9
TABLE 1
TECHNICAL SPECIFICATIONS
Firing rate (USGPH)
0,65
0,75
0,65
0,75
Input (BTU/h)
91 000
105 000
91 000
105 000
Capacity (BTU/h)
70 000
83 000
70 000
83 000
Recovery rate at 37.8°C (100°F) temperature rise*
86 USGPH
100 USGPH
84 USGPH
97 USGPH
Flue draft
BECKETT BURNER AFG-F0 (insertion tube 5 5/8") (3450 rpm)
Low firing rate baffle
YES
n/a
YES
n/a
Static disc, model
3 3/8" # 31646
n/a
3 3/8" # 31646
n/a
Nozzle Delavan - 100 PSIG pump pressure
0.65-80W
n/a
0.65-80W
n/a
RIELLO BURNER 40-F3 (insertion tube 5 5/8")
Nozzle Delavan
n/a
0.65-70A
n/a
0.65-70A
Pump pressure
n/a
135
n/a
135
Combustion air adjustment (turtulator/damper)
n/a
0 / 3.5
n/a
0 / 3.5
GENERAL INFORMATION
Overall dimensions (width x depth x height)
Flue pipe diameter
Tank capacity
Shipping weight
* Maximum operating pressure 150PSI
121 L / 32 US gal
190 L / 50 US gal
77 kg / 171 lbs
120 kg / 264 lbs
20" x 20" x 51"
24" x 24" x 59 1/2"
6"
6"
RATING AND PERFORMANCE
CMO32
CMO50
-0.02" W.C.
-0.02" W.C.