152
ESim v5.12 for EasyCoder PD4—Programmer’s Reference Manual
Appendix A — Error-Handling
Error Types
Classified types of error & status codes for the Error Replies table later in
this appendix.
Type Feature
Generates
Recovered by
A
Minor Error
of command
sequences and
similar.
At Error reporting (cmd
US
): Sets error on print
command and sets Error
LED to solid red.
At no Error reporting (cmd
UN
): sets Ready LED to
green at print command
At Error reporting (cmd
US
):
Press Feed key orsend Reset
command
^@
. Also see cmd
USA
.
At No Error reporting (cmd
UN
): No recover necessary,
already done.
B
Print Stop-
ping Error.
Sets Error LED to solid red
Feed Key or command Reset
^@
.See also command
USB
.
C
Paper End
Stopping
Error.
Sets Error LED to solid red
at print.
Load new media and press
Feed key or send Reset com-
mand
^@
.
D
Error of
printing func-
tionality and
status.
Sets Error LED directly to
red, sometimes blinking.
Manual or automatic (tem-
perature lowered) measure or
send Reset command
^@
.
E
Status
changes.
No LED change.
No recover necessary/Delete
Label from LTS. See also com-
mand
USE
.
F
Unrecoverable
Error.
Sets Error LED directly to
red.
Power Off/Power On or send
Reset command
^@
.
G
Various modes
Not applicable