The equipment you have purchased from International Light, Inc. has been expertly designed and was 
carefully tested and inspected before being shipped. If properly operated in accordance with the instructions 
furnished, it will provide you with excellent service. The equipment is warranted for a period of twelve (12) 
months from date of purchase to be free of defects in material or workmanship. This warranty does not apply 
to damage resulting from improper set up, accident, alteration, abuse, loss of parts or repair by other than 
International Light Technologies. The equipment will be repaired or replaced, at our option, without charge to
the owner for parts or labor incurred in such repair. This warranty shall not apply unless the equipment is 
returned for our examination with all transportation charges prepaid to International Light Technologies, 10 
Technology Drive, Peabody, MA 01960. International Light Technologies has no other obligation or liability in 
connection with said equipment.

ILT5000 Research Radiometer Manual, Rev B, 4/17                                                                                     13 of 13

Summary of Contents for ILT5000

Page 1: ......

Page 2: ...as with warning Page 5 8 Response time Page 5 9 Flash N A Page 5 10 Trigger Page 6 11 Dark and Zero settings Page 6 12 Set up and Installations Page 6 13 System Verifications Page 6 14 Final Verificat...

Page 3: ......

Page 4: ...s illuminated when meter is charging Rear panel of the ILT5000 11 Power switch Turns meter off and on Turn meter ON up position prior to starting the software or connecting to a PC for the first time...

Page 5: ...vides an autorange mechanism allowing it to measure from 10 femptoamps to 1 milliamp of current While autoranging or using the various fixed current ranges settable via the various DataLight software...

Page 6: ...s Installer file with a msi extension When the msi file is executed you are brought through a simple set of Next Next Finish steps At the completion a DataLight folder will be placed on the desk top w...

Page 7: ......

Page 8: ......

Page 9: ...the Detector Current when setcurrentloop command was sent 4 20mA Current is linear in between Manual Current Loop Setting setcurrentloop 0 24 No relationship 4 20mA Current is set to whatever the setc...

Page 10: ...tically determine the appropriate security protocol WEP WPA and WPA2 are supported Set the IP Address This can either be accomplished by a Using DHCP which will automatically fill in the IP Address Ne...

Page 11: ......

Page 12: ......

Page 13: ...pply to damage resulting from improper set up accident alteration abuse loss of parts or repair by other than International Light Technologies The equipment will be repaired or replaced at our option...

Reviews: