background image

Intermatic

©

 

Pg. 7

8V

IN

EXIT

ENTER

SCROLL

UP

SCROLL

DOWN

TAB

UP

TAB

DOWN

The Blue Box

TM

                       

Control Card

Online

RJ45

Lighting Contr

ol & Design

(800) 345-4448

Los Angeles, CA 

Bus  Connectors

no

phone

line

Bus Connector

A

B

+1

2

Gnd

Contact Closure Inputs

5v Gn

d

1 2 3 4 5 6

7 8 9 10 11 12 13 14

Terminator

Hand/Auto Switch

Zone

2

Zone

4

Zone

6

Zone

8

Zone

1

Zone

3

Zone

5

Zone

7

Assigns relays to a zone

Push "Assign" for 3  Seconds to check Mode

Assign

Button

Zones 1-8

Active

2

Zones 9-16

Active

4

6

8

10

Discrete

Mode

12

8 Zone

Mode

14

16 Zone

Mode

16

1

3

5

7

9

11

13

15

Optional Input

Address Assign

Input

+4.1

Photocell

Input

8

V

IN

The Blue Box

TM

Control Card

Online

RJ45

Lighting Contr

ol & Design

 

(800) 345-4448

  

Los An

geles, C

A

 

Bus  Connectors

no

n

one

e

pho

phone

line

ne

Bus Connector

A

B

+1

2

G

n

d

Contact Closure Inputs

5v G

n

d

1 2 3 4 5 6

7 8 9 1

0

1

1

12 1

3

1

4

Terminator

Hand

/

Auto Switc

h

Zone

2

Zone

4

Zone

6

Zone

8

Zone

1

Zone

3

Zone

5

Zone

7

Assigns re

lays to a zon

e

Push "Assi

gn" for 3  Seconds to check Mod

e

Assign

Button

g

Zones 1-8

Active

2

Zones 9-16

Active

4

6

8

10

Discrete

Mode

12

8 Zone

Mode

14

16 Zone

Mode

16

1

3

5

7

9

11

13

15

Optional Input

Address Assign

Input

+4.1

Ph

otoce

ll

In

put

Dual Voltage

Input Card

Power
Supply
Card

Xformer

Control Card

Smack

er Strip

Smack

er Strip

[R2]

[R4]

[R6]

[R8]

[R10]

[R12]

[R14]

[R16]

[R1]

[R3]

[R5]

[R7]

[R9]

[R11]

[R13]

[R15]

Modem

1

 

3

2

4

5

6

5

2

7

6

6

Internal Wiring Schematic 

Internal jumpers and cables for the EM1400 series 
are shown below. All jumpers and internal wiring con-
nections use depluggable connectors.

Gently tug a connector after connecting to ensure a 
firm fit and then visually inspect that the connector is 
seated squarely.

14-conductor ribbon cable supplies 5vdc, 
12vdc gnd, and 60 hz to the Control Card

10-conductor ribbon cable supplies con-
trol signal to each relay via the Smacker 
Strips

3#14 AWG supplies power and neutral 
to the transformer from the Dual Voltage 
Input Card.

3#18 AWG supplies power and reference 
Gnd to the Power Supply Card

2 conductor ribbon jumper supplies power 
to the relay coil which opens the relay 
contacts (NCL relays)

2#20AWG jumpers supply 24vac and 
Gnd to the Control Card and to the 
Smacker Strips

4#20AWG jumpers supply power and 
data from the Control Card to the (op-
tional) Modem.

1

2

3

4

5

6

7

Summary of Contents for EM1400 SERIES

Page 1: ...ing Schematic 7 Trouble Shooting 8 The EM1400 series is a programmable relay panel with 8 or 16 relays A master panel can stand alone or can control up to 16 digital devices photocell cards digital sw...

Page 2: ...iate lugs and Neutral and Ground as indicated 1 2 3 Do not power up the panel electronics until the bus has been activated see the Quick Start Guide You can check for faults while landing conductors o...

Page 3: ...ve the chassis from the enclosure Avoid rubbing the sides of the chassis against the enclosure Store the chassis in the original shipping case or any safe location until needed 1 2 3 4 1 2 Control of...

Page 4: ...orth Electronics Backplate Neutral Hot Relay 1 To Load Overview Line Low Voltage Connections The EM1400 digital bus allows up to 16 digital devices not including photo cells or contact closures device...

Page 5: ...s Contact Closure Inputs 14 programmable contact inputs can control any relay s in any panel s for manual on off or over ride Use shielded cable for distances over 150 feet Connect the drain wire to t...

Page 6: ...ramming Buttons in Master Panel only Scroll and tab to access control features for the system Assign Button Used to assign an address or change an existing address to the relay control card Zone Butto...

Page 7: ...ive 2 Zones 9 16 Active 4 6 8 10 Discrete Mode 12 8 Zone Mode 14 16 Zone Mode 16 1 3 5 7 9 11 13 15 Optional Input Address Assign Input 4 1 Photocell Input DualVoltage Input Card Power Supply Card Xfo...

Page 8: ...ss an override switch is acti vated the relay will turn off 1 1 1 2 2 2 3 3 Online Bus Connector A B 12 Gnd Hand Auto Switch Zone 2 Zone 4 Zone 6 Zone 8 Zone 1 Zone 3 Zone 5 Zone 7 Assigns relays to a...

Reviews: