background image

PX SERIES LOW VOLTAGE

LANDSCAPE AND SWIMMING

POOL/SPA LIGHT TRANSFORMERS

INSTALLATION

OPERATION &

SERVICE MANUAL

Model: PX50 and PX50S - 50 W Transformers

INPUT: 120 VAC, 0.5 A Max, OUTPUT: 12, 13 or 14 VAC

Read and follow the safety instructions listed below and other basic safety precautions before installation or opera-

tion of this transformer and other associated equipment.

These Safety Transformers are specifically designed 

to supply 12 VAC to pool/spa lights, submersible 

fixtures and outdoor garden lights. The built-in 

circuit protection will disconnect power to the 

transformer in case of defect or overload. 

SPECIFICATIONS

Enclosure Size:

 7 

1

/

4

” (19.4 cm) high x 5 

1

/

4

” (13.3 

cm) wide 

x 4 

1

/

2

” (11.4 cm) deep. Mounting brackets top and 

bottom.

Enclosure Type: 

PX50 

- 0.048” corrosion resistant steel with 

electrostatically applied paint.

PX50S 

- 0.036” Stainless Steel.

Knockouts:

 Total of ten 

1

/

2

”-

3

/

4

” combination. 

(4) bottom, (2) right side, (2) left side, (2) back.

1

GENERAL INFORMATION

•  If installation involves running wire through a building structure, special wiring methods are needed.

•  Do Not submerge transformer.

•  Do Not exceed the maximum ratings of individual components, wiring devices, and current carrying capacity of conductors.

•  Select cable for each secondary output in accordance with tables in this manual.

•  Select power source by combining bulb wattage.

•   For landscape lighting appliances, low voltage cable shall be buried a maximum of 6 inches (15.2 cm) in order to connect to the 

main low voltage cable.

WARNING

Risk of Fire or Electrical Shock

Summary of Contents for PX Series

Page 1: ...x 5 1 4 13 3 cm wide x 4 1 2 11 4 cm deep Mounting brackets top and bottom Enclosure Type PX50 0 048 corrosion resistant steel with electrostatically applied paint PX50S 0 036 Stainless Steel Knockouts Total of ten 1 2 3 4 combination 4 bottom 2 right side 2 left side 2 back 1 GENERAL INFORMATION If installation involves running wire through a building structure special wiring methods are needed D...

Page 2: ... V 12 V 12 V 50 ft 14 V 13 V 13 V 12 V 12 V 75 ft 14 V 13 V 12 V 12 V 100 ft 14 V 13 V 13 V 12 V 125 ft 14 V 13 V 12 V 150 ft 14 V 13 V 13 V 175 ft 14 V 13 V 13 V 200 ft 13 V 13 V 250 ft 14 V 13 V Wire Gauge AWG 18 16 14 12 10 Minimum Gauge Cable Blank fields indicate conditions not suited for wiring Because of our commitment to continuing research and improvements Intermatic Incorporated reserves...

Page 3: ...e de boîtier PX50 Acier résistant à la corrosion de 1 22 mm 0 048 po avec peinture appliquée électrostatiquement PX50S Acier inoxydable de 0 91 mm 0 036 po Alvéoles défonçables Total de dix alvéoles combinées de 1 2 po à 3 4 po 4 en bas 2 sur côté droit 2 sur côté gauche 2 au dos 3 GÉNÉRALITÉS Si l installation suppose le passage de câbles à travers la structure d un bâtiment des méthodes spéciale...

Page 4: ... Étape 2 Déterminer les longueurs de câbles individuels Étape 3 Déterminer le calibre de fil requis pour transporter le courant nécessaire Étape 4 Raccorder le câble à la sortie du transformateur indiquée dans le tableau CALIBRE DE MINIMUM DU CÂBLE LES CHAMPS VIDES CORRESPONDENT À DES CONDITIONS INADAPTÉES POUR LE CÂBLAGE GARANTIE LIMITÉE Ce service de garantie est disponible a en retournant le pr...

Reviews: