background image

2

TruPortal Input Expansion Board Quick Reference

Mounting the Enclosure

A TP-ADD-IO-BRD assembly can be installed into either a 
TruPortal System Controller enclosure, or a TP-ADD-IO or 
TP-ADD-IO-E enclosure. 

To install an TP-ADD-IO-BRD assembly into a TP-ADD-IO or 
TP-ADD-IO-E enclosure:

1.

Remove enclosure from shipping container and remove any 
packing material.

2.

Using the template provided (part number 531119001 or 
531120001), mark and then drill mounting holes.

3.

To mount on dry wall, use 1/8 in. (3.175 mm) hollow wall, 
expansion anchors. Unscrew the screws from the anchors. 
Mark the mounting holes. Force a starter hole in each mark 
with a sharp tool. Hammer the anchors into each hole. Align 
the box mounting holes over the anchor holes and screw in 
the anchors until tight.
To mount on a concrete surface, hold the enclosure on the 
mounting surface. Mark the mounting holes. Use a hammer 
drill with a 3/16 in. (4.76 mm) carb alloy drill bit and make 1-
in. (25.4 mm) deep holes in each marking. Insert a # 6-8 
plastic anchor in each hole and hammer them in. Use # 8 X 1 
in.(25.4 mm), Phillips, wood screws to screw into the plastic 
anchors and mount the enclosure.

4.

The enclosure includes standard cable knockouts on each 
side, including the back. Use the proper size and type of 
cable strain reliefs to secure cables to the enclosure.

Figure 1: TP-ADD-IO enclosure

Mounting the Module in the Enclosure

One TP-ADD-IN-BRD paired with exactly one TP-ADD-OUT-BRD 
can be installed inside the TruPortal System Controller enclosure. 
The universal mounting plate is not required in this case.

To install a TP-ADD-IO-BRD assembly into a TP-ADD-IO or 
TP-ADD-IO-E enclosure, determine the series of eight standoffs 
for mounting the module. Insert the module and mounting plate 
assembly, attaching it with the eight nuts provided.

Note:

Do not overtighten the mounting screws.

To mount the module in the AL400 enclosure using the 
mounting plate, se

Figure 3

 on page 3.

To mount the module in the AL600 enclosure using the 
mounting plate, se

Figure 4

 on page 3.

To mount the module in AL400 enclosure without the 
mounting plate, se

Figure 5

 on page 4.

To mount the module in AL600 enclosure without the 
mounting plate, se

Figure 6

 on page 4.

Callout

Description

1

Front view (cover not shown)

2

Bottom view; top view is the same.

3

Side view (typical)

4

0.20 in. (05 mm) and .38 in. (9.6 mm) double keyhole; 3 holes

5

Combination 1.125 in. (28.6 mm) and .875 in. (22.2 mm) 
knockout (typical)

Summary of Contents for TruPortal TP-ADD-IO-BRD

Page 1: ...system Packing List 16 input expansion board quantity 1 8 output relay expansion board quantity 1 Mounting plate depending on option ordered UL or CE enclosure with power supply depending on option ordered Installation kit which includes Two positional terminal plug in block quantity 2 Three positional terminal plug in block quantity 19 Four positional terminal plug in block quantity 1 End of line...

Page 2: ...anchors and mount the enclosure 4 The enclosure includes standard cable knockouts on each side including the back Use the proper size and type of cable strain reliefs to secure cables to the enclosure Figure 1 TP ADD IO enclosure Mounting the Module in the Enclosure One TP ADD IN BRD paired with exactly one TP ADD OUT BRD can be installed inside the TruPortal System Controller enclosure The univer...

Page 3: ... BRD Input Expansion board 2 TP ADD IO BRD Output Expansion board 3 28058B 02 mounting plate 4 TP ADD IO AL400 enclosure 5 6 32 SEMS nut 8 holes 6 6 32 x 38 in 9 652 mm screw 8 holes Callout Description 1 TP ADD IO BRD Input Expansion board 2 TP ADD IO BRD Output Expansion board 3 28058B 02 mounting plate 4 TP ADD IO AL600 enclosure 5 6 32 SEMS nut 8 holes 6 6 32 x 38 in 9 652 mm screw 8 holes ...

Page 4: ...n place if the rear tamper is not used 1 Remove the cap with the edge of a flat screwdriver 2 Discard the cap The tamper spring can now move freely through the bushing and make contact with the enclosure 3 Secure the enclosure to the mounting surface Callout Description 1 TP ADD IO BRD Input Expansion board 2 TP ADD IO BRD Output Expansion board 3 6 32 x 1 00 in 25 4 mm plastic standoff 4 holes 4 ...

Page 5: ... for the Input Expansion board can be passed through the SNAPP connection Optionally auxiliary power may be used to power the I O Expansion Module The 12 VDC auxiliary output at TB13 supports up to 10 mA Callout Description Callout Description 1 Terminal Block TB 7 TB10 inputs 9 TB13 Auxiliary power input 12 V 2 TB1 tamper off the wall 10 4 mounting holes 0 156 in 04 mm 3 SW1 front tamper switch e...

Page 6: ...ohm in parallel Outputs Two relay outputs Communication SNAPP VBUS Cable requirements 22 AWG 0 644 mm 0 326 mm2 stranded SNAPP bus four conductors VBUS three conductors Input wiring two conductors Power input two conductors Dimensions 5 75 x 2 875 x 0 6 in 146 x 73 x 15 mm Environmental Temperature 32 to 120 F 0 to 49 C Humidity 5 85 RHNC BTU output 4 1 BTU hour Certifications UL294 Listed FCC Par...

Reviews: