Interroll Transfer module SH 1400
Maintenance and repair
32
Version 1.0 (06/2022) en
Translation of original operating instructions
Replacing the module conveyor
2
3
4
1
1
Replacing the module conveyor
1
Connecting brace
2
Center segment
3
Module conveyor
4
Drive roller
WARNING
Risk of injury from crushing and electrocution
Installation and maintenance tasks on a conveyor system while it is in operation can cause
crushing and electric shock.
4
Power down the entire conveyor module and ensure that it cannot be started accidentally.
Requirement:
R
The module is shut down.
4
Drive the connecting rod out of the module conveyor (2) with a hammer and mandrel.
4
Thread out the old module conveyor mat and properly dispose of it.
4
Feed the new module conveyor (2) around the drive roller (4) and the center segment (3)
and thread it in inside the connecting braces (1).
4
Combine the module conveyor without sagging and drive in the connection rod using a
hammer and mandrel.