Single Pole Application

Hot

Black

Neutral

Blue

Incandescent

Lighting Load

Red

Wire Connector

Ground

Green

120VAC

50/60 Hz

3-Way Application

Hot

Black

Neutral

Blue

Incandescent

Lighting Load

Red

Wire Connector

Ground

120VAC

50/60 Hz

Jumper

CA600

CA600

CA-3PS / Standard 3-Way Switch

Multi-Way Application

Hot

Black

Neutral

Blue

Incandescent

Lighting Load

Red

Wire Connector

Ground

120VAC

50/60 Hz

CA600

CA-3PS / Standard 3-Way Switch

CA-4PS / Standard 4-Way Switch

CA-3PS / Standard 3-Way Switch

CA-4PS / Standard 4-Way Switch

Green

Green

Wire Connector Installation

Connect wires per Single Pole, 3-Way, or Multi-Way 

Application Diagrams as follows:

Screw wire connectors on clockwise making sure no 
bare conductors show below the wire connector.  

Secure each connector with electrical tape.

Insert wires straight

then twist clockwise

Secure each connnector

with electrical tape

Maximum Load Per Dimmer for Multiple Devices

Cat. No.

CA600

Single

600 Watt

Two Devices

500 Watt

Three or More

400 Watt

For non-standard wiring applications, refer to

Wire Combination & Connector Chart

Orange Wire Connector Combination Chart

1- #14 AWG

1 #14 AWG

or

1 #16 AWG

or

1-2 #18 AWG

+

1- #16 AWG

1 #16 AWG

or

1-2 #18 AWG

+

2- #16 AWG

1 to 2 #18 AWG

+

1- #18 AWG

1 to 3 #18 AWG

+

Strip wires to expose

3/8” of conductors

3/8”

LIMITED TEN YEAR WARRANTY

If within ten (10) years from date of purchase, this product fails due to a defect in material or workmanship, Intermatic Incorporated will repair or replace, at 

its sole option. This warranty applies only to the original purchaser and is not transferable. This warranty excludes and this is disclaimed liability for labor for 

removal of this product or reinstallation. The warranty does not apply to: (a) damage caused by accident, abuse , mishandling, dropping, acts of God, or any 

negligent use; (b) units which have been subject to unauthorized repair, opened taken apart, or otherwise modified; (c) units not used in accordance with 

directions; (d) damages exceeding the cost of the procudt. Some states do not allow a limitation of damages, so the foregoing limitation may not app;y to you. 

This warranty gives you specific legal rights and you may have other rights that vary from state to state. 

INTERMATIC INCORPORATED WILL NOT BE 

LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS OR IMPLIED WARRANTIES. 

ALL IMPLIED WARRANTIES, INCLUDING THE WARRANTY OF MERCHANTABILITY AND THE WARRANTY OF FITNESS FOR A PARTICULAR 

PURPOSE, ARE HEREBY MODIFIED TO EXIST ONLY AS CONTAINED IN THIS LIMITED WARRANTY, AND SHALL BE OF THE SAME DURATION 

AS THE WARRANTY PERIOD STATED ABOVE.

This warranty service is available by either (a) returning the product to the dealer from whom the unit was purchased, or (b) mailing the product, along with 

proof of purchase, postage prepaid to the authorized service center listed below. This warranty is made by: Intermatic Incorporated/AfterSales Service 7777 

Winn Rd., Spring Grove, Illinois 60081-9698/815-675-7100  http://www.intermatic.com  Please be sure to wrap the product securely to avoid shipping damage.

158CA12471

158CA12471.indd   2

11/6/06   4:30:45 PM

Summary of Contents for CA600

Page 1: ...onventional 3 way or 4 way wiring and devices Lights fade up or down turned on or off Automatically returns to last level in the event of power fluctuations Light levels can be set by pressing and holding the rocker until the desired light level is reached Mini scenes allows local control of connected load plus up to 5 additional Z wave devices Full 230 device scene control when used with Intermat...

Page 2: ...ated will repair or replace at its sole option This warranty applies only to the original purchaser and is not transferable This warranty excludes and this is disclaimed liability for labor for removal of this product or reinstallation The warranty does not apply to a damage caused by accident abuse mishandling dropping acts of God or any negligent use b units which have been subject to unauthoriz...

Page 3: ...r de luz 3 Consulte los diagramas de cableado para conocer la conexión adecuada del atenuador para la aplicación objetivo 4 Compruebe que todas las conexiones de cable estén seguras 5 Coloque todos los cables dentro de la caja de empalme Instale el atenuador con dos 2 tornillos de montaje suministrados Complete la instalación con una placa de pared de decoración 6 Vuelva a conectar la energía eléc...

Page 4: ...gligente b unidades que hayan sido sometidas a una reparación no autorizada abiertas desmontadas o modificadas de alguna manera c unidades no utilizadas según las instrucciones d daños que excedan del costo del producto Algunos estados no permiten limitar los daños por lo que la limitación anterior pudiera no ser aplicable en su caso Esta garantía le otorga derechos legales específicos y puede ten...

Page 5: ...câblage pour les connexions appropriées du gradateur sur l application prévue 4 Vérifier que toutes les connexions sont bien faites 5 Placer tous les fils à l intérieur de la boîte de connexion Monter le gradateur à l aide des deux 2 vis de montage fournies Terminer l installation avec la plaque murale décorative 6 Reconnectez le courant électrique 7 Opération Basculer vers le haut pour allumer l ...

Page 6: ... ouverts démontés ou modifiés de quelconque manière c aux dispositifs qui ne sont pas utilisés conformément aux di rectives d aux dommages dépassant le coût du produit d aux dommages dépassant le coût du produit Certains états n autorisent pas l exclusion ou la limitation de dommages accidentels ou consécutifs dans tel cas les limites ci dessus ne s appliquent pas à vous Cette garantie vous accord...