Interroll Transfer module SH 1400
Maintenance and repair
36
Version 1.0 (06/2022) en
Translation of original operating instructions
Replacing the knife edge
2
2
1
1
3
Replacing the knife edge
1
Screw
3
Center segment
2
Knife edge
WARNING
Risk of injury from crushing and electrocution
Installation and maintenance tasks on a conveyor system while it is in operation can cause
crushing and electric shock.
4
Power down the entire conveyor module and ensure that it cannot be started accidentally.
Requirement:
R
The module is shut down.
4
Remove the module conveyor,
see "Replacing the module conveyor", page 32
4
Remove screws (1) from knife edge (2) and detach old knife edge from center segment (3).
4
Place new knife edge on center segment and fasten with screws.
4
Reattach the module conveyor.