10
Jøtul C
550
CB Rockland 139656_02 10/2/14
Mantel Clearances
The installation must conform to the minimum
mantel clearances specified in fig. 7a and the chart
below. These clearances may be reduced with
installation of Jøtul Mantel Heat Shield 156448 as
specified in the chart. Clearance reduction to mantel
construction may also be made in conformance to
NFPA 211 or CAN/CSA B365.
A
B
C
D
E
U.S:
57 3/4” 56 1/4” 54 3/4”
53 1/4” 51 3/4”
CAN:
63 1/2”
62”
60 1/2”
59”
57 1/2”
161.3 cm 157.4 cm 153.7 cm 150 cm 146 cm
U.S. & CAN:
With Mantel Heat Shield 156448
48”
46 1/2”
45”
43 1/2”
42”
127.9 cm 118.1 cm 114.3 cm 110.4 cm 106.6cm
For Stove Serial Numbers
before
11903
General Clearances
These clearances are specified for either the U.S.
or Canada as indicated. Clearances are measured
from the hearth surface, door opening, or
centerline as noted below.
A: Hearth Protection, width from centerline: ..........
......................................................... 18 1/2” (470 mm)
B: Hearth Protection, forward from door opening:
................................... US: 16” / CAN: 20”(508 mm)
C: To Side Trim,
1” max. thickness, from centerline
..
................................................................ 21 3/4”
(552 mm)
D: To Side Room Wall, from centerline:.......................
............................................................. 54” (1372 mm)
E: To Top Trim, 1” max. thickness, from hearth:
......................US: 51 3/4” / CAN: 57 1/2” (1460 mm)
F: To Mantel, 3 1/2” max. depth, from hearth:
......................US: 51 3/4” / CAN: 57 1/2” (1460 mm)
To Mantel, 11 1/2” max. depth, from hearth
....................US: 57 3/4” / CAN: 63 1/2” (1613 mm)
See fig. 7a for clearances with Mantel Heat Shield
.
Minimum Clearances for units with
serial numbers
before
11903
Figure 7a. Mantel Clearance Detail - measured from
the hearth surface to the lowest mantel surface.
These older units may be updated for installation at the reduced clearances on the
preceding page with installation of Jøtul C 550 CB Clearance Reduction Kit 157705.
Figure 6a. Minimum clearance to combustible materials.
For Stove Serial Numbers
before
11879
Serialized labels are located on the shipping crate, firebox floor, and firebox shroud.