26
TVE-400/800-1600 H.264 IP Video Encoder User Manual
Under
Alarm Linking
check one of more of the desired the response
methods:
- Audible warning: Trigger an audible beep when an alarm is detected
- Notify surveillance center: Send a notification or alarm signal to remote
alarm host when an event occurs. The alarm host refers to the computer
installed with remote client software
- Send e-mail: Send an e-mail with alarm information to a user or users
when an event occurs.
Under
Trigger Alarm Output
select the channel to trigger an external alarm
output when a motion detection event occurs. See “To set up an alarm
output” below on how to set up an external alarm output.
Select the channel to trigger recording when a motion detection event occurs.
7. Click
Save
to save settings
.
To configure an alarm output:
1. Click
Device
Configuration
>
Alarm Settings
>
Alarm Output.
The Alarm
Output window appears.
2. Select an alarm output.
3. Select a time out option.
The time out setting lets you define how long a signal remains active after the
alarm has ended. Select a time out option: 5, 10, and 30 seconds, 1, 2, 5, and
10 minutes, and Manual clear. If “Manual clear” is selected, the alarm output
will stop only when the alarm input stops.
Summary of Contents for TVE-1200
Page 1: ...TVE 400 800 1600 H 264 IP Video Encoder User Manual P N 1072585C EN REV 1 0 ISS 16OCT12...
Page 4: ...ii TVE 400 800 1600 H 264 IP Video Encoder User Manual Specifications 43...
Page 13: ...TVE 400 800 1600 H 264 IP Video Encoder User Manual 9 Menu tree Figure 5 Encoder menu tree...
Page 50: ...46 TVE 400 800 1600 H 264 IP Video Encoder User Manual...