Operating Instructions CP MEGATHERM D.A HI

HOM160989579Ien-1

Page 4 / 7

INTERTEC-Hess GmbH · Raffineriestr. 8 · 93333 Neustadt/Donau · Germany · 

 +49 9445 9532-0 ·   [email protected]

 CAUTION

Risk of burns from a hot surface

Attainable highest temperatures:

- Max. 160°C with T3 heating systems

- Max. 100°C with T4 heating systems

- Max. 70°C with T5 heating systems

- Max. 50°C with T6 heating systems

Do not touch device during operation! Before working on
the device, allow it to cool down first.

5

Installation accessories

The following are included in the scope of delivery:

Piece

Name

1

Heating unit

4

slide nut/screw plate M6 with spring

4

M 6x45 cheese-head screws with hex socket

If  one  of  the  components  listed  here  is  not  included  in
the scope of delivery, then please contact the manufac-
turer.

6

Technical Data

Protection class

IP66/IP68 1bar/30min

Rated voltage

max. 250 V AC

Permitted operating voltage

max. 275 V AC

Rated current (in compli-

ance with VDE 0298)

max. 10 A

Ambient temperature

- 60 to + 60 °C

Max. permitted operating

temperature

- 60 to + 180 °C

Switching capacity of fault

alarm (AM)

10 A / 275 V AC

Connecting cable

Silicone hose cable, notch-

and oil resistant, 3 x 1,5

mm² Ø8,8 mm

Connecting cable AM

Silicone hose cable, notch-

and oil resistant, 5 x 1,0

mm² Ø8,5 mm

Material

Seawater-proof aluminium,

black anodized

Special  voltages  with  corresponding  power  adjustment
and component selection are possible.

Profile type "T" Height x

Width x Depth

325 x 229 x 60

mm

Profile type "P" Height x

Width x Depth

225 x 229 x 60

mm

 INFO

You will find the precise technical data for your in-
strument on the label.

Temperature class

Rated voltage / Operating voltage

High temperature version

Rated output

Illustration 1: 

Example: CP MEGATHERM DPA 200 T3 HI label

7

Installation

NOTICE

Carefully remove

When removing from the packaging and during trans-
port, the connection line must not be stressed or bent.

For free convection, the heater needs to be installed with
ribs  standing  vertically.  The  minimum  distances  to  the
floor and to devices above it must be complied with. The
label needs to remain legible.

If  an  additional  TAE  thermostat  is  switched  in  series,
then  it  can  be  attached  to  the  surface  of  the  heater
(thermal coupling). The minimum distance also needs to
be adhered to here. Refer to the following drawing.

To  ensure  operational  safety,  the  heater  must  operate
under temperature conditions which will NOT exceed the
trigger temperature of the limiter.

The operating temperatures must be adhered to.

The  connection  cable  must  be  permanently  installed  up
to  the  inlet  into  the  on-site  junction  box,  taking  the  per-
missible bending radius = 5 x outer diameter into consid-
eration.