ION-E100-HD – User manual
Page 11 of 28
5 Understanding LED Status
The following describes the system status LED mappings of the ION-E100-HD:
Normal Operation:
Operating system boot up –
LED is steady orange (max. 30 seconds)
Internal application startup –
LED is flashing orange (2 second interval)
ION-E100-HD system ready –
LED is steady yellow
Media streaming –
LED is flashing yellow (1/2 second interval)
Special Operations:
Identify command received –
LED is flashing orange/yellow
Hardware reload default settings –
LED is flashing rapidly red/yellow
Software watchdog is rebooting the appliance –
LED is flashing rapidly red
Firmware update in progress – LED
is flashing slowly red/yellow
Note:
Under normal operation, the ION-E100-HD takes up to 1-2 minutes to boot up.
InterTest, Inc • 303 Route 94 • Columbia, NJ 07832 • 908-496-8008 • [email protected] • www.intertest.com