Chapter 2 — Installing the Forklift Power Supply
Forklift Power Supply Installation Guide
17
7
Twist the shield wire and slide on the 1/8-inch heat shrink
tubing (P/N 321-650-006).
Sliding the Heat Shrink Tubing Onto Twisted Wires
Attaching Heat Shrink Tubing
This kit contains a 15 cm (6 inch) length of 0.95 cm (3/8-inch)
diameter heat shrink tubing (P/N 321-650-006) which you will
cut into three pieces, and a 30 cm (12 inch) length of 0.32 cm
(1/8-inch) diameter heat shrink tubing (P/N 321-050-003) for
the shield wire.
To install heat shrink tubing
1
Crimp terminal rings and fuse holder ends, then position all
heat shrink tubing in the locations shown.
Red and black wires (positive)
Shield wire with heat shrink applied
Strip the cable jacket 30-36 cm (12-14”)
Input power cable
Heat shrink tubing
Green and white wires (negative)
Note:
Make sure to verify the wire connections with an
ohmmeter.
Note:
Make sure that the wires that are to connect the negative
input connect to pins 1 and 2 of the input connector. Then
check that the other two wires connect to pins 3 and 4 of the
input connector.
Note:
You must attach the heat shrink tubing before
terminating the wire ends.