ION-E100-HD – User manual
Page 23 of 28
8 Point to Point Connections
Point-to-point connections between an ION-E100-HD and an ION-R100 can be configured using
the device’s web application.
In the ION-E100-HD’s web application, in the
Configuration
section, go to the
Video In
tab and
select «video input 1». Scroll down all the way to the bottom of the configuration page. The last
3 sections are named
Point to Point 1
,
2
and
3
.
Here’s a quick overview of the settings available for a connection:
Enabled: Indicates whether this connection is to be used.
Description: Free-form user description of the connection, not used by the device.
Encoder: Indicates which video feed is to be sent over the point-to-point connection.
Possible values include «H.264 High-Quality» and «H.264 Low-Quality». These values
refer to the encoders configured in previous sections of the same web page.
Destination IP: Address where to send the video. This is usually the address of an ION-
R100. The destination can also be a multicast group address. DNS names are not yet
supported, only IP addresses.
Destination Port: Network port where to send the video. This value must match the port
value in the ION-R100.
Once all the settings have been set, click on
Save
at the bottom of the page to apply them. The
ION-E100-HD then creates or updates the connection as needed.
InterTest, Inc • 303 Route 94 • Columbia, NJ 07832 • 908-496-8008 • [email protected] • www.intertest.com