2 codes WARNING FAILUR...

Page 4: ...ion When the unit is installed with one side flush with a wall the wall on the other side of the unit must not extend beyond the front edge of the unit In addition whentheunitisinstalledinthemiddle of...

Page 5: ...Circuit Wiring Step 5 page 21 Make connection to gas supply Step 6 page 22 Install the log set ver miculite and ceramic fiber chunks Step 7 page 22 Checkout appliance op eration Step 8 page 22 Instal...

Page 6: ...cm minimum H not be installed above a gas service meter regulator assembly within 3 feet 91 4 cm horizontally from the center line of the gas service regulator I clearance to gas service regulator ve...

Page 7: ...LBOWS inches millimeters 7 178 5Z 130 12Z 308 6Z v 159 A Minimum Framing Stud Size is 2x4 41Z x 1054 43B 1108 This dimension can be reduced to 41 inches 1041 mm This results in 0 in 0 mm clearance bet...

Page 8: ...stalled vent seal cap and vent cover plate see Figures 13 and 14 on page 9 in each flue outlet The vent seal cap is not shown in this figure DMPFNM 2 Peninsula 12 305 10 254 TOP VIEW 40Z 1019 3Z x 89...

Page 9: ...being used from inside the firebox loosen the two screws in the keyhole slots of the cover plate and remove the remaining two cover plate securing screws Re move and discard the cover plate Reinstall...

Page 10: ...9 0 0 1 5 5 2 3 5 2 1 7 2 0 0 0 0 7 7 0 3 3 5 7 2 1 0 0 0 7 8 6 3 3 8 2 0 1 0 0 7 8 5 4 3 5 7 8 2 0 0 0 0 1 0 0 1 5 9 4 3 5 2 1 9 2 1 0 0 0 1 0 1 1 2 7 3 1 3 0 0 0 0 8 8 5 6 7 3 5 7 3 1 3 1 0 0 0 8 9...

Page 11: ...See Fig ure 21 for pitched roofs or flat roofs with flat ceilings or Figure 22 for pitched roofs with cathedral ceilings FIGURE 22 Note Trim Thimble Extension To Desired Length And Pitch At The Roof...

Page 12: ...e Support the vertical portion of the venting system every 8 feet 2 4m above the fireplace vent outlet One method of support is by utiliz ing field provided support straps conventional plumber s tape...

Page 13: ...hen using Secure Flex use Firestop Spacer SF4 5BF Figure 30 Rear Vent ONE 90 DEGREE ELBOW Figure 29 Top Vent STRAIGHT Figure 31 Top Vent TWO 90 DEGREE ELBOWS VERTICAL VENT FIGURES TABLES Note Secure V...

Page 14: ...M V m u m i x a M H H H 1 m u m i x a M t e e f m t e e f m t e e f m 1 5 0 3 0 2 0 1 6 0 5 2 5 1 2 0 1 6 0 4 2 2 1 0 1 1 3 3 4 1 9 0 6 6 8 1 5 1 5 6 4 4 2 2 1 8 8 4 2 0 2 2 6 V V 1 H H 1 x a M m 4 2...

Page 15: ...an opening 10 x 10 267 mm x 267 mm inside dimensions about this center refer to Figure 18 on page 11 G Support the vertical run sections See section E on page 12 H Change vent direction At transition...

Page 16: ...ng as described in Step B Assemble the vent system to point where the terminus of the last section is within 7 in 191 mm to 11 in 298 mm inboard of the exterior surface to which the SV4 5 HTS terminat...

Page 17: ...lex use Firestop Spacer SF4 5HF E L B A T F w o b l e e e r g e d 0 9 e n 0 V x a M m 4 1 9 0 t e e f 3 H Figure 38 Rear Vent NO ELBOWS Figure 39 Top Vent ONE 90 DEGREE ELBOW ELBOW CONNECTION AT APPLI...

Page 18: ...l Firestop Spacer SV4 5HF Ceiling Firestop Spacer SV4 5BF Note When using Secure Flex use Firestop Spacer SF4 5BF V H H1 Wall Firestop Spacer SV4 5HF Wall Firestop Spacer SV4 5HF When using Secure Fle...

Page 19: ...0 3 0 5 2 5 1 2 0 1 6 0 0 1 1 3 3 4 1 9 0 5 1 5 6 4 4 2 2 1 0 2 2 6 H H 1 x a M m 2 6 t e e f 0 2 V V 1 H H 1 x a M m 4 2 1 t e e f 0 4 V H2 H1 H Wall Firestop Spacer SV4 5HF When using Secure Flex u...

Page 20: ...r clock wise running the dimples down and along the incline channels until they seat at the end of the channels B Install the Outer Flex Pipe 1 Installthelargegearclamplooselyaround the outer flexible...

Page 21: ...x Reducer Gas Valve Gas Flex Line Connector Figure 49 Figure 48 GAS CONNECTION Turn on gas supply and test for gas leaks using a soapy water solution Never use an open flame to check for leaks A Mix a...

Page 22: ...instruction labels at tached to the gas control valve To access the label see the procedure on the previous page described for accessing the gas control valve When first lighting the appliance it wil...

Page 23: ...e and sooting Proper flame appearance is a matter of taste Generally most people prefer the warm glow of a yellow to orange flame Appliances operated with air shutter openings that are too large will...

Page 24: ...nter the room It is especially important to insulate outside chase cavity between studs and under floor on which appliance rests if floor is above ground level d e t s i L t n e V e r u c e S s l e d...

Page 25: ...3 t f 2 1 1 0 L 7 8 K R H F S x e l F h t i w t i K r e s i R l e k r o n S d n a x e l F f o n o i t c e s a r e t p a d A s p m a l C r a e G 1 8 K 0 1 P M F S e r u t a r e p m e T i H k c a l B c...

Page 26: ...S SAVOIRLAJURIDICTION SIL INFORMATION DANS CETTE INSTRUCTION N EST PAS SUIVIE EXACTEMENT UN FEU EXPLOSION OU PRODUCTION DE PROTOXYDEDECARBONEPEUTR SULTERLEDOMMAGES CAUSER DE PROPRI T PERTE OU BLESSURE...

Page 27: ...Step 5 Attach manometer to the manifold side pressure test fitting and verify manifold pressurereads10 0incheswatercolumn 2 49 kPa for propane gas Step 6 Refer to Figure 57 and remove the pilot hood a...