background image

LIMITED ONE YEAR WARRANTY

If within one (1) year from the date of purchase, this product fails due to a defect in material or workmanship, Intermatic Incorporated will repair or replace it, at its sole option, free of 

charge. This warranty is extended to the original household purchaser only and is not transferable. This warranty does not apply to: (a) damage to units caused by accident, dropping or 

abuse in handling, acts of God or any negligent use; (b) units which have been subject to unauthorized repair, opened, taken apart or otherwise modified; (c) units not used in accordance 

with instructions; (d) damages exceeding the cost of the product; (e) sealed lamps and/or lamp bulbs, LED’s and batteries; (f) the finish on any portion of the product, such as surface and/

or weathering, as this is considered normal wear and tear; (g) transit damage, initial installation costs, removal costs, or reinstallation costs.

INTERMATIC INCORPORATED WILL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION 

OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. THIS WARRANTY IS IN LIEU OF ALL OTHER 

EXPRESS OR IMPLIED WARRANTIES.  ALL IMPLIED WARRANTIES, INCLUDING THE WARRANTY OF MERCHANTABILITY AND THE WARRANTY OF FITNESS FOR A 

PARTICULAR PURPOSE, ARE HEREBY MODIFIED TO EXIST ONLY AS CONTAINED IN THIS LIMITED WARRANTY, AND SHALL BE OF THE SAME DURATION AS THE 

WARRANTY PERIOD STATED ABOVE. SOME STATES DO NOT ALLOW LIMITATIONS ON THE DURATION OF AN IMPLIED WARRANTY, SO THE ABOVE LIMITATION MAY 

NOT APPLY TO YOU.
This warranty service is available by either (a) returning the product to the dealer from whom the unit was purchased, or (b) mailing the product, along with proof of purchase, postage 

prepaid to the authorized service center listed below. This warranty is made by: Intermatic Incorporated/After Sales Service/7777 Winn Rd., Spring Grove, Illinois 60081-9698/815-675-7000  

http://www.intermatic.com   Please be sure to wrap the product securely to avoid shipping damage.

Wiring diagram, 3 switch installation:

For 3 or more switch operation,  AN ADDITIONAL WIRE MUST BE ADDED between the load and the timer.  
The jumper wire is not required for these applications.

4 or more switch installation:

For 4 or more switch installations use the preceding 3 switch installation diagram and wire 4-way switches 
between the two 3-way switches.

LINE

BLACK

TIMER

BLUE

LOAD

NEUTRAL

TWO 3-WAY SWITCHES

For existing 3 switch installations replace one 3-way switch with the timer and replace the 4-way switch with a 
3-way switch.

RED

ADDITIONAL WIRE

Other Installations

MULTISWITCH APPLICATIONS USING THE ELECTRONIC TIMER ARE WIRED DIFFERENTLY THAN 

WHEN USING CONVENTIONAL TOGGLE SWITCHES.  READ THE FOLLOWING INSTRUCTIONS 

CAREFULLY.

Special applications

Because of it’s unique “hard contact” switch feature, your timer may be used for applications not previously 
possible for electronic wall timers, such as use with dimmers, use without utility power, use on circuits other 
than 120 volts, controlling relays or contactors, or to control DC voltage (for example in recreational vehicles).  
See instructions above for dimmer applications.  For DC and high voltage applications please note the reduced 
load ratings on product label.  Consult factory for application details.

Multiple timers may be mounted in adjacent junction box slots.  
No derating is required for multiple timers.

Wiring diagram, 2 switch installation (3-way):

NOTE: For new construction or to replace a dimmer switch, a lighted switch, or a 3-way switch without screw  
terminals, a single pole switch can be used at the remote location, as shown below.

LINE

BLACK

TIMER

BLUE

RED

JUMPER

LOAD

NEUTRAL

3-WAY SWITCH

COMMON

Installations including a Dimmer:

•  The load size and type must not exceed the rating of the dimmer.
   (Typically 600 watts, 120 VAC, 60 Hz, incandescent lamps only.)
•  If the dimmer is placed in it’s ‘OFF’ position, the timer cannot operate the lights.
•  If the dimmer is set too low, the lights may not turn back on under timer control.  If necessary, use a
    premium quality dimmer that can be turned on at very low settings.

LINE

BLACK

TIMER

BLUE

RED

DIMMER

LIGHT

NEUTRAL

(Capped, Not Connected)

Multi-switch installation using a dimmer :

 A 3-way dimmer should not be used.  If a multi-switch installation is required, use the following diagram.

LINE

BLACK

TIMER

BLUE

RED

DIMMER

LIGHT

NEUTRAL

REMOTE SWITCH

Note: THE REMOTE SWITCH(ES) MAY NOT FUNCTION RELIABLY WHEN THE ACCUMULATED WIRE 
LENGTH TO THE REMOTE SWITCH(ES) EXCEEDS 30 FEET OR IF THE WIRING TO THE REMOTE 
SWITCH(ES) IS BURIED UNDERGROUND.  Consult factory for details.

Note: Used remote switches from a previous conventional installation may not function reliably with an  
electronic timer.  Try a brand new remote switch if function is intermittent.

158SS12527

TROUBLESHOOTING GUIDE

Timer  does  not  operate,  display  is  dim,  blank  or  unreadable, 
display shows nonsense or ‘lobAt’, or timer operates erratically.

Battery is worn out, missing or is installed backwards, or timer 
was operated while battery was removed.

Install  a  fresh  AAA  size  alkaline  battery  in  the  direction  indi-
cated.  Press RESET button, then reprogram timer.

Timer does not switch but display is normal.

Timer not in AUTO, AUTO RAND(om), or MAN(ual) mode.

Use MODE pushbutton to select the desired operating mode.

Use MODE pushbutton to select AUTO or AUTO RAND

Timer not in AUTO or AUTO RAND(om) mode.

Timer works manually but does not follow scheduled program.

Timer won’t enter the AUTO or AUTO RAND modes when 
MODE button is pushed.

Time of day and/or switching times are not programmed.

Make  sure  time  of  day  and  at  least  one  scheduled  activity  are 
programmed.

Review / Revise ALL 6 ON/OFF switching time pairs by repeat-
edly pushing the ON/OFF/EVENT button while in PGM mode.

Programmed schedule(s) are incorrect.

Use MODE pushbutton to select AUTO mode.

Timer is in AUTO RAND(om) mode (Varies switching times up 
to +/- 15 minutes).

Timer  switches  at  incorrect  times  or  skips  some  switching 
times.

After entering your schedules or the time, then returning to the 
AUTO modes, push the ON/OFF/EVENT button to change the 
load state if necessary.

Timer does not “catch up” to the programmed load state.  The 
load will remain in it’s state prior to entering the PGM mode.  
The timer will begin following the scheduled program at the next 
contrary ON/OFF time.

Load state doesn’t match programmed state immediately after 
programming the time or schedule.

Display shows  ‘no Op’.

Mechanism is inoperative.

If timer is in a very cold environment, try again when warmer.  
If not, and if the battery is good, the timer should be replaced.
Push in battery cover until you hear a click. Push reset button 
to clear display and reprogram the unit. Replace device if NoOp 
will not clear from display.

Make sure timer display shows ‘ON’ then check dimmer opera-
tion at full brightness setting.  If timer control is required at very 
low brightness settings, use a premium quality dimmer that can 
be turned on when set low.

Dimmer is turned off or is set too low to turn back on or the 
bulb is burned out.

Timer operates, but light doesn’t come on in dimmer applica-
tions.

Load only operates when the remote (3-way) switch is in one 
position or timer ignores the remote switch.

Remote switch is wired incorrectly.

Recheck  wiring,  especially  for  the  jumper,  per 

“Installation 

Instructions - 3-Way Switch” 

and 

“Other Installations”

.

Eliminate  condition,  replace  the  buried  cable,  do  without  the 
remote switch, or consult factory for other options.

Replace remote switch.

Excessive length of wire (greater than 30 feet) or buried wiring 
to the remote switch.

Remote switch is defective or worn out.

Timer  ignores  remote  (3-way)  switch  even  though  it  is  wired 
correctly.

REMEDY

POSSIBLE CAUSE

SYMPTOM

Battery holder is difficult to snap in place

Battery not seated in holder, holder misaligned, or contact tabs 
of holder are bent.

Line up tabs on bottom of holder with notches in timer housing 
when pushing in.  Straighten bent contact tabs.

Load turns off immediately after being turned on.

Remote  switch  or  timer  wired  incorrectly,  excessive  length  of 
wire  (greater  than  30’)  or  buried  wiring  to  remote  switch,  or 
defective timer.

If the problem persists with the red wire disconnected or with 
a  ‘remote’  switch  temporarily  connected  right  at  the  timer, 
replace the defective timer, otherwise try the above remedies.

Wiring diagram, 2 switch installation (3-way) using a single pole remote switch:

LINE

BLACK

TIMER

BLUE

RED

SINGLE POLE SWITCH

LOAD

NEUTRAL