background image

Wiring Diagrams

LOAD 4

LOAD 3

LOAD 2

LOAD 1

L1
L2/N

N

L3

L4

N

N

L6

L5

N

OUTPUT CONFIGURATION: IND - CIRCUIT 1 AND 2

OUTPUT CONFIGURATION: IND - CIRCUIT 3 AND 4

CIRCUIT 1

CIRCUIT 2

CIRCUIT 3

CIRCUIT 4

TIMER 

POWER

NO-4 COM4

COM3

NO-3

COM2

NO-2

COM1

NO-1

AC  IN

OUTPUT CONFIGURATION: SIM - CIRCUIT 1 AND 2

OUTPUT CONFIGURATION: SIM - CIRCUIT 3 AND 4

L1

L2

CIRCUIT 1

CIRCUIT 2

CIRCUIT 3

CIRCUIT 4

TIMER 

POWER

AC  IN

NO-1 COM1 NO-2 COM2 NO-3 COM3 NO-4 COM4

LOAD 1

LOAD 2

TIMER CONFIGURATION FOR TWO 208/240 VAC DPST

L1

L2/N

CIRCUIT 4

CIRCUIT 3

CIRCUIT 2

CIRCUIT 1

TIMER 

POWER

OUTPUT CONFIGURATION:PUL - CIRCUIT 1 AND 2 (BELL RINGING)

OUTPUT CONFIGURATION: SIM - CIRCUIT 3 AND 4 (208/240 VAC LOAD)

TIMER CONFIGURATION FOR COMBINATION MODE 

240VAC

LOAD1

COM4

NO-4

COM3

NO-3

COM2

NO-2

COM1

NO-1

AC  IN

4 - INDIVIDUAL 120/277 VAC LOADS

AC  IN

L2/N

L1

TIMER POWER

POWER TO TIMER

120/208/240/277 VAC

(AUTO VOLTAGE, NO JUMPERS REQUIRED)

LOAD 2

TIMER CONFIGURATION FOR TWO CONTACTOR CONTROLS

COM4

NO-4

COM3

NO-3

COM2

NO-2

COM1

NO-1

AC  IN

TIMER 

POWER

CIRCUIT 4

CIRCUIT 3

CIRCUIT 2

CIRCUIT 1

L2/N

L1

OUTPUT CONFIGURATION: PUL - CIRCUIT 1 AND 2

OUTPUT CONFIGURATION: PUL - CIRCUIT 3 AND 4

OPEN

CLOSE

COM

COM

CLOSE

OPEN

TIMER CONFIGURATION FOR COMBINATION MODE

LOAD 3

LOAD 2

LOAD 1

L1
L2/N

OUTPUT CONFIGURATION: SIM - CIRCUIT 1 AND 2 (208/240 VAC LOAD)

OUTPUT CONFIGURATION: IND - CIRCUIT 3 AND 4 (120/277 VAC LOAD)

CIRCUIT 1

CIRCUIT 2

CIRCUIT 3

CIRCUIT 4

TIMER 

POWER

NO-4 COM4

COM3

NO-3

COM2

NO-2

COM1

NO-1

AC  IN

L3 L5

N

L6

N

L7

AC  IN

NO-1 COM1 NO-2 COM2 NO-3 COM3

COM4

NO-4

TIMER 

POWER

CIRCUIT 4

CIRCUIT 3

CIRCUIT 2

CIRCUIT 1

OUTPUT CONFIGURATION: IND - CIRCUIT 1 AND 2 (120/277 VAC LOAD)

OUTPUT CONFIGURATION: SIM - CIRCUIT 3 AND 4 (208/240 VAC LOAD)

N

L4

L3

N

L2/N

L1

LOAD 1

LOAD 2

LOAD 3

L5 L6

TIMER CONFIGURATION FOR COMBINATION MODE

TIMER CONFIGURATION FOR COMBINATION MODE

OUTPUT CONFIGURATION: PUL - CIRCUIT 1 AND 2 (BELL RINGING)

OUTPUT CONFIGURATION: IND - CIRCUIT 3 AND 4

AC  IN

NO-1 COM1 NO-2 COM2 NO-3 COM3 NO-4 COM4

LOAD1

LOAD2

LOAD3

TIMER 

POWER

CIRCUIT 1

CIRCUIT 2

CIRCUIT 3

CIRCUIT 4

L2/N

L1

N

L3

N

L4

Summary of Contents for ET2745

Page 1: ...environment This equipment generates uses and radiates radio frequency energy and if not installed and used in accordance with instructions may cause harmful interference to radio communications Oper...

Page 2: ...the rear If a 3 4 inch knockout is needed remove the 1 2 inch knockout first then the 3 4 knockout 6 Place the enclosure in the desired location providing space for the enclosure door to swing open fu...

Page 3: ...ON FOR TWO CONTACTOR CONTROLS COM4 NO 4 COM3 NO 3 COM2 NO 2 COM1 NO 1 AC IN TIMER POWER CIRCUIT 4 CIRCUIT 3 CIRCUIT 2 CIRCUIT 1 L2 N L1 OUTPUT CONFIGURATION PUL CIRCUIT 1 AND 2 OUTPUT CONFIGURATION PU...

Page 4: ...te has not yet been entered the time switch will go to the Enter Date Mode Setting Date Follow this procedure below to set the date and time in the time switch NOTE If necessary hold or to scroll thro...

Page 5: ...o save Go to step 9 MON FRI Press DAY once and then press ENTER NEXT to save Go to step 9 SAT SUN Press DAY twice and then press ENTER NEXT to save Go to step 9 SET EACH DAY INDIVIDUALLY On the displa...

Page 6: ...day event to end 18 Press ON OFF buttons to remove each circuit not affected by this event All circuits are initially included with the event If the LOAD icon for the circuit is displayed then this ci...

Page 7: ...TXT where xx is the schedule number selected in the previous step 6 After the file is written REMOVE is shown on the display 7 Remove the USB memory stick and the time switch will advance to the next...

Page 8: ...o units caused by accident dropping or abuse in handling acts of God or any negligent use b units which have been subject to unauthorized repair opened taken apart or otherwise modified c units not us...