Optional plates

:

• Type “

Standard

”. Without drill pattern

Length x Width x Height

215 x 120 x 15

mm

• Type “

BT

”. With drill pattern for transmitter

Length x Width x Height

230 x 120 x 15

mm

• Type “

BM

”. Compatible with drill pattern in combina-

tion for ADA ENEX

Length x Width x Height

230 x 120 x 15

mm

Technical drawing with dimensions available on request.

8

Installation

NOTICE

Carefully remove

When removing from the packaging and during trans-
port, the connection line must not be stressed or bent.

The label needs to remain legible.

Please make sure that the absolute heat transfer coeffi-
cient  of  the  surrounding  housing  is  not  smaller  than  0.5
W/K.

To  ensure  operational  safety,  the  heater  must  operate
under temperature conditions which will NOT exceed the
trigger temperature of the limiter.

The operating temperatures must be adhered to.

The  connection  cable  must  be  permanently  installed  up
to  the  inlet  into  the  on-site  junction  box,  taking  the  per-
missible bending radius = 5 x outer diameter into consid-
eration.

In  the  dust  Ex  area,  the  applicable  requirements  of
ABNT NBR IEC 60079-14 must be complied with.

Illustration 3: 

Installation example BLOCKTHERM with TAE

and clearance

Additional  installation  material,  such  as  rails  or  panels
and also junction boxes, are not included in the standard
scope of delivery (see Installation accessories) and must
be ordered additionally.

9

Connection

 INFO

The device may only be connected up and secured by a
trained person, taking into account the "rated voltage"
and "rated current" specified on the nameplate.

Where  operating  voltage  =  measured  voltage  (rated
voltage),  then  the  heater  is  at  its  rated  output.  Mains
voltage fluctuations up to 10 % are then permissible.

Each heater with integrated TS thermostat must be pre-
ceded  by  a  10  A  fuse  or  a  motor  protection  switch  with
short-circuit  and  thermal  quick  release  (set  to  10  A)  as

Summary of Contents for SL BLOCKTHERM DB.A

Page 1: ...Operating Instructions SL BLOCKTHERM DB A HOM146759307Ien 5 05 02 2020...

Page 2: ...e 3 3 Special conditions for safe use 3 4 Explanation of symbols for warnings and signal words 3 5 Safety information 4 6 Technical Data 4 7 Option BLOCKTHERM ADA with aluminium plate 4 8 Installation...

Page 3: ...sfer coefficient is not less not better than 0 5 W K 2 The connecting cable must have a fixed installation and must be protected mechanically 3 If connection is made in the potentially explosive area...

Page 4: ...60 to 180 C Switching capacity of fault alarm AM 10 A 275 V AC Connecting cable Silicone hose cable notch and oil resistant 3 x 1 5 mm Connecting cable AM Silicone hose cable notch and oil resistant...

Page 5: ...NOT exceed the trigger temperature of the limiter The operating temperatures must be adhered to The connection cable must be permanently installed up to the inlet into the on site junction box taking...

Page 6: ...ent devices with a measured triggering residual current of 30 mA are preferable In an IT system an insulation monit oring device needs to be used which switches off the supply as soon as the insulatio...

Page 7: ...the manufacturer in the factory All components have to be kept clean and free of dust and harmful substances that could lead to excessive temperature rise In the dust Ex area the applicable requireme...

Page 8: ...9 Vers o Corrigida 2 2011 ABNT NBR IEC 60079 31 2014 ABNT NBR IEC 60529 2005 Vers o Corrigida 2 2011 IEC 61000 6 4 2007 A1 2011 Designation NCC 17 0104 X Ex tb IIIC T85 C T100 C T135 C T200 C Db Ex db...

Reviews: