![Intermec JD2010 Quick Reference Manual Download Page 12](http://html1.mh-extra.com/html/intermec/jd2010/jd2010_quick-reference-manual_2079152012.webp)
JANUS 2010 Communications Dock Quick Reference Guide
12
Dock Configuration Table
DIP Switches
Dock Port
Port Communications
Cable Interface
1
2
3
4
Network port
Network port talks to JANUS 2010.
RS-232 or RS-422
0
0
1
0
Network port talks to JANUS 2010.
RS-422
0
1
0
0
Network port talks to JANUS 2010.
RS-485
0
1
0
1
Auxiliary port
Auxiliary port talks to JANUS 2010.
RS-232 or RS-422
0
0
1
0
Auxiliary port talks to JANUS 2010.
RS-422
0
1
0
0
Auxiliary port talks to JANUS 2010.
RS-485
0
1
0
1
Both ports
Network port talks to JANUS 2010
and auxiliary port.
RS-232 or RS-422
0
1
1
0
Network port talks to JANUS 2010
and auxiliary port.
RS-422
1
0
0
0
Network port talks to JANUS 2010.
RS-422
1
0
1
0
Network port talks to JANUS 2010.
RS-485
1
0
X
1
Both ports talk to the reader and
each other.
RS-232 or RS-422
1
1
0
0
Both ports talk to the reader and
each other.
RS-422
1
1
1
0
Both ports talk to the reader, but
not each other.
RS-485
1
1
1
1
Note:
X means the DIP switch can be set to 0 or 1
Connecting the Power Supply
The communications dock uses the Intermec Part No. 058399 power supply,
which has a detachable power cord. The power supply operating range is 100
to 240 VAC at 47 to 63 Hz. To connect the power supply, attach the power
supply to the connector on the back panel of the dock and plug the power
supply into an AC outlet.