If there is a fuel-burning appliance in more than one room and 
the number of alarms is limited, the following points should be 
considered when deciding where best to position the alarm: 

• 

Locate the alarm in a room containing a flueless or open-
flued appliance, and 

• 

Locate alarm in a room where the occupant(s) spend most 
time. 

If the domestic premises are a bedsit (a single room serving as 
both sitting and bedroom), then the alarm should be positioned 
as far from the cooking appliances as possible but near to 
where the person sleeps. 

If the appliance is in a room not normally frequented (for 
example a boiler room), the alarm should be positioned so that 
the alarm may be heard more easily. Alternatively, an 
interlinked alarm or a remote alarm siren may be connected to 
a type A alarm located in a room(s) containing a fuel-burning 
appliance. 

Where a fuel-burning appliance has an extended and/or 
concealed flue, an alarm should be installed in each room 
through which the flue passes. 

Room- fuel-burning appliance:

 Although carbon monoxide 

has a similar density to that of ambient air, it will normally be 
emitted as part of a warm gas mixture and will therefore tend to 
rise until it cools. If the alarm is located on a wall, it should be 
located close to the ceiling and at a height greater than the 
height of any door or window. 

Where an alarm is ceiling mounted, it should be at least 300 
mm from any wall, and where an alarm is wall-mounted, it 
should be at least 150 mm from the ceiling. The alarm should 
be at a horizontal distance of between 1 m and 3 m from the 
nearest edge of the potential source. 

If there is a partition in a room, the alarm should be located on 
the same side of the partition as the potential source. Carbon 
monoxide alarms in rooms with sloped ceilings should be 
located at the high side of the room. 

Sleeping rooms and in rooms remote from a fuel burning 
appliance: 

Alarms located in sleeping rooms and in rooms 

/areas, e.g. hallways, landings, remote from the fuel-burning 
appliance should be located relatively close to the breathing 
zone of the occupants. 

Figure 2: Recommended locations 

 

(1)  Dining 
(2)  Kitchen 
(3)  Bedroom 

(4)  Bedroom 
(5)  Living room 
(6)  Bedroom 

 

Locations to avoid 

Improper location can affect the sensitive electronic 
components in this alarm. To avoid causing damage to the 

unit, to provide optimum performance, and to prevent 
unnecessary nuisance alarms: 

• 

Do not install in kitchens, garages, or furnace rooms that 
may expose the sensor to substances that could damage 
or contaminate it. 

• 

Do not install in areas where the temperature is colder 
than 0

°C or hotter than +40°C such as crawl spaces, 

attics, porches, and garages. 

• 

Do not install within 1.5 m of heating or cooking 
appliances. We recommend 4.5 m to prevent nuisance 
alarms. 

• 

Do not install near vents, flues, chimneys, or any 
forced/unforced air ventilation openings. 

• 

Do not install on metal surfaces. 

• 

Avoid mounting in areas with a large quantity of metal or 
electrical wires. 

• 

Do not install near ceiling fans, doors, windows, or areas 
directly exposed to the weather. 

• 

Do not install in dead air spaces, such as peaks of vaulted 
ceilings or gabled roofs, where CO may not reach the 
sensor in time to provide early warning. 

• 

Do not install near deep-cell large batteries. Large 
batteries have emissions that can cause the alarm to 
perform at less than optimum performance. 

• 

Do not obstruct the vents located on the alarm. Do not 
place the alarm where drapes, furniture, or other objects 
block the flow of air to the vents. 

• 

Do not install directly above sink. Do not install in a damp 
or humid location or in the immediate vicinity of a cooking 
appliance. 

Battery installation and replacement 

Note: 

Place the control panel into sensor test mode prior to 

replacing the batteries. If the control panel is not in sensor test 
mode during battery replacement, an alarm/tamper condition 
may be indicated. 

To install or replace the batteries in this alarm: 

1.  Slide the alarm body off of the mounting plate. 

2.  If replacing batteries, remove the old batteries and 

properly dispose of them as recommended by the battery 
manufacturer. 

 

(1)

(2)

(3)

(4)

(5)

(6)

Summary of Contents for TX-6310-03-1

Page 1: ...larms It is intended for residential indoor dwelling unit applications It is not intended for use in industrial applications WARNING After ten years from initial power up this alarm will beep two times every 30 seconds to indicate that it is time to replace the alarm Replace the alarm immediately It will not detect CO in this condition To help identify the date to replace the alarm an area has bee...

Page 2: ...n rooms areas e g hallways landings remote from the fuel burning appliance should be located relatively close to the breathing zone of the occupants Figure 2 Recommended locations 1 Dining 2 Kitchen 3 Bedroom 4 Bedroom 5 Living room 6 Bedroom Locations to avoid Improper location can affect the sensitive electronic components in this alarm To avoid causing damage to the unit to provide optimum perf...

Page 3: ...mounted To mount the alarm 1 Slide the body off of the mounting plate Place the mounting plate in the desired location and mark the location of the two mounting holes Orient the mounting plate vertically or horizontally as shown in the following figures Figure 5 Vertical mounting Figure 6 Horizontal mounting 1 Mounting hole 2 Mounting latch 3 Alarm procedure label 4 Mounting hole 2 Insert the two ...

Page 4: ...the central monitoring station if you have a monitored system 1 Wait at least 10 minutes after installation to test the CO alarm 2 Make sure the green Power LED is flashing for normal operation 3 Set the control panel to sensor test mode 4 Press and hold the Test Hush button until the unit beeps two times approximately 5 seconds and then release the button If the unit is operating properly you wil...

Page 5: ...esentative UTC Fire Security B V Kelvinstraat 7 6003 DH Weert Netherlands Made in China Certification 0359 EN EN 50291 1 2010 Product warnings and disclaimers THESE PRODUCTS ARE INTENDED FOR SALE TO AND INSTALLATION BY QUALIFIED PROFESSIONALS UTC FIRE SECURITY CANNOT PROVIDE ANY ASSURANCE THAT ANY PERSON OR ENTITY BUYING ITS PRODUCTS INCLUDING ANY AUTHORIZED DEALER OR AUTHORIZED RESELLER IS PROPER...

Page 6: ...cially in cold weather It is therefore possible that outdoor conditions could be a factor in triggering domestic carbon monoxide alarms b There may be another source of carbon monoxide emission inducing the alarm for example a large amount of tobacco smoke town gas emission from a smouldering fire c The alarm may be induced by other substances Some sensors may respond to common household substance...

Page 7: ...u like symptoms 200 Dizziness and headache within 2 3 hours 400 Nausea frontal headache drowsiness confusion and rapid heart rate Risk to life after over 3 hours of exposure 800 Severe headache convulsions vital organ failure Death possible within 2 3 hours The relationship between the CO concentration and the duration of exposure can be calculated for a given COHb by parameterising the above fact...

Page 8: ...8 25 P N 3102145 ML REV F ISS 11MAR19 http www euro who int __data assets pdf_file 0020 123059 A QG2ndEd_5_5carbonmonoxide PDF Contact information For servicing or contact information see interlogix com ...

Page 9: ...ill silence the end of life signal for up to three days After three days the unit will resume end of life chirps Hush mode will silence the alarm ten times or up to 30 days After 30 days the unit can no longer be hushed Replace the CO alarm immediately The unit will not respond to CO Trouble service alarm Red Alarm LED flashes every 30 s One quick beep every 30 s Unit is in trouble condition Troub...

Page 10: ...ontiert werden Es wird empfohlen auf jeder Etage einen Melder zu installieren Achten Sie bei der Auswahl des Montageortes darauf dass der Melder von allen Schlafbereichen aus gehört werden kann Wenn Sie nur einen CO Melder in Ihrem Haus installieren montieren Sie ihn in der Nähe der Schlafzimmer nicht im Keller oder Heizungsraum Montieren Sie den Melder außerhalb der Reichweite von Kindern Kinder ...

Page 11: ...Fenstern oder Bereichen die dem Wetter ausgesetzt sind Installieren Sie den Melder nicht in stehenden Lufträumen wie Gewölbedecken oder Giebeln wo das CO den Melder nicht rechtzeitig erreicht Installieren Sie den Melder nicht in der Nähe von großen Deep Cell Batterien Autobatterien Große Akkus geben Emissionen ab die die Leistung des Melders beeinträchtigen können Bedecken Sie nicht die Lüftungsöf...

Page 12: ...ligen Einbruchmeldezentrale Anmelden des CO Melders im Funkempfänger der Einbruchmeldezentrale 1 Schalten Sie die Einbruchmeldezenttrale in den Programmiermodus 2 Rufen Sie das Menü Learn Add Sensors Melder einlernen hinzufügen auf 3 Wählen Sie die Nummer des gewünschten Melders 4 Lösen Sie den Wandsabotagekontakt aus indem Sie das Meldergehäuse von der Montageplatte nehmen 5 Wenn Sie die Einbruch...

Page 13: ...ittel verwendet werden Wenden Sie sich an Ihren lokalen Händler um eine CO Gasdose zu erhalten Solo C6 oder entsprechend 1 Warten Sie mindestens 10 Minuten nach der Installation um den CO Melder zu testen 2 Stellen Sie sicher dass die grüne Betriebs LED für den normalen Betrieb blinkt 3 Schalten Sie die Einbruchmeldezentrale in den Meldertestmodus 4 Drücken und halten Sie die Test Hush Taste bis d...

Page 14: ... JURISTISCHE PERSONEN DIE UNSERE PRODUKTE ERWERBEN SOWIE AUTORISIERTE HÄNDLER ODER AUTORISIERTE WIEDERVERKÄUFER ÜBER DIE ERFORDERLICHE QUALIFIKATION UND ERFAHRUNG VERFÜGEN UM BRANDSCHUTZ ODER SICHERHEITSTECHNISCHE PRODUKTE ORDNUNGSGEMÄSS ZU INSTALLIEREN Weitere Informationen zu Haftungsausschlüssen sowie zur Produktsicherheit finden Sie unter https firesecurityproducts com policy product warning o...

Page 15: ...in Innenräumen auftreten Beispielsweise könnte dies durch ein Fahrzeug in der Nähe oder bei starker Luftverschmutzung durch Verkehr bei kaltem Wetter eintreten Es könnte daher sein dass ein Kohlenmonoxidalarm im Innenraum durch äußere Umstände ausgelöst wird b Es gibt auch andere Quellen von Kohlenmonoxidemissionen die den Alarm auslösen können beispielsweise übermäßiger Tabakrauch Stadtgas Emissi...

Page 16: ...ichtszustand erreicht ist hängt von mehreren Faktoren ab z B die Lungenaktivität und die alveolare Kapillarübertragung kardiale Parameter die Hämoglobinkonzentration im Blut Luftdruck Sauerstoff und Kohlendioxidkonzentration in der eingeatmeten Luft die zwei wichtigsten Faktoren zur Ermittlung der COHb Konzentration sind jedoch die CO Konzentration und die Dauer der Einwirkung Die Wirkung verschie...

Page 17: ...los Dadurch wird der hörbare Piepton für 8 bis 11 Stunden ausgesetzt um die Batterien ungestört ersetzen zu können Anzeige für das Ende der Melder lebens dauer Rote Alarm LED blinkt zwei Mal alle 30 Sekunden Zwei schnelle Tonsignale alle 30 Sekunden Ende der CO Melderlebensdauer Störungs bedingung Störungston signal alle 60 Sekunden Drücken Sie die Test Hush Taste und lassen Sie sie los Dadurch wi...

Page 18: ... les systèmes de ventilation et d évacuation appropriés Emplacement du détecteur Les détecteurs de CO doivent être montés à l intérieur ou à proximité des chambres et des salles de séjour Nous vous recommandons d installer un détecteur à chaque étage de votre domicile Lorsque vous choisissez les lieux d installation assurez vous que vous pouvez entendre l alarme dans toutes les chambres à coucher ...

Page 19: ... ou d ouvertures de ventilation forcée non forcée Ne l installez pas sur des surfaces métalliques Évitez de placer l appareil dans des zones contenant une grande quantité de métal ou de fils électriques N installez pas le dispositif à proximité de ventilateurs de plafond de portes de fenêtres ou de zones directement exposées aux intempéries Ne l installez pas dans des espaces sans circulation d ai...

Page 20: ...a programmation reconnaissance de l unité dans la mémoire de la centrale Reportez vous à la documentation de la centrale pour obtenir des informations complètes sur la programmation Pour ajouter le détecteur de CO dans la mémoire de la centrale 1 Placez la centrale en mode de programmation 2 Accédez au menu Apprentissage Ajouter des détecteurs 3 Sélectionnez le numéro du détecteur souhaité 4 Décle...

Page 21: ... de CO solo C6 ou équivalent 1 Après l installation attendez au moins 10 minutes avant de tester le détecteur de CO 2 Assurez vous que le voyant d alimentation vert clignote pour indiquer un fonctionnement normal 3 Mettez la centrale en mode test du détecteur 4 Appuyez sur le bouton Test Silence et maintenez le enfoncé jusqu à ce que l unité émette trois bips environ 10 secondes puis relâchez le b...

Page 22: ...formations supplémentaires sur les garanties et la sécurité rendez vous à l adresse https firesecurityproducts com policy product warning ou scannez le code QR Directives européennes UTC Fire Security déclare par la présente que cet appareil est conforme aux exigences applicables et aux dispositions de toutes les règles et règlements applicables y compris mais sans s y limiter de la Directive 2014...

Page 23: ...déclenchement des alarmes de monoxyde de carbone domestiques b Une autre source d émission de monoxyde de carbone peut déclencher l alarme par exemple une grande quantité de fumée de tabac le gaz de ville l émission d un feu couvant c L alarme peut être déclenchée par d autres substances Certains détecteurs peuvent réagir aux substances domestiques communes telles que les solvants Les instructions...

Page 24: ...ion ppm Effets sur adultes 100 Légers maux de tête nausée fatigue symptômes pseudo grippaux 200 Étourdissements et maux de tête dans les 2 3 heures 400 Nausées maux de tête frontal somnolence confusion et fréquence cardiaque rapide Risque vital après plus de 3 heures d exposition 800 Maux de tête sévères convulsions défaillance d un organe vital Mort possible dans les 2 3 heures Le rapport entre l...

Page 25: ... bips rapides toutes les 30 s Fin de vie de l alarme de CO Condition de défaut Émission de bips de défaut toutes les 60 s Appuyez sur le bouton Test Silence puis relâchez le Le signal de fin de vie sera désactivé pendant trois jours Passé ce délai il sera réactivé Le mode silence désactivera l alarme dix fois ou 30 jours maximum Passé ce délai le signal ne pourra plus être désactivé Remplacez immé...

Reviews: