Pool/Spa Underwater Lighting Application

INSTALLATION

  For field wiring information, please refer to the instructions attached to inside of front cover.

  •  Make sure that all unused taps (leads) are separately insulated. 
  •  Check voltage at lamp terminals after installation. It should be 12 ± 0.3 VAC.
 • Voltages above 12.3 VAC at the light may cause the internal safety fuse of the transformer to switch 
    off and on. To prevent this from happening follow chart below for correct voltage and wire 
  gauge 

selection.

2

Step 1

   Select power source by adding up Bulb Watts

Step 2

   Determine length of cable run(s)

Step 3

   Determine wire gauge needed to deliver needed power 

Step 4

   Connect cable to output tap of transformer given in table

Transformer Cable - Voltage Selection Chart

Length of Cable

50 W Transformer

10 ft

12 V

12 V

12 V

12 V

12 V

20 ft

13 V

12 V

12 V

12 V

12 V

30 ft

13 V

13 V

12 V

12 V

12 V

50 ft

14 V

13 V

13 V

12 V

12 V

75 ft

14 V

13 V

12 V

12 V

100 ft

14 V

13 V

13 V

12 V

125 ft

14 V

13 V

12 V

150 ft

14 V

13 V

13 V

175 ft

14 V

13 V

13 V

200 ft

13 V

13 V

250 ft

14 V

13 V

Wire Gauge (AWG)

#18*

#16

#14

#12

#10

* Minimum Gauge Cable
**Blank fields indicate conditions not suited for wiring

Because of our commitment to continuing research and improvements, Intermatic Incorporated reserves the right to make changes, without notice, in the specifications and material contained 

herein and shall not be responsible for any damages, direct or consequential, caused by reliance on the material presented.

INTERMATIC INCORPORATED,

 

LIBERTYVILLE, IL 60048

http://www.intermatic.com

LIMITED WARRANTY

Warranty service is available by either (a) returning the product to the dealer from whom the unit was purchased or (b) completing 
a warranty claim online at www.intermatic.com. This warranty is made by: Intermatic Incorporated, 1950 Innovation Way, Suite 
300, Libertyville, IL 60048. 

For additional product or warranty information go to: http://www.Intermatic.com or call 815-675-7000.

Summary of Contents for PX Series

Page 1: ...x 5 1 4 13 3 cm wide x 4 1 2 11 4 cm deep Mounting brackets top and bottom Enclosure Type PX50 0 048 corrosion resistant steel with electrostatically applied paint PX50S 0 036 Stainless Steel Knockouts Total of ten 1 2 3 4 combination 4 bottom 2 right side 2 left side 2 back 1 GENERAL INFORMATION If installation involves running wire through a building structure special wiring methods are needed D...

Page 2: ... V 12 V 12 V 50 ft 14 V 13 V 13 V 12 V 12 V 75 ft 14 V 13 V 12 V 12 V 100 ft 14 V 13 V 13 V 12 V 125 ft 14 V 13 V 12 V 150 ft 14 V 13 V 13 V 175 ft 14 V 13 V 13 V 200 ft 13 V 13 V 250 ft 14 V 13 V Wire Gauge AWG 18 16 14 12 10 Minimum Gauge Cable Blank fields indicate conditions not suited for wiring Because of our commitment to continuing research and improvements Intermatic Incorporated reserves...

Page 3: ...e de boîtier PX50 Acier résistant à la corrosion de 1 22 mm 0 048 po avec peinture appliquée électrostatiquement PX50S Acier inoxydable de 0 91 mm 0 036 po Alvéoles défonçables Total de dix alvéoles combinées de 1 2 po à 3 4 po 4 en bas 2 sur côté droit 2 sur côté gauche 2 au dos 3 GÉNÉRALITÉS Si l installation suppose le passage de câbles à travers la structure d un bâtiment des méthodes spéciale...

Page 4: ... Étape 2 Déterminer les longueurs de câbles individuels Étape 3 Déterminer le calibre de fil requis pour transporter le courant nécessaire Étape 4 Raccorder le câble à la sortie du transformateur indiquée dans le tableau CALIBRE DE MINIMUM DU CÂBLE LES CHAMPS VIDES CORRESPONDENT À DES CONDITIONS INADAPTÉES POUR LE CÂBLAGE GARANTIE LIMITÉE Ce service de garantie est disponible a en retournant le pr...

Reviews: