Assistance in the event of faults
Power
Ready
Net run
Fault
Meaning
Priority
-
-
-
Flashes x6
Voltage error, overvoltage
4
-
-
-
Flashes x7
Temperature in the MultiControl too high.
6
-
-
-
Flashes x8
Overload protection for the brake resistor
active.
7
-
-
-
Flashes x9
Handshake communication interrupted.
See instructions on ZPA and ZPA+
applications.
-
-
-
Flashes x10
No connection to the neighbouring
devices. See instructions on ZPA and ZPA+
applications.
-
-
-
Flashes x11
A configured neighbouring device has an
error (see ZPA+, "RemoteEmergency" in
the error log)
If several errors occur at the same time, only the error with the highest priority is displayed.
¾
To eliminate the errors, refer to „Troubleshooting“ on page 59.