20
12 - TROUBLE SHOOTING
(FOR QUALIFIED PERSONNEL)
TROUBLE
CAUSE
REMEDY
The pump is running but
maximum pressure is
not obtained
Air sucked into pump
Worn or dirty valves
Unloader packings worn
Nozzle worn or incorrect
Piston packings worn
Dirty filter
Check suction hose and fittings
Clean or replace
Check and/or replace
Check and/or replace
Check and/or replace
Check and/or clean
Fluctuating pressure
Damaged, dirty or clogged valves
Air is being sucked
Worn packings
Dirty filter
Check, clean and/or replace
Check suction hose and fittings
Check and/or replace
Check and/or clean
Pressure decreases
Worn nozzle
Dirty or stuck valves
Bypass packings worn
Piston packing worn
Dirty filter
Substitute nozzle
Check, clean and/or replace
Check and/or replace
Check and/or replace
Check and/or clean
Excessive noise
Air suction
Damaged, dirty or stuck valves
Worn bearings
Water temperature too high
Dirty filter
Check suction hose and fittings
Check, clean and/or replace
Check and/or replace
Lower water temperature to
under 60°C
Check and/or clean
Presence of water in oil
Piston packings and oil seals worn
High air humidity
Check and/or replace
Change oil twice as frequently
as that advised
Water dripping from under pump
Piston packings worn
Packing o-rings worn
Check packings
Replace O.R.
Oil leakage
Oil seals worn
Replace oil seal
The motor does not start when
switched on
The plug is not well connected
No power supply
Check plug, cord and switch
The motor stops
The thermal protector has tripped
due to overheating
- Release the gun trigger to the
off position and engage the
safety lock.
- Turn the selector knob to the
"0" (OFF) position in order to
avoid accidental restarts.
- Check that the mains voltage is
the prescribed one.
- Let the motor cool for a few
minutes before restarting the
unit, by turning the switch to the
"I" (ON) position and pulling the
gun trigger. If the unit does not
start, bring back the switch to
the "0" (OFF) position.
- Repeat the operation until the
unit starts.
The motor hums but does not run
when turned on
System voltage is lower to the
minimum advised
The pump is stuck or frozen
Extension cord incorrect
Check that your power source
is adequate
See page 17
Check the extension cord
table on page 11
Summary of Contents for TX300
Page 2: ......
Page 92: ...90 1 M...
Page 94: ...92 300 500 3 3 1 4 4 1...
Page 95: ...93 4 2 5 5 1 1 2 1 3 2 A A B 1 2 3...
Page 97: ...95 5 3 1 2 3 MCB 30 30 4 5 300 500 60364 1 1 2 3 4 5 6 7 IEC 60364 1 Zmax 0 11...
Page 98: ...96 5 4 230 240 230 240 400 415 2 20 20 50 50 2 5 4 2 5 5 3 1 UL...
Page 99: ...97 5 5 TX500 10 2 A B 1 2 1 3 4 20 5 6 0 7 0 I 1 4 3 7 2 6 A B...
Page 100: ...98 6...
Page 101: ...99...
Page 102: ...100...
Page 104: ...102 9 50 300 SAE 15W40 0 37 300 1 1 500 B D A A B A c D 10 10 1 Interpump Group...
Page 105: ...103 10 2 10 3...
Page 106: ...104 11 2002 96 RAEE 1 2...
Page 107: ...105 12 60 C I 102 96...
Page 129: ...127...