Assembly and installation
Connecting the sensors
Four sensors and four additional inputs or outputs (AUX I/O) can be connected at connections “Sensor 1, I/O 1” to
“Sensor 4, I/O 4”. PNP or NPN sensors as well as sensors with N/C or N/O contact can be used. The sensor type and
the function of the additional I/Os can be parametrised (see „Digital I/O - Settings“ on page 42). A Y-cable can be
used to connect a sensor and an input/output at the same connection (see „Accessories“ on page 66).
2
1
3
4
1
+24 V
3
Earth
2
AUX I/O
4
Sensor input
¾
Seal any unused connections with an M8 blind cap to achieve protection rate IP54.
NOTE
Connections are not short circuit-proof
In the event of a short circuit, particularly between Pin 1 and Pin 3, the internal fuse (PTC) in the MultiControl trips.
Standard operation can be resumed once the internal fuse has cooled down.
¾
Ensure the correct polarity.
The inputs and outputs are not galvanically separated.
Characteristic values for the inputs
Input voltage
0 V to 24 V DC
Input resistance
≥ 15 kΩ
Switching thresholds
≥ 15 V "High"
≤ 5 V "Low"
Summary of Contents for MultiControl AI
Page 68: ...68 of 140 Version 2 5 11 2020 UL Translation of the original operating manual Appendix ...
Page 74: ...74 sur 140 Version 2 5 11 2020 UL Traduction de la notice d utilisation originale ...
Page 136: ...136 sur 140 Version 2 5 11 2020 UL Traduction de la notice d utilisation originale Annexe ...
Page 137: ...Version 2 5 11 2020 UL Traduction de la notice d utilisation originale 137 sur 140 Notes ...
Page 138: ...138 sur 140 Version 2 5 11 2020 UL Traduction de la notice d utilisation originale Notes ...
Page 139: ......
Page 140: ...INSPIREDBY EFFICIENCY 2020 INTERROLL EN FR UL 11 2020 Version 2 5 1119087 ...