Installation - Input synchronization examples
MaxiScan 3010 - Installation Guide
23
Jumper configuration
To reconfigure the jumpers, unscrew the front and rear panels of the MaxiScan 3010 and slide out the
motherboard.
VOLTAGE
JUMPER
6 to 15V
S4
16 to 24V
S5
25 to 50V *
S6
POWER SUPPLY
DB9 male
SCANNER BUS
DB15 male
SYNCHROS
DB9 female
HOST
DB15 female
S6 S5 S4
* The SI+ signal on the SYNCHROS port accepts up to 50V, however the MaxiScan 3010 is limited to
25V.