Setup - MaxiScan 3300
38
MaxiScan 3010 - Installation Guide
MaxiScan 3010 Network System
Set up the MaxiScan 3010 – online
➊
System power OFF
➋
Connect the MaxiScan 3010 Network System to the PC where EasySet is
installed
power supply
7 – 25 V
RS-232 straight cable
P/N: 0-530062-01
M axiScan 3010
➌
Start EasySet
EasySet
➍
System power ON
When the power is switched on, the MaxiScan 3010 is in configuration mode
(19200, 8, N, 2) and remains in this mode until it receives data from a MaxiScan
unit on the network (when a scanner reads a bar code). Once it has read a bar
code the MaxiScan goes in to default configuration (9600, 7, E, 2).
➎
Set up the MaxiScan 3010 Network System using EasySet:
•
number of slaves (scanners) in the network (default = 10)
•
time of polling delay between slaves