Intermec EasyCoder PD4—Service Manual
Chapter 13—Interfaces
13.1 RS-232 Serial Interface
Description
The RS-232 serial interface is a bidirectional communication protocol
for distances up to 10 to 15 metres (33 to 49 ft). The communication
parameters can be set in the Setup Mode (see
EasyCoder PD4, User’s Guide
)
or using a
Y
command (see
ESim for EasyCoder PD4 v5.xx, Programmer’s
Reference Manual
) as follows:
Baud rate
4,800 bps
9,600
bps
19,200
bps
38,400
bps
Parity No
parity
Odd
parity
Even
parity
Data length
7 bits
8
bits
Stop bit(s)
1 bit
2
bits
Handshaking is XON/XOFF and RTS/CTS
One line co5 VDC, max 500mA (permanently enabled)
The connector on the printer’s rear plate is a DB-9pin socket.
Signals
Pin
Signal
Meaning
Remark
1
Ex5 VDC
Max. 500mA, permanently enabled
2
TXD
Transmit data
3
RXD
Receive data
4
Not used
5
GND
Ground
6
Not used
7
CTS
Clear to send
8
RTS
Request to send
9
Not used
Summary of Contents for EasyCoder PD4
Page 1: ...Service Manual EasyCoder PD4 Bar Code Label Printer ...
Page 4: ...iv Intermec EasyCoder PD4 Service Manual ...
Page 24: ...14 Intermec EasyCoder PD4 Service Manual Chapter 2 Front Panels ...
Page 36: ...26 Intermec EasyCoder PD4 Service Manual Chapter 5 Media Supply ...
Page 58: ...48 Intermec EasyCoder PD4 Service Manual Chapter 7 Print Mechanism ...
Page 66: ...56 Intermec EasyCoder PD4 Service Manual Chapter 9 Strip Module ...
Page 72: ...62 Intermec EasyCoder PD4 Service Manual Chapter 10 Cutter ...
Page 94: ...84 Intermec EasyCoder PD4 Service Manual Chapter 12 Main Board ...
Page 110: ...100 Intermec EasyCoder PD4 Service Manual Chapter 14 Troubleshooting ...
Page 113: ......