Table of contents

1 General ....................................................................................................................................................................  3

2 Use ...........................................................................................................................................................................  3

3 Special conditions for safe use.............................................................................................................................  3

4 Explanation of symbols for warnings and signal words ....................................................................................  3

5 Safety information ..................................................................................................................................................  4

6 Technical Data ........................................................................................................................................................  4

7 Option BLOCKTHERM ADA with aluminium plate ..............................................................................................  4

8 Installation...............................................................................................................................................................  5

9 Connection..............................................................................................................................................................  5

10 Commissioning.......................................................................................................................................................  7

11 Maintenance............................................................................................................................................................  7

12 Troubleshooting .....................................................................................................................................................  7

13 Deinstallation  .........................................................................................................................................................  7

14 Disposal...................................................................................................................................................................  7

15 Certificate of Conformity .......................................................................................................................................  8

16 Further information and service ...........................................................................................................................  8

Summary of Contents for SL BLOCKTHERM DB.A

Page 1: ...Operating Instructions SL BLOCKTHERM DB A HOM146759307Ien 5 05 02 2020...

Page 2: ...e 3 3 Special conditions for safe use 3 4 Explanation of symbols for warnings and signal words 3 5 Safety information 4 6 Technical Data 4 7 Option BLOCKTHERM ADA with aluminium plate 4 8 Installation...

Page 3: ...sfer coefficient is not less not better than 0 5 W K 2 The connecting cable must have a fixed installation and must be protected mechanically 3 If connection is made in the potentially explosive area...

Page 4: ...60 to 180 C Switching capacity of fault alarm AM 10 A 275 V AC Connecting cable Silicone hose cable notch and oil resistant 3 x 1 5 mm Connecting cable AM Silicone hose cable notch and oil resistant...

Page 5: ...NOT exceed the trigger temperature of the limiter The operating temperatures must be adhered to The connection cable must be permanently installed up to the inlet into the on site junction box taking...

Page 6: ...ent devices with a measured triggering residual current of 30 mA are preferable In an IT system an insulation monit oring device needs to be used which switches off the supply as soon as the insulatio...

Page 7: ...the manufacturer in the factory All components have to be kept clean and free of dust and harmful substances that could lead to excessive temperature rise In the dust Ex area the applicable requireme...

Page 8: ...9 Vers o Corrigida 2 2011 ABNT NBR IEC 60079 31 2014 ABNT NBR IEC 60529 2005 Vers o Corrigida 2 2011 IEC 61000 6 4 2007 A1 2011 Designation NCC 17 0104 X Ex tb IIIC T85 C T100 C T135 C T200 C Db Ex db...